== Well Details == | == Well Details == | ||
− | {| class="wikitable" width="95%" | + | {| class="wikitable welldetails" width="95%" |
| Well ID: 37-131-20228 | | Well ID: 37-131-20228 | ||
− | | style=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 41.571792, -75.972246 | width=100% | height=100% }} |
+ | |- | ||
+ | | Country: United States | ||
+ | |- | ||
+ | | State: Pennsylvania | ||
+ | |- | ||
+ | | County: [[Wyoming_County,_Pennsylvania|Wyoming]] | ||
|- | |- | ||
− | | | + | | Municipality: [[Tunkhannock Township,_Wyoming_County,_Pennsylvania|Tunkhannock Township]] |
|- | |- | ||
− | | | + | | Operator Name: [[CITRUS ENERGY CORP]] |
|- | |- | ||
− | | | + | | Well Pad ID: |
|- | |- | ||
− | | | + | | Farm/Lease Name: MCCONNELL UNIT MCCONNELL 1 1H |
|- | |- | ||
− | | | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
− | | | + | | Permit Date: 2011-11-14 |
|- | |- | ||
− | | | + | | Well Type: GAS |
|- | |- | ||
− | | | + | | Unconventional Well: Y |
+ | |- | ||
+ | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
| Latitude: 41.571792 | | Latitude: 41.571792 | ||
|- | |- | ||
| Longitude: -75.972246 | | Longitude: -75.972246 | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2011-11-14 | ||
+ | | New Permit Application | ||
|- | |- | ||
|} | |} | ||
− | + | For data sources see<ref>{{cite web | |
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | == Production Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Period | ||
+ | !scope="col" | Operator Name | ||
+ | !scope="col" | Gas Quantity (mcf) | ||
+ | !scope="col" | Gas Production Days | ||
+ | !scope="col" | Oil Quantity (bbl) | ||
+ | !scope="col" | Oil Production Days | ||
+ | !scope="col" | Water Quantity (bbl) | ||
+ | !scope="col" | Water Production Days | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[CITRUS ENERGY CORP]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Production Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | <!--== Waste Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
+ | !scope="col" | Waste Type | ||
+ | !scope="col" | Quantity | ||
+ | !scope="col" | Disposal Method | ||
+ | !scope="col" | Waste Facility ID | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
+ | !scope="col" | Inspection Comments | ||
|- | |- | ||
| 2032105 | | 2032105 | ||
+ | | Primary Facility | ||
| 2012-01-06 | | 2012-01-06 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2043450 | | 2043450 | ||
+ | | Primary Facility | ||
| 2012-02-17 | | 2012-02-17 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 2126269 | | 2126269 | ||
+ | | Primary Facility | ||
| 2012-12-11 | | 2012-12-11 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| During the inspection, I observed compromised liner integrity in several areas in the secondary containment liner were the frac tanks were stored. I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen areas of ponded water on the secondary containment liner. I recorded a conductivity reading of (2.46) milliSiemens/cm on the front side of the frac tanks relatively close to the corner of the Well Pad. This location would be the opposite side of the access road and corner of the Well Pad were the sediment traps are located below the fill slope. I did not record any elevated conductivity readings in any other areas of ponded water on the secondary containment liner. Majority of the readings indicated less than (500) microSiemens/cm. I also observed a petroleum like sheen relatively close to the area where I recorded the elevated conductivity reading mentioned above. I departed from the site at 11:45. | | During the inspection, I observed compromised liner integrity in several areas in the secondary containment liner were the frac tanks were stored. I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen areas of ponded water on the secondary containment liner. I recorded a conductivity reading of (2.46) milliSiemens/cm on the front side of the frac tanks relatively close to the corner of the Well Pad. This location would be the opposite side of the access road and corner of the Well Pad were the sediment traps are located below the fill slope. I did not record any elevated conductivity readings in any other areas of ponded water on the secondary containment liner. Majority of the readings indicated less than (500) microSiemens/cm. I also observed a petroleum like sheen relatively close to the area where I recorded the elevated conductivity reading mentioned above. I departed from the site at 11:45. | ||
− | + | |- | |
− | + | | 2260635 | |
− | | | + | | Primary Facility |
+ | | 2014-04-08 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | 2 producing wells on-site 131-20236 McConnell 1-2H & 131-20227 Francis 1H, 131-20228 McConnell 1-1H never drilled & permit expired, cellars empty, painting crew on-site, 8 empty frac tanks on-site ok, water in containment 65 millisiemens, water in puddle 227 millisiemens, Citrus rep on-site, all ok, no viols noted. | ||
|- | |- | ||
|} | |} | ||
− | == | + | <!--==== Violations Commited ==== |
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Violation ID |
− | !scope="col" | | + | !scope="col" | Violation Date |
− | !scope="col" | | + | !scope="col" | Date Resolved |
− | !scope="col" | | + | !scope="col" | Violation Code |
− | !scope="col" | | + | !scope="col" | Violation Type |
− | !scope="col" | | + | !scope="col" | Violation Comments |
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--==== Penalties Applied ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Violation ID |
− | + | !scope="col" | Penalty ID | |
− | + | !scope="col" | Penalty Code | |
− | + | !scope="col" | Penalty Status | |
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
− | |} | + | |}--> |
− | + | For data sources see<ref>{{cite web | |
− | + | | title =Oil and Gas Compliance Report | |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-05-20 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | + | | accessdate = 2019-05-21 }}</ref> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
− | + | <references/> | |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
+ | [[Category:Pennsylvania Wells]] |
Well ID: 37-131-20228 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.571792,"lon":-75.972246,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Tunkhannock Township | |
Operator Name: CITRUS ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: MCCONNELL UNIT MCCONNELL 1 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-11-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.571792 | |
Longitude: -75.972246 |
Date | Event |
---|---|
2011-11-14 | New Permit Application |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CITRUS ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2032105 | Primary Facility | 2012-01-06 | Routine/Complete Inspection | No Violations Noted | |
2043450 | Primary Facility | 2012-02-17 | Routine/Complete Inspection | No Violations Noted | |
2126269 | Primary Facility | 2012-12-11 | Routine/Complete Inspection | No Violations Noted | During the inspection, I observed compromised liner integrity in several areas in the secondary containment liner were the frac tanks were stored. I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen areas of ponded water on the secondary containment liner. I recorded a conductivity reading of (2.46) milliSiemens/cm on the front side of the frac tanks relatively close to the corner of the Well Pad. This location would be the opposite side of the access road and corner of the Well Pad were the sediment traps are located below the fill slope. I did not record any elevated conductivity readings in any other areas of ponded water on the secondary containment liner. Majority of the readings indicated less than (500) microSiemens/cm. I also observed a petroleum like sheen relatively close to the area where I recorded the elevated conductivity reading mentioned above. I departed from the site at 11:45. |
2260635 | Primary Facility | 2014-04-08 | Routine/Complete Inspection | No Violations Noted | 2 producing wells on-site 131-20236 McConnell 1-2H & 131-20227 Francis 1H, 131-20228 McConnell 1-1H never drilled & permit expired, cellars empty, painting crew on-site, 8 empty frac tanks on-site ok, water in containment 65 millisiemens, water in puddle 227 millisiemens, Citrus rep on-site, all ok, no viols noted. |
For data sources see[6]