If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
| (5 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
__TOC__ | __TOC__ | ||
== Well Details == | == Well Details == | ||
| − | {| class="wikitable" width="95%" | + | {| class="wikitable welldetails" width="95%" |
| Well ID: 37-003-22111 | | Well ID: 37-003-22111 | ||
| − | | style=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.484261, -79.713103 | width=100% | height=100% }} |
| + | |- | ||
| + | | Country: United States | ||
| + | |- | ||
| + | | State: Pennsylvania | ||
| + | |- | ||
| + | | County: [[Allegheny_County,_Pennsylvania|Allegheny]] | ||
| + | |- | ||
| + | | Municipality: [[Plum Borough,_Allegheny_County,_Pennsylvania|Plum Borough]] | ||
|- | |- | ||
| Operator Name: [[PENNECO OIL CO INC]] | | Operator Name: [[PENNECO OIL CO INC]] | ||
|- | |- | ||
| − | | | + | | Well Pad ID: |
| + | |- | ||
| + | | Farm/Lease Name: CHEREP 5 | ||
| + | |- | ||
| + | | License Status: | ||
| + | |- | ||
| + | | Spud Date: | ||
|- | |- | ||
| − | | | + | | Permit Date: 2010-03-15 |
|- | |- | ||
| − | | | + | | Well Type: OIL |
|- | |- | ||
| − | | Unconventional: | + | | Unconventional Well: N |
|- | |- | ||
| − | | | + | | Configuration: Vertical Well |
|- | |- | ||
| − | | | + | | Conservation: No |
|- | |- | ||
| Latitude: 40.484261 | | Latitude: 40.484261 | ||
|- | |- | ||
| − | | Longitude: -79. | + | | Longitude: -79.713103 |
| + | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title = Permits Issued Detail Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
| + | | title = Spud Data Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-04-30 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
| + | | title = Oil and Gas Well Pad Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
| + | == Well History == | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Date | ||
| + | !scope="col" | Event | ||
| + | |- | ||
| + | | 2010-03-15 | ||
| + | | New Permit Application | ||
| + | |- | ||
| + | | 2010-04-12 | ||
| + | | Performed Spud Operation | ||
| + | |- | ||
| + | | 2010-04-19 | ||
| + | | Drilling Completion | ||
| + | |- | ||
| + | | 2010-04-27 | ||
| + | | Perforation | ||
| + | |- | ||
| + | | 2010-09-28 | ||
| + | | NEWLY DRILLED | ||
|- | |- | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
| + | | date = 2020-02-27 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2020-02-27 }}</ref> | ||
| + | <!--== Fracking Activities == | ||
| + | ==== Fracking Jobs ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Job Number | ||
| + | !scope="col" | Job Start Date | ||
| + | !scope="col" | Job End Date | ||
| + | !scope="col" | True Vertical Depth (ft) | ||
| + | !scope="col" | Total Water Volume (gal) | ||
| + | !scope="col" | Total Non-Water Volume (gal) | ||
| + | |- | ||
| + | |}--> | ||
| + | <!--==== Fluid Composition Data ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Job Number | ||
| + | !scope="col" | Trade Name | ||
| + | !scope="col" | Supplier | ||
| + | !scope="col" | Purpose | ||
| + | !scope="col" | Ingredient Name | ||
| + | !scope="col" | CAS Number | ||
| + | !scope="col" | Additive Percentage by Mass | ||
| + | !scope="col" | Job Percentage by Mass | ||
| + | !scope="col" | Mass Used (lb) | ||
| + | |- | ||
| + | |}--> | ||
| + | |||
| + | <!--== Stimulation Data == | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Stimulation Date | ||
| + | !scope="col" | Phase Number | ||
| + | !scope="col" | Chemical Agent | ||
| + | !scope="col" | Volume (gal) | ||
| + | !scope="col" | Treating Pressure (psi) | ||
| + | !scope="col" | Breakdown Pressure (psi) | ||
| + | |- | ||
| + | |}--> | ||
| + | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Operator Name |
| − | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
| − | !scope="col" | | + | !scope="col" | Gas Production Days |
| − | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
| − | !scope="col" | | + | !scope="col" | Oil Production Days |
| − | !scope="col" | OIL | + | !scope="col" | Water Quantity (bbl) |
| + | !scope="col" | Water Production Days | ||
| + | |- | ||
| + | | 2010 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 6,612.00 | ||
| + | | style="text-align: right;" | 214 | ||
| + | | style="text-align: right;" | 387.40 | ||
| + | | style="text-align: right;" | 214 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
| + | |- | ||
| + | | 2011 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 6,919.00 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 351.52 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2012 |
