{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.4,"lon":-81.92,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Athens | |
| Municipality: Bern Township | |
| Operator Name: HUFFMAN-BOWERS INC | |
| Well Pad ID: | |
| Farm/Lease Name: CURTIS CHARLES | |
| License Status: Producing | |
| License Date: 1974-02-13 | |
| Spud Date: 1974-02-19 | |
| Spud Drilling Contractor: | |
| Final Drill Date: 1974-03-25 | |
| Well Total Depth: 1453.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.400000 | |
| Longitude: -81.920000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| Unknown | 1802-01-01 | Issued Date 2/14/74 Expired Date Acres Tool Type Proposed Formation Proposed Depth Proposed Drill Depth |
| Original Spud | 1974-02-19 | C.S. |
| Completed | 1974-03-25 | C.S. |
| Reached Total Depth | 1974-03-25 | C.S. |
| Construction Permit Expires | 1975-02-14 | C.S. |
| CO | 1983-04-08 | 133 QUAKER STATE OIL REF CORP |
| CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate |
| Change of Owner | 1999-08-05 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 6351, T & C OIL & GAS COMPANY |
| Change of Owner | 2001-11-02 | Operator changed from 6351, T & C OIL & GAS COMPANY to 952, G-R CONTRACTING INC |
| Change of Owner | 2014-02-03 | Operator changed from 952, G-R CONTRACTING INC to 5155, HUFFMAN-BOWERS INC |
| Record Last Modified | 2014-02-03 | C.S. |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2006-09-11 | 1419 | 1427 | 2 |
| 1419 | 1427 | 2 | |
| 1419 | 1427 | 2 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| H2O | 0 | 1400 Bbl | 10000 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1985 | QUAKER STATE OIL REF CORP | 425.00 | 342.00 | 365 |
| 1986 | QUAKER STATE OIL REF CORP | 509.00 | 660.00 | 365 |
| 1987 | QUAKER STATE OIL REF CORP | 918.00 | 432.00 | 365 |
| 1988 | QUAKER STATE OIL REF CORP | 676.00 | 289.00 | 365 |
| 1989 | QUAKER STATE OIL REF CORP | 652.00 | 243.00 | 365 |
| 1990 | QUAKER STATE OIL REF CORP | 521.00 | 220.00 | 365 |
| 1991 | QUAKER STATE OIL REF CORP | 519.00 | 191.00 | 365 |
| 1992 | QUAKER STATE OIL REF CORP | 616.00 | 203.00 | 365 |
| 1993 | QUAKER STATE OIL REF CORP | 420.00 | 139.00 | 365 |
| 1994 | QUAKER STATE OIL REF CORP | 285.00 | 113.00 | 365 |
| 1995 | BELDEN & BLAKE CORPORATION | 110.00 | 157.00 | 69 |
| 1996 | BELDEN & BLAKE CORPORATION | 56.00 | 235.00 | 117 |
| 1997 | BELDEN & BLAKE CORPORATION | 287.00 | 882.00 | 266 |
| 1998 | BELDEN & BLAKE CORPORATION | 268.00 | 143.00 | 274 |
| 1999 | BELDEN & BLAKE CORPORATION | 139.00 | 60.00 | 132 |
| 2001 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
| 2002 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
| 2003 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
| 2004 | G-R CONTRACTING INC | 256.00 | 311.00 | 365 |
| 2005 | G-R CONTRACTING INC | 64.00 | 158.00 | 365 |
| 2006 | G-R CONTRACTING INC | 99.00 | 165.00 | 365 |
| 2007 | G-R CONTRACTING INC | 29.00 | 69.00 | 365 |
| 2008 | G-R CONTRACTING INC | 25.00 | 27.00 | 365 |
| 2009 | G-R CONTRACTING INC | 67.00 | 85.00 | 365 |
| 2010 | G-R CONTRACTING INC | 75.00 | 175.00 | 365 |
| 2011 | G-R CONTRACTING INC | 49.00 | 188.00 | 365 |
| 2012 | G-R CONTRACTING INC | 124.00 | 132.00 | 366 |
| 2013 | G-R CONTRACTING INC | 17.00 | 61.00 | 365 |
| 2014 | G-R CONTRACTING INC | 98.00 | 0.00 | 34 |
| 2015 | HUFFMAN-BOWERS INC | 90.00 | 0.00 | 365 |
| 2016 | HUFFMAN-BOWERS INC | 26.00 | 0.00 | 365 |
| 2017 | HUFFMAN-BOWERS INC | 1.00 | 29.00 | 365 |
| 2018 | HUFFMAN-BOWERS INC | 0.00 | 0.00 | 365 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1194445776 | 2018-3-16 0:00: | PW | No Violations | 0.50 |
| 001269i248 | 2000-12-28 | Production Wells | Violations Noted | An inspection of the well site revealed that the company has set a production tank on the well site, the production tank is only 26 ft from the well head , the separator is only 21 ft from the well and production tank is only 6 ft from the separator . THE PRODUCTION TANK AND SEPARATOR MUST BE AT LEAST 50 FT FROM THE WELL HEAD , AND 10 FT BETWEEN THE TANK AND SEPARATOR . |
| 001269i417 | 2001-10-04 | Production Wells | No Violations | Follow - up on NOV , In - Compliance. |
| 001269i995 | 2002-04-23 | Production Wells | No Violations | Follow-up on NOV, In-Compliance. |
| 005609i107 | 2001-03-21 | Production Wells | No Violations | A follow - up on NOV revealed Non - complaince , company has not moved production tank , separator from well site. Company had ask for an ext.till 3-16-01 from Dick Shockley , company has not complied with this NOV at this time. |
| 005609i140 | 2001-04-03 | Production Wells | No Violations | Follw - up on NOV , Non - Complaince , company has not removed the production tank or separator from the well site. The owner has had several chances to comply with the NOV. |
| 1108253947 | 2000-12-28 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1269i248 An inspection of the well site revealed that the company has set a production tank on the well site, the production tank is only 26 ft from the well head , the separator is only 21 ft from the well and production tank is only 6 ft from the separator . |
| 1194445776 | 2018-03-16 | Production Wells | No Violations | There was identification at the tank battery. The tank battery consisted of 1-210, 2-100 barrels, a knockout and a vertical separator. The well was equipped with a pumping unit, tubing, rods and an electric motor. |
| 1269i248 | 2000-12-28 0:00 | PW | No Violations | |
| 1269i417 | 2001-10-4 0:00: | PW | No Violations | |
| 1269i995 | 2002-4-23 0:00: | PW | No Violations | |
| 5609i107 | 2001-3-21 0:00: | PW | No Violations | |
| 5609i140 | 2001-4-3 0:00:0 | PW | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 001269i248 | US-OH-107330 | 2000-12-28 | Violation of tank spacing requirements | |
| 001269i248 | US-OH-107331 | 2000-12-28 | Violation of separator spacing requirements | |
| 001269i248 | US-OH-107332 | 2000-12-28 | No SPCC dike/or failure to keep dike free of water or oil | |
| 1108253947 | US-OH-102677 | 2000-12-28 | Violation of tank spacing requirements | |
| 1108253947 | US-OH-102678 | 2000-12-28 | Violation of separator spacing requirements | |
| 1108253947 | US-OH-102679 | 2000-12-28 | No SPCC dike/or failure to keep dike free of water or oil |