X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-033-20012

Well Details

Well ID: 37-033-20012
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Brady Township
Operator Name:
Well Pad ID:
Farm/Lease Name: MILTON HARTZFELD N483
License Status: Plugged and Abandoned
Spud Date: 1956-02-06
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.065092
Longitude: -78.716757

For data sources see[1][2][3]

Well History

Date Event
1956-02-06 Performed Spud Operation
1956-05-28 Drilling Completion
1956-07-17 Fully Plugged
2016-11-18 Begin Plugging
2016-12-12 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 Produced Fluid 71 Bbl CENT WASTE TRT FAC NPDES PA0095273
2016 DOMINION ENERGY TRANS INC Produced Fluid 71.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2543262 Primary Facility 2016-12-09 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Dominion’s Hartzfeld 1 well in Brady Twp. Clearfield County conducted December 9, 2016 at approximately 10 am. A rig is on location for plugging ops. I spoke with Mike Hoover w/ Windfall Oil & Gas to discuss operations to this point. CIBP was set @ 7080’ in the 7” csg. Original well record said 7” was cemented w/ 100 sks but stretch test on the 7” showed freepoint higher than expected (15” @ 105000lbs, calculated 2373’). They ran a bond log in the 7”, TOC at 1885’. A circulation squeeze on the backside must have been pumped at some time, not on any well records. Cementers set balanced plugs in the 7” cased hole yesterday. They WOC overnight, tagged last plug, pulling 7” today from 1852’. Til I left location they were two joints out the hole. Going forward they’ll set remaining plugs as outlined in the procedure; a balanced cement plug from inside the 7” csg stub back up the 8 ¾” openhole (1900’-1800’), a balanced cement plug across shallow gas interval in the open hole (1550’-1350’), (#3) balan
2548102 Primary Facility 2016-12-27 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Dominion’s Hartzfeld 1 well in Brady Twp. Clearfield County conducted December 27, 2016 at 1:15 pm. The well had been plugged approximately 2 weeks ago. At the time of inspection; the well had a monument in place with a 2” vent pipe. I tied directly into the 2”; there was no pressure observed, no flow observed, and no gas in any amount was detected with an Altair 5x gas meter. No gas was detected outside the vent at ground level. No issues reported during plugging. No violations
2553100 Primary Facility 2017-01-18 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine Inspection of a plugged gas well. There was a 2” candy cane vent pipe monument. I hooked up directly to the vent w/ 2” x ¼” reducer and pex fitting/hose directly to Altair 5x gas meter; No gas in any amount detected. No gas detected in any amount at ground level. No Violations.
2691246 Primary Facility 2018-01-29 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of a plugged gas well. There was a 2" candy cane vent pipe as a monument. No obvious issues were observed.
2715535 Primary Facility 2018-04-04 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this plugged, deep vertical well was conducted April 4, 2018. The well has a 2" candy cane vent with a well marker. No gas was detected in or around the vent, and no obvious issues were observed.
380880 Primary Facility 1996-08-21 Routine/Complete Inspection No Violations Noted INACTIVE; E&S OK

For data sources see[7]