| − | | style="text-align:right;" | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 4,841.00 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 366 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 297.63 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 366 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2013 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 3,671.00 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 50.19 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2014 |
| − | | style="text-align:right;" | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 4,261.00 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 39.68 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2015 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 4,014.47 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 222.21 | ||
| + | | style="text-align: right;" | 61 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2016 |
| − | | style="text-align:right;" | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 3,974.89 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 366 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 94.67 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 31 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| + | | 2017 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 3,389.00 | ||
| + | | style="text-align: right;" | 337 | ||
| + | | style="text-align: right;" | 95.98 | ||
| + | | style="text-align: right;" | 337 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
| − | | | + | | 2018 |
| − | | style="text-align:right;" | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 4,103.38 |
| − | | style="text-align:right;" | 0.0 | + | | style="text-align: right;" | 365 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 83.56 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 31 |
| − | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
| + | | style="text-align: right;" | 0 | ||
| + | |- | ||
| + | | 2019 | ||
| + | | [[PENNECO OIL CO INC]] | ||
| + | | style="text-align: right;" | 3,966.17 | ||
| + | | style="text-align: right;" | 365 | ||
| + | | style="text-align: right;" | 58.82 | ||
| + | | style="text-align: right;" | 31 | ||
| + | | style="text-align: right;" | 0.00 | ||
| + | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title =Oil and Gas Production Reports | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-03-31 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Period |
| − | !scope="col" | | + | !scope="col" | Operator |
| − | !scope="col" | | + | !scope="col" | Waste Type |
| − | !scope="col" | | + | !scope="col" | Quantity |
| − | !scope="col" | | + | !scope="col" | Disposal Method |
| − | !scope="col" | | + | !scope="col" | Waste Facility ID |
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2010 | + | | 2010 |
| − | | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | Produced Fluid |
| − | + | | style="text-align: right;" | 25.00 Bbl | |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0091472 | | PA0091472 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2010 | + | | 2010 |
| − | | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | Drilling Fluid Waste |
| − | + | | style="text-align: right;" | 385.00 Bbl | |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0091472 | | PA0091472 | ||
| − | |||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | 2010 | + | | 2010 |
| − | | | + | | [[PENNECO OIL CO INC]] |
| − | | style="text-align:right;" | | + | | Fracing Fluid Waste |
| − | + | | style="text-align: right;" | 1,360.00 Bbl | |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0091472 | | PA0091472 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
| − | | | + | | 2011 |
| − | | | + | | [[PENNECO OIL CO INC]] |
| − | | | + | | Produced Fluid |
| − | | style="text-align:right;" | 25. | + | | style="text-align: right;" | 25.00 Bbl |
| − | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0095443 | | PA0095443 | ||
| − | |||
| − | |||
| − | |||
|- | |- | ||
|} | |} | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title =Oil and Gas Waste Reports | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-03-31 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
| + | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
| − | !scope="col" | | + | !scope="col" | Inspection ID |
| − | !scope="col" | | + | !scope="col" | Inspection Category |
