34-007-24095

Well Details

Well ID: 34-007-24095
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Jefferson Township
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name: BAIRD DAVID
License Status: Producing
License Date: 1998-05-20
Spud Date: 1998-06-22
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 1998-06-27
Well Total Depth: 3347.00 ft
Configuration: Vertical
Latitude: 41.780000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1998-05-20 Proposed Formations:CLINTON, Issued Date:5/20/98, Expired Date:5/20/99 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1998-06-22 RBDMS Rec
Completed 1998-06-27 RBDMS Rec
Reached Total Depth 1998-06-27 RBDMS Rec
Completion Report Received 1998-12-09 RBDMS Rec
Construction Permit Expires 1999-05-20 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-01-22 3178 3194 19
3178 3194 19
3178 3194 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 25000 Gal 23700 200 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 MFC DRILLING INC 886.00 0.00 120
1999 MFC DRILLING INC 1255.00 0.00 365
2000 MFC DRILLING INC 1597.00 63.00 365
2001 MFC DRILLING INC 1302.00 54.00 365
2002 MFC DRILLING INC 1344.00 0.00 365
2003 MFC DRILLING INC 3048.00 0.00 365
2004 MFC DRILLING INC 1117.00 76.00 365
2005 MFC DRILLING INC 1126.00 0.00 365
2006 MFC DRILLING INC 1195.00 0.00 365
2007 MFC DRILLING INC 1664.00 0.00 365
2008 MFC DRILLING INC 1358.00 48.00 365
2009 MFC DRILLING INC 1092.00 0.00 365
2010 MFC DRILLING INC 1148.00 0.00 365
2011 MFC DRILLING INC 1034.00 0.00 365
2012 MFC DRILLING INC 970.00 37.00 366
2013 MFC DRILLING INC 957.00 0.00 365
2014 MFC DRILLING INC 811.00 0.00 365
2015 MFC DRILLING INC 808.00 0.00 365
2016 MFC DRILLING INC 645.00 44.00 365
2017 MFC DRILLING INC 1200.00 0.00 365
2018 MFC DRILLING INC 839.00 34.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 MFC DRILLING INC Brine 132 120
1999 MFC DRILLING INC Brine 356 365
2000 MFC DRILLING INC Brine 901 365
2001 MFC DRILLING INC Brine 72 365
2002 MFC DRILLING INC Brine 491 365
2003 MFC DRILLING INC Brine 285 365
2004 MFC DRILLING INC Brine 190 365
2005 MFC DRILLING INC Brine 267 365
2006 MFC DRILLING INC Brine 156 365
2007 MFC DRILLING INC Brine 229 365
2008 MFC DRILLING INC Brine 227 365
2009 MFC DRILLING INC Brine 137 365
2010 MFC DRILLING INC Brine 134 365
2011 MFC DRILLING INC Brine 234 365
2012 MFC DRILLING INC Brine 150 366
2013 MFC DRILLING INC Brine 160 365
2014 MFC DRILLING INC Brine 118 365
2015 MFC DRILLING INC Brine 186 365
2016 MFC DRILLING INC Brine 79 365
2017 MFC DRILLING INC Brine 201 365
2018 MFC DRILLING INC Brine 220 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-623275176 2007-10-31 0:00 PW No Violations
0623275176 2007-10-31 Production Wells No Violations no violations .
1554232364 2019-04-02 Production Wells No Violations At the time of my inspection the well is equipped with an electric pump jack unite. The production valves were open at well. The tank battery consisted of two 100 BBL production tanks, a mechanical separator, and one chart run with current chart. Valve was open to separator. There is a domestic line plumbed off the sales line with a meter and a drip bottle. Valve was open. An earthen dike surrounded the tank battery. The load line to the tanks production valve was secured with a plug. Proper identification was posted at the tank battery. The lease road was in stable condition. Production records are current.
iDIAN00097 1999-04-02 Preliminary Restoration No Violations
iDIAN000970 1999-4-2 0:00:0 PL No Violations

For data sources see[9]