Well ID: 37-033-20012 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.065092,"lon":-78.716757,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Clearfield | |
Municipality: Brady Township | |
Operator Name: DOMINION ENERGY TRANS INC | |
Well Pad ID: | |
Farm/Lease Name: MILTON HARTZFELD N483 | |
License Status: Plugged OG Well | |
Spud Date: 1956-02-06 | |
Permit Date: | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Latitude: 41.065092 | |
Longitude: -78.716757 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2003 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2006 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2007 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2009 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | DOMINION ENERGY TRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | DOMINION ENERGY TRANS INC | Produced Fluid (in Barrels) RWC 802 | 71.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2543262 | Primary Facility | 2016-12-09 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection of Dominion’s Hartzfeld 1 well in Brady Twp. Clearfield County conducted December 9, 2016 at approximately 10 am. A rig is on location for plugging ops. I spoke with Mike Hoover w/ Windfall Oil & Gas to discuss operations to this point. CIBP was set @ 7080’ in the 7” csg. Original well record said 7” was cemented w/ 100 sks but stretch test on the 7” showed freepoint higher than expected (15” @ 105000lbs, calculated 2373’). They ran a bond log in the 7”, TOC at 1885’. A circulation squeeze on the backside must have been pumped at some time, not on any well records. Cementers set balanced plugs in the 7” cased hole yesterday. They WOC overnight, tagged last plug, pulling 7” today from 1852’. Til I left location they were two joints out the hole. Going forward they’ll set remaining plugs as outlined in the procedure; a balanced cement plug from inside the 7” csg stub back up the 8 ¾” openhole (1900’-1800’), a balanced cement plug across shallow gas interval in the open hole (1550’-1350’), (#3) balan |
2548102 | Primary Facility | 2016-12-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection of Dominion’s Hartzfeld 1 well in Brady Twp. Clearfield County conducted December 27, 2016 at 1:15 pm. The well had been plugged approximately 2 weeks ago. At the time of inspection; the well had a monument in place with a 2” vent pipe. I tied directly into the 2”; there was no pressure observed, no flow observed, and no gas in any amount was detected with an Altair 5x gas meter. No gas was detected outside the vent at ground level. No issues reported during plugging. No violations |
2553100 | Primary Facility | 2017-01-18 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine Inspection of a plugged gas well. There was a 2” candy cane vent pipe monument. I hooked up directly to the vent w/ 2” x ¼” reducer and pex fitting/hose directly to Altair 5x gas meter; No gas in any amount detected. No gas detected in any amount at ground level. No Violations. |
2691246 | Primary Facility | 2018-01-29 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a plugged gas well. There was a 2" candy cane vent pipe as a monument. No obvious issues were observed. |
2715535 | Primary Facility | 2018-04-04 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged, deep vertical well was conducted April 4, 2018. The well has a 2" candy cane vent with a well marker. No gas was detected in or around the vent, and no obvious issues were observed. |
380880 | Primary Facility | 1996-08-21 | Routine/Complete Inspection | No Violations Noted | INACTIVE; E&S OK |
For data sources see[6]