| − | !scope="col" | | + | !scope="col" | Inspection Date |
| − | !scope="col" | | + | !scope="col" | Inspection Type |
| − | !scope="col" | | + | !scope="col" | Inspection Result |
| + | !scope="col" | Inspection Comments | ||
|- | |- | ||
| 1877536 | | 1877536 | ||
| + | | Primary Facility | ||
| 2010-04-15 | | 2010-04-15 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On April 15th, 2010 I conducted a routine inspection of the above site. Drilling was taking place at the time of the inspection. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The drilling pits looked to be in good condition and were well below the minimum 2' of freeboard. | | On April 15th, 2010 I conducted a routine inspection of the above site. Drilling was taking place at the time of the inspection. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The drilling pits looked to be in good condition and were well below the minimum 2' of freeboard. | ||
| − | |||
| − | |||
|- | |- | ||
| 1882813 | | 1882813 | ||
| + | | Primary Facility | ||
| 2010-04-20 | | 2010-04-20 | ||
| + | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| COMPLAINT #27065 NOISE AND SOAP IN THE AIR. THE RIG HAS MOVED FROM THIS SITE AND THERE IS NOT ANY SOAP IN THE PIT. | | COMPLAINT #27065 NOISE AND SOAP IN THE AIR. THE RIG HAS MOVED FROM THIS SITE AND THERE IS NOT ANY SOAP IN THE PIT. | ||
| − | |||
| − | |||
|- | |- | ||
| 1882829 | | 1882829 | ||
| + | | Primary Facility | ||
| 2010-04-19 | | 2010-04-19 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| DRILLING AT 3343'. ESTIMATED TD AT 3500'. | | DRILLING AT 3343'. ESTIMATED TD AT 3500'. | ||
| − | |||
| − | |||
|- | |- | ||
| 1882842 | | 1882842 | ||
| + | | Primary Facility | ||
| 2010-04-15 | | 2010-04-15 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| DAVE HILL DRILLING AT 1949'. 7' CASING TO BE SET AT 2109'. | | DAVE HILL DRILLING AT 1949'. 7' CASING TO BE SET AT 2109'. | ||
| − | |||
| − | |||
|- | |- | ||
| 1883344 | | 1883344 | ||
| + | | Primary Facility | ||
| 2010-04-30 | | 2010-04-30 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On April 30th, 2010 I conducted an inspection of the above site in response to several odor complaints. Drilling was completed at the time of the inspection. A swabbing rig was on site and likely the source of the odors. The frac pit had been recently constructed. The drilling pits looked to be in good condition. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. | | On April 30th, 2010 I conducted an inspection of the above site in response to several odor complaints. Drilling was completed at the time of the inspection. A swabbing rig was on site and likely the source of the odors. The frac pit had been recently constructed. The drilling pits looked to be in good condition. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. | ||
| − | |||
| − | |||
|- | |- | ||
| 1884491 | | 1884491 | ||
| + | | Primary Facility | ||
| 2010-04-28 | | 2010-04-28 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| RIG SET UP BAILING. E&S OK. | | RIG SET UP BAILING. E&S OK. | ||
| − | |||
| − | |||
|- | |- | ||
| 1884504 | | 1884504 | ||
| + | | Primary Facility | ||
| 2010-04-28 | | 2010-04-28 | ||
| + | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| COMPLAINT # 271010 FOR ODORS. RIG BAILING WELL CAUSING SOME ODORS. CREW WILL FINISH UP 4/29/10. | | COMPLAINT # 271010 FOR ODORS. RIG BAILING WELL CAUSING SOME ODORS. CREW WILL FINISH UP 4/29/10. | ||
| − | |||
| − | |||
|- | |- | ||
| 1884518 | | 1884518 | ||
| + | | Primary Facility | ||
| 2010-04-30 | | 2010-04-30 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| WELL SWABED. TUBING IN. RUNNING RODS. | | WELL SWABED. TUBING IN. RUNNING RODS. | ||
| − | |||
| − | |||
|- | |- | ||
| 1884575 | | 1884575 | ||
| + | | Primary Facility | ||
| 2010-04-22 | | 2010-04-22 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| SITE IS CLEAN, AND PIT LEVEL OK. SERVICE RIG ON SITE BUT NOT SET UP. | | SITE IS CLEAN, AND PIT LEVEL OK. SERVICE RIG ON SITE BUT NOT SET UP. | ||
| − | |||
| − | |||
|- | |- | ||
| 1894963 | | 1894963 | ||
| + | | Primary Facility | ||
| 2010-05-13 | | 2010-05-13 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| SITE IS GRADED AND PIT IS GONE.SITE NEEDS SEEDED.RODS IN NO JACK. | | SITE IS GRADED AND PIT IS GONE.SITE NEEDS SEEDED.RODS IN NO JACK. | ||
| − | |||
| − | |||
|- | |- | ||
| 1895036 | | 1895036 | ||
| + | | Primary Facility | ||
| 2010-06-15 | | 2010-06-15 | ||
| + | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| DRILLING COMPLETE.THERE NO JACK BUT TUBING AND RODS ARE IN. TANK IS SET AND DIKED.THE ACCESS ROAD IS STONED. | | DRILLING COMPLETE.THERE NO JACK BUT TUBING AND RODS ARE IN. TANK IS SET AND DIKED.THE ACCESS ROAD IS STONED. | ||
| − | |||
| − | |||
|- | |- | ||
| 1904613 | | 1904613 | ||
| + | | Primary Facility | ||
| 2010-07-09 | | 2010-07-09 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On July 9th, 2010 I conducted a routine inspection of the above site. Drilling had been completed and the well was in production. The pits have been closed and filled. The tanks were in place and a dike constructed around them. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The site was graded, seeded, and mulched. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. | | On July 9th, 2010 I conducted a routine inspection of the above site. Drilling had been completed and the well was in production. The pits have been closed and filled. The tanks were in place and a dike constructed around them. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The site was graded, seeded, and mulched. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. | ||
| − | |||
| − | |||
|- | |- | ||
| 1912623 | | 1912623 | ||
| + | | Primary Facility | ||
| 2010-08-02 | | 2010-08-02 | ||
| + | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| ODOR COMPLAINT #272590. SLIGHT CRUDE ODOR FROM TANK VENT. OPERATOR WILL INSTALL A CARBON FILTER. | | ODOR COMPLAINT #272590. SLIGHT CRUDE ODOR FROM TANK VENT. OPERATOR WILL INSTALL A CARBON FILTER. | ||
| − | |||
| − | |||
|- | |- | ||
| 1927308 | | 1927308 | ||
| + | | Primary Facility | ||
| 2010-10-05 | | 2010-10-05 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| OIL AND GAS WELL. SITE RESTORED. OIL TANK HAS A VAPOR FILTER. ALL WELL EQUIPTMENT IS FENCED. | | OIL AND GAS WELL. SITE RESTORED. OIL TANK HAS A VAPOR FILTER. ALL WELL EQUIPTMENT IS FENCED. | ||
| − | |||
| − | |||
|- | |- | ||
| 1947179 | | 1947179 | ||
| + | | Primary Facility | ||
| 2011-01-07 | | 2011-01-07 | ||
| + | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| OIL AND GAS WELL. TANKS WITH VAPOR FILTERS. EQUIPTMENT FENCED AND LOCKED. SITE AND ACCESS STONED. | | OIL AND GAS WELL. TANKS WITH VAPOR FILTERS. EQUIPTMENT FENCED AND LOCKED. SITE AND ACCESS STONED. | ||
| − | |||
|- | |- | ||
|} | |} | ||
| + | <!--==== Violations Commited ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Inspection ID | ||
| + | !scope="col" | Violation ID | ||
| + | !scope="col" | Violation Date | ||
| + | !scope="col" | Date Resolved | ||
| + | !scope="col" | Violation Code | ||
| + | !scope="col" | Violation Type | ||
| + | !scope="col" | Violation Comments | ||
| + | |- | ||
| + | |}--> | ||
| + | <!--==== Penalties Applied ==== | ||
| + | {| class="wikitable sortable" width="95%" | ||
| + | !scope="col" | Violation ID | ||
| + | !scope="col" | Penalty ID | ||
| + | !scope="col" | Penalty Code | ||
| + | !scope="col" | Penalty Status | ||
| + | !scope="col" | Penalty Date | ||
| + | !scope="col" | Enforcement Date | ||
| + | !scope="col" | Penalty Amount | ||
| + | !scope="col" | Amount Collected | ||
| + | |- | ||
| + | |}--> | ||
| + | For data sources see<ref>{{cite web | ||
| + | | title =Oil and Gas Compliance Report | ||
| + | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
| + | | date = 2019-05-20 | ||
| + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| + | | accessdate = 2019-05-21 }}</ref> | ||
==References== | ==References== | ||
| − | + | <references/> | |
| − | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
| + | [[Category:Pennsylvania Wells]] | ||
| Well ID: 37-003-22111 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.484261,"lon":-79.713103,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Allegheny | |
| Municipality: Plum Borough | |
| Operator Name: PENNECO OIL CO INC | |
| Well Pad ID: | |
| Farm/Lease Name: CHEREP 5 | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2010-03-15 | |
| Well Type: OIL | |
| Unconventional Well: N | |
| Configuration: Vertical Well | |
| Conservation: No | |
| Latitude: 40.484261 | |
| Longitude: -79.713103 |
| Date | Event |
|---|---|
| 2010-03-15 | New Permit Application |
| 2010-04-12 | Performed Spud Operation |
| 2010-04-19 | Drilling Completion |
| 2010-04-27 | Perforation |
| 2010-09-28 | NEWLY DRILLED |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2010 | PENNECO OIL CO INC | 6,612.00 | 214 | 387.40 | 214 | 0.00 | 0 |
| 2011 | PENNECO OIL CO INC | 6,919.00 | 365 | 351.52 | 365 | 0.00 | 0 |
