If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-019-22579 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.75665,"lon":-79.800144,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Butler | |
Municipality: Jefferson Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: 151656 | |
Farm/Lease Name: WEST PAD 55 1H | |
License Status: | |
Spud Date: 2017-05-11 | |
Permit Date: 2016-10-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.756650 | |
Longitude: -79.800144 |
Date | Event |
---|---|
Deviated | |
2016-10-25 | New Permit Application |
2017-05-10 | Performed Spud Operation |
2017-08-17 | Drilling Completion |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-11-27 | 2017-12-07 | 6,246 | 12,353,300 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | PennEnergy Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.1285 | 103,728,000.0 |
Sand (Proppant) | Sargent | Proppant | Silica | 14808-60-7 | 99.9 | 10.3005 | 12,262,800.0 | |
Unihib G | GeoSafe | Acid Corrosion Inhibitor | Acetophenone | 98-86-2 | 1 | 0.00001082 | 12.883 | |
Methanol | 67-56-1 | 5 | 0.00005411 | 64.415 | ||||
Thiourea | 62-56-6 | 1 | 0.00001082 | 12.883 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00001082 | 12.883 | ||||
Glycol Ether | 112-34-5 | 60 | 0.000649284 | 772.981 | ||||
Ethoxylated Alcohol | 68002-97-1 | 35 | 0.000378749 | 450.905 | ||||
Hydrochloric Acid (7.5%) | Axiall | Acidizing | Hydrogen Chloride | 7647-01-0 | 40 | 0.966423 | 1,150,540.0 | |
Other Chemical(s) | Listed Above | See Trade Name(s) List | Ethylene Glycol | 107-21-1 | 5 | 0.000432587 | 515 | |
Ethoxylated Alcohol | 68002-97-1 | 35 | 0.000378749 | 450.905 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00237629 | 2829 | ||||
Acetophenone | 98-86-2 | 1 | 0.00001082 | 12.883 | ||||
Amine Triphosphate | Proprietary | 30 | 0.00259552 | 3090 | ||||
Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.0148814 | 17716.6 | ||||
Sodium Phosphate, Tribasic | 7601-54-9 | 5 | 0.000432587 | 515 | ||||
Sulfuric Acid | 7664-93-9 | 1 | 0.00000348 | 4.14 | ||||
Oxyalkylated Alcohol | Proprietary | 5 | 0.00248024 | 2952.76 | ||||
Alkyl Alcohol | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Thiourea | 62-56-6 | 1 | 0.00001082 | 12.883 | ||||
Methanol | 67-56-1 | 1 | 0.00007980 | 95 | ||||
Inorganic Salt | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Substitued Alkylamine | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Methanol | 67-56-1 | 5 | 0.00005411 | 64.415 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00001082 | 12.883 | ||||
TRS17888, TRS3001, BIOC12031A, TRS11800 | TightRock Solutions | Frac Fluid Additives | Hydrotreated Light Distillate | 64742-47-8 | 30 | 0.0148814 | 17716.6 | |
Inorganic Salt | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Ethylene Glycol | 107-21-1 | 5 | 0.000432587 | 515 | ||||
Oxyalkylated Alcohol | Proprietary | 5 | 0.00248024 | 2952.76 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00237629 | 2829 | ||||
Alkyl Alcohol | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Amine Triphosphate | Proprietary | 30 | 0.00259552 | 3090 | ||||
Methanol | 67-56-1 | 1 | 0.00007980 | 95 | ||||
Sodium Phosphate, Tribasic | 7601-54-9 | 5 | 0.000432587 | 515 | ||||
Substitued Alkylamine | Proprietary | 10 | 0.00496048 | 5905.52 | ||||
Breaker | Lubrizol | Breaker | Ammonium Peroxydisulfate | 7727-54-0 | 100 | 0.000347749 | 414 | |
Sulfuric Acid | 7664-93-9 | 1 | 0.00000348 | 4.14 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | PENNENERGY RESOURCES LLC | 4,125.00 | 3 | 0.00 | 0 | 0.00 | 0 |
2018 | PENNENERGY RESOURCES LLC | 1,197,896.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | PENNENERGY RESOURCES LLC | 816,215.00 | 359 | 0.00 | 0 | 0.00 | 28 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | PENNENERGY RESOURCES LLC | Other Oil & Gas Wastes | 636.33 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 241.67 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | PENNENERGY RESOURCES LLC | Other Oil & Gas Wastes | 707.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 410.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2017 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 235.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid | 2,841.74 Bbl | REUSE (AT WELL PAD) | |
