== Well Details == | == Well Details == | ||
{| class="wikitable" width="95%" | {| class="wikitable" width="95%" | ||
− | | Well ID: | + | | Well ID: 37-131-20228 |
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.571792, -75.972246 | width=100% | height=100% }} | | style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.571792, -75.972246 | width=100% | height=100% }} | ||
|- | |- |
Well ID: 37-131-20228 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.571792,"lon":-75.972246,"icon":""}]} |
County: Wyoming | |
Municipality: Tunkhannock Township | |
Operator Name: CITRUS ENERGY CORP | |
First Permit Date: 2011-11-14 | |
Last Permit Date: 2011-11-14 | |
Spud Date: None | |
Unconventional: Yes | |
Horizontal: Yes | |
Violations: None | |
Latitude: 41.571792 | |
Longitude: -75.972246 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
2032105 | 2012-01-06 | No Violations Noted | ||
2043450 | 2012-02-17 | No Violations Noted | ||
2126269 | 2012-12-11 | No Violations Noted | During the inspection, I observed compromised liner integrity in several areas in the secondary containment liner were the frac tanks were stored. I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen areas of ponded water on the secondary containment liner. I recorded a conductivity reading of (2.46) milliSiemens/cm on the front side of the frac tanks relatively close to the corner of the Well Pad. This location would be the opposite side of the access road and corner of the Well Pad were the sediment traps are located below the fill slope. I did not record any elevated conductivity readings in any other areas of ponded water on the secondary containment liner. Majority of the readings indicated less than (500) microSiemens/cm. I also observed a petroleum like sheen relatively close to the area where I recorded the elevated conductivity reading mentioned above. I departed from the site at 11:45.
|
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|