| 2012 | PENNECO OIL CO INC | 4,841.00 | 366 | 297.63 | 366 | 0.00 | 0 |
| 2013 | PENNECO OIL CO INC | 3,671.00 | 365 | 50.19 | 365 | 0.00 | 0 |
| 2014 | PENNECO OIL CO INC | 4,261.00 | 365 | 39.68 | 365 | 0.00 | 0 |
| 2015 | PENNECO OIL CO INC | 4,014.47 | 365 | 222.21 | 61 | 0.00 | 0 |
| 2016 | PENNECO OIL CO INC | 3,974.89 | 366 | 94.67 | 31 | 0.00 | 0 |
| 2017 | PENNECO OIL CO INC | 3,389.00 | 337 | 95.98 | 337 | 0.00 | 0 |
| 2018 | PENNECO OIL CO INC | 4,103.38 | 365 | 83.56 | 31 | 0.00 | 0 |
| 2019 | PENNECO OIL CO INC | 3,966.17 | 365 | 58.82 | 31 | 0.00 | 0 |
For data sources see[5]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2010 | PENNECO OIL CO INC | Produced Fluid | 25.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
| 2010 | PENNECO OIL CO INC | Drilling Fluid Waste | 385.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
| 2010 | PENNECO OIL CO INC | Fracing Fluid Waste | 1,360.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
| 2011 | PENNECO OIL CO INC | Produced Fluid | 25.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
For data sources see[6]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 1877536 | Primary Facility | 2010-04-15 | Routine/Complete Inspection | No Violations Noted | On April 15th, 2010 I conducted a routine inspection of the above site. Drilling was taking place at the time of the inspection. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The drilling pits looked to be in good condition and were well below the minimum 2' of freeboard. |
| 1882813 | Primary Facility | 2010-04-20 | Complaint Inspection | No Violations Noted | COMPLAINT #27065 NOISE AND SOAP IN THE AIR. THE RIG HAS MOVED FROM THIS SITE AND THERE IS NOT ANY SOAP IN THE PIT. |
| 1882829 | Primary Facility | 2010-04-19 | Drilling/Alteration | No Violations Noted | DRILLING AT 3343'. ESTIMATED TD AT 3500'. |
| 1882842 | Primary Facility | 2010-04-15 | Drilling/Alteration | No Violations Noted | DAVE HILL DRILLING AT 1949'. 7' CASING TO BE SET AT 2109'. |
| 1883344 | Primary Facility | 2010-04-30 | Routine/Complete Inspection | No Violations Noted | On April 30th, 2010 I conducted an inspection of the above site in response to several odor complaints. Drilling was completed at the time of the inspection. A swabbing rig was on site and likely the source of the odors. The frac pit had been recently constructed. The drilling pits looked to be in good condition. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. |
| 1884491 | Primary Facility | 2010-04-28 | Drilling/Alteration | No Violations Noted | RIG SET UP BAILING. E&S OK. |
| 1884504 | Primary Facility | 2010-04-28 | Complaint Inspection | No Violations Noted | COMPLAINT # 271010 FOR ODORS. RIG BAILING WELL CAUSING SOME ODORS. CREW WILL FINISH UP 4/29/10. |
| 1884518 | Primary Facility | 2010-04-30 | Drilling/Alteration | No Violations Noted | WELL SWABED. TUBING IN. RUNNING RODS. |
| 1884575 | Primary Facility | 2010-04-22 | Drilling/Alteration | No Violations Noted | SITE IS CLEAN, AND PIT LEVEL OK. SERVICE RIG ON SITE BUT NOT SET UP. |
| 1894963 | Primary Facility | 2010-05-13 | Drilling/Alteration | No Violations Noted | SITE IS GRADED AND PIT IS GONE.SITE NEEDS SEEDED.RODS IN NO JACK. |
| 1895036 | Primary Facility | 2010-06-15 | Drilling/Alteration | No Violations Noted | DRILLING COMPLETE.THERE NO JACK BUT TUBING AND RODS ARE IN. TANK IS SET AND DIKED.THE ACCESS ROAD IS STONED. |
| 1904613 | Primary Facility | 2010-07-09 | Routine/Complete Inspection | No Violations Noted | On July 9th, 2010 I conducted a routine inspection of the above site. Drilling had been completed and the well was in production. The pits have been closed and filled. The tanks were in place and a dike constructed around them. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The site was graded, seeded, and mulched. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is reached. |
| 1912623 | Primary Facility | 2010-08-02 | Complaint Inspection | No Violations Noted | ODOR COMPLAINT #272590. SLIGHT CRUDE ODOR FROM TANK VENT. OPERATOR WILL INSTALL A CARBON FILTER. |
| 1927308 | Primary Facility | 2010-10-05 | Routine/Complete Inspection | No Violations Noted | OIL AND GAS WELL. SITE RESTORED. OIL TANK HAS A VAPOR FILTER. ALL WELL EQUIPTMENT IS FENCED. |
| 1947179 | Primary Facility | 2011-01-07 | Routine/Complete Inspection | No Violations Noted | OIL AND GAS WELL. TANKS WITH VAPOR FILTERS. EQUIPTMENT FENCED AND LOCKED. SITE AND ACCESS STONED. |
For data sources see[7]