2017 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 410.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2017 | PENNENERGY RESOURCES LLC | Drill Cuttings | 687.97 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Synthetic Liner Materials | 60.27 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Filter Socks | 0.09 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 41,508.29 Tons | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 28.73 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 35.33 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 10.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 5.54 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Servicing Fluid | 6.72 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 551.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 41.16 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 1,231.61 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 5,544.30 Bbl | REUSE (AT WELL PAD) | |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 37.19 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 258.61 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 518.59 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2593421 | Primary Facility | 2017-05-12 | Routine/Partial Inspection | No Violations Noted | |
2608938 | Primary Facility | 2017-06-29 | Drilling/Alteration | No Violations Noted | |
2608941 | Primary Facility | 2017-06-27 | Routine/Partial Inspection | No Violations Noted | |
2620387 | Primary Facility | 2017-07-06 | Routine/Partial Inspection | No Violations Noted | |
2629460 | Primary Facility | 2017-08-23 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, Patterson 259 is onsite on the 3H well. This well had production casing cemented using a lead 1 of 250 sxs (53 bbls) HalCem, 14.5 ppg, 1.2 yield, a lead 2 of 760 sxs (162 bbls) ShaleCem, 14.5 ppg, 1.2 yield and tail of 650 sxs (211 bbls) SoluCem, 15.2 ppg, 1.825 yield. Displaced with 229 bbls and bumped plug. Floats held (3.5 bbls back). 80 bbls of cement returned to surface. A float shoe and float collar were used along with 186 centralizers. |
2629532 | Primary Facility | 2017-08-15 | Drilling/Alteration | No Violations Noted | |
2645087 | Primary Facility | 2017-10-10 | Administrative/File Review | No Violations Noted | |
2668283 | Primary Facility | 2017-12-07 | Routine/Partial Inspection | No Violations Noted | On site for a routine partial inspection.
Post stimulation tear down and activity in progress. All temporary storage tanks, fuel storage, and portable generators, etc on containment. Well development pipeline being removed. Pad liner in place and intact. AST installed with containment. Gathering pipeline work continues. Pipeline header installed. E/S controls in place, intact, and functioning. Sound wall installed. Site has good vegetation growth. |
2670149 | Primary Facility | 2017-12-04 | Drilling/Alteration | No Violations Noted | At the time of inspection, Universal Well Services was onsite stimulating well. Notification was given that stage 17 of job communicated with Snyder Brothers' Concordia Lutheran Church 2-679 well. The Snyder well was shut in and is around 1000' from the wellbore of this well. There were no releases with the communication and integrity of both wells remain intact. Penn Energy and Snyder Brothers met and had an agreement on pumping pressures, which would be around 70 bbls/min.
Currently, stimulating stage 18. Unsure of total stages because some are not breaking down and may be re-perfed. |
2678361 | Primary Facility | 2018-01-04 | Administrative/File Review | No Violations Noted | |
2679437 | Primary Facility | 2018-01-04 | Routine/Complete Inspection | No Violations Noted | On 1/04/2018, WQS Brian MacQuarrie and WQSS Scott Lux onsite. Meet with Frank Kocher (Penn Energy subcontractor). Sandtraps setup at three wellheads. Large AST setup onsite for impaired water. Secondary containment maintained on well site. Snow on ground. No apparent violations. |
For data sources see[8]