{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.77397049,"lon":-81.29750594,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2015-02-20 | |
Unconventional: | |
Configuration: | |
Well Status: Drilling | |
Violations: 0 | |
Latitude: 39.77397049 | |
Longitude: -81.29750594 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1280431380 | 2015-05-19 | Status check inspection on the current drilling process found Patterson drilling rig 332 on the hole with the 9.625 2nd intermediate casing recently set to a depth of 7,564'. The company has ran in the hole with the directional drilling assembly and is preparing to begin drilling the 8.750 production borehole curve and lateral, a Formation Integrity Test will be performed on the casing shoe. | ||||
1424729509 | 2015-02-23 | The said well was spudded on 02/20/2015 and due to hole conditions a 36 x 40' liner string was set at surface, this was due to the well pad being a built on a old limestone quarry and the conductor hole collapsing. 02/23/2015 Express Energy's top hole rig is on location and as drilled a 32 x 94' conductor borehole and ran 94' of 26 conductor pipe. Express Energy cement service is on location to cement the casing using 330 sacks of class A-2% calcium .125 pps flake with 100% open hole cement excess ran and the cement water tested for chlorides and PH prior to cementing with good cement returns witnessed to surface. | ||||
156915331 | 2015-05-05 | Status check inspection to witness the cementing of the 369' of 18.625 surface casing inside a 24 borehole with CalFrac cement service on location to cement the casing using 616 sacks of class A-2% calcium .25 pps lcm cement with 50% open hole cement excess ran and circulation established prior to cementing with 6% gel ran ahead and good cement returns witnessed to surface with the casing pressure tested to 500 psi over lift pressure upon the landing of the cement plug. | ||||
-569941269 | 2015-05-12 | Status check inspection on the current drilling process found Patterson Drilling on location drilling the 12.250 2nd intermediate well bore section at a current depth of 5,204' and implementing a 15 degree borehole nudge in the direction of 73 degrees azimuth with the company using a tri cone drill bit and misting on air with a proposed total depth to be 7,540' for this section being drilled. | ||||
-849972733 | 2015-05-15 | Status check inspection on the current drilling process fount Patterson Drilling rig # 332 on location drilling the 12.250 2nd intermediate well bore section at a current depth of 7,486' with the company currently conditioning the hole on air. The current borehole position is 70.04 degrees azimuth with a 16 degree inclination. |