X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-009-23306

Well Details

Well ID: 34-009-23306
Loading map...
Country: United States
State: Ohio
County: Athens
Municipality: Bern Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: VERNON KENNETH
License Status: Producing
License Date: 1986-04-08
Spud Date: 1986-07-01
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1986-07-03
Well Total Depth: 760.00 ft
Configuration: Vertical
Latitude: 39.390000
Longitude: -81.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1986-04-08 Issued Date 4/8/86 Expired Date 4/8/87 Acres 0010000 Tool Type RTAF Proposed Formation MAXTON Proposed Depth 00760 Proposed Drill Depth 00760
Original Spud 1986-07-01 CHG CLASS 7-12-8
Completed 1986-07-03 CHG CLASS 7-12-8
Reached Total Depth 1986-07-03 CHG CLASS 7-12-8
CO 1986-07-04 369 FOUTS OPERATIONS INC GeoDate 4/8/86
Construction Permit Expires 1987-04-08 CHG CLASS 7-12-8
Completion Report Received 1987-04-24 CHG CLASS 7-12-8
CO 1989-06-27 2682 GLENEAYRE RESOURCES INC GeoDate 4/8/86
CO 1991-06-20 3969 KAPLAN INTERESTS INC GeoDate 4/8/86
Change of Owner 2004-07-08 Operator changed from 3969, KAPLAN INTERESTS INC to 7671, KEITO GAS INC
Change of Owner 2016-11-03 Operator changed from 7671, KEITO GAS INC to 9651, AM-TEK OIL INC
Last Compliance Report 2017-05-08 CHG CLASS 7-12-8
Record Last Modified 2017-05-08 CHG CLASS 7-12-8

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 760 765 0
760 765 0
760 765 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 NONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 GLENEAYRE RESOURCES INC 964.00 0.00 365
1988 GLENEAYRE RESOURCES INC 0.00 0.00 0
1990 GLENEAYRE RESOURCES INC 0.00 0.00 0
1992 KAPLAN INTERESTS INC 761.00 0.00 365
1993 KAPLAN INTERESTS INC 393.00 0.00 365
1994 KAPLAN INTERESTS INC 488.00 0.00 365
1995 KAPLAN INTERESTS INC 469.00 0.00 365
1996 KAPLAN INTERESTS INC 475.00 0.00 365
1997 KAPLAN INTERESTS INC 330.00 0.00 365
1998 KAPLAN INTERESTS INC 297.00 0.00 365
1999 KAPLAN INTERESTS INC 297.00 59.00 365
2000 KAPLAN INTERESTS INC 267.00 0.00 365
2001 KAPLAN INTERESTS INC 145.00 58.00 365
2002 KAPLAN INTERESTS INC 210.00 29.00 365
2003 KAPLAN INTERESTS INC 131.00 57.00 365
2004 KEITO GAS INC 26.00 0.00 180
2005 KEITO GAS INC 112.00 27.00 365
2006 KEITO GAS INC 73.00 6.00 365
2007 KEITO GAS INC 129.00 54.00 365
2008 KEITO GAS INC 132.00 39.00 365
2009 KEITO GAS INC 41.00 13.00 365
2010 KEITO GAS INC 73.00 28.00 365
2011 KEITO GAS INC 89.00 12.00 365
2012 KEITO GAS INC 67.00 0.00 366
2013 KEITO GAS INC 73.00 11.00 365
2014 KEITO GAS INC 21.00 7.00 365
2015 KEITO GAS INC 33.00 0.00 365
2016 AM-TEK OIL INC 104.00 0.00 92
2017 AM-TEK OIL INC 67.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 GLENEAYRE RESOURCES INC Brine 0 365
1988 GLENEAYRE RESOURCES INC Brine 0 0
1990 GLENEAYRE RESOURCES INC Brine 0 0
1992 KAPLAN INTERESTS INC Brine 0 365
1993 KAPLAN INTERESTS INC Brine 0 365
1994 KAPLAN INTERESTS INC Brine 0 365
1995 KAPLAN INTERESTS INC Brine 0 365
1996 KAPLAN INTERESTS INC Brine 0 365
1997 KAPLAN INTERESTS INC Brine 0 365
1998 KAPLAN INTERESTS INC Brine 0 365
1999 KAPLAN INTERESTS INC Brine 0 365
2000 KAPLAN INTERESTS INC Brine 0 365
2001 KAPLAN INTERESTS INC Brine 507 365
2002 KAPLAN INTERESTS INC Brine 619 365
2003 KAPLAN INTERESTS INC Brine 320 365
2004 KEITO GAS INC Brine 0 180
2005 KEITO GAS INC Brine 162 365
2006 KEITO GAS INC Brine 296 365
2007 KEITO GAS INC Brine 68 365
2008 KEITO GAS INC Brine 59 365
2009 KEITO GAS INC Brine 20 365
2010 KEITO GAS INC Brine 78 365
2011 KEITO GAS INC Brine 0 365
2012 KEITO GAS INC Brine 22 366
2013 KEITO GAS INC Brine 8 365
2014 KEITO GAS INC Brine 24 365
2015 KEITO GAS INC Brine 65 365
2016 KEITO GAS INC Brine 270
2017 AM-TEK OIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1014118395 2018-4-23 0:00: PW No Violations 0.30
-148394611 2018-3-20 0:00: PW No Violations 0.50
-1707200298 2018-3-27 0:00: PW No Violations 1.00
-1977670098 2017-3-7 0:00:0 PW No Violations 1.00
-373547900 2018-5-4 0:00:0 PW No Violations 0.40
-667726250 2006-12-7 0:00: AD No Violations
001269i916 2002-03-27 Annular Disposal No Violations Checked AD for Columbus.
0148394611 2018-03-20 Production Wells No Violations I spoke with Mr. Andrew Ulrich with Am-Tek Oil and he said that he was aware of the issues at the tank batteries and would get in her this weekend to get them corrected. That was last Friday when I spoke with him. The status of this well is the same as the day I inspected it. No remediation has taken place, the tank is still split and on location and the brine scalds are still visible with no attempts to resolve.
0373547900 2018-05-04 Production Wells No Violations Location has been remediated and violation is resolved.
0427769857 2017-03-07 Temporary Abandoned Annular Disposal No Violations This well was not equipped for annular disposal.
0667726250 2006-12-07 Annular Disposal No Violations The well was not equipped for annular disposal.
0740446154 2017-04-14 Production Wells No Violations Identification was posted correcting the compliance notice issued.
0812552840 2017-06-13 Production Wells No Violations Violation has been resolved.
1014118395 2018-04-23 Production Wells No Violations The brine scald outside of the dike is still present with no steps toward remediation taken. The tank that is leaking is still full of fluid. The brine that has leaked down the side of the tank and has crystalized. Pictures were taken.
1269i916 2002-3-27 0:00: AD No Violations
1332258076 2012-03-16 Annular Disposal No Violations Asked to check status of well by Columbus. Well not hooked up for annular disposal.
1653783129 2018-03-15 Production Wells Violations Noted I was informed of an issue of pollution and contamination today by my supervisors. I drove to the suspected location and found the information I was provided to be true. The dike contained a brine scald. There was brine and oily substances running down the side of the 50 barrel plastic tank, the source of which was a large crack/busted place in the side. There was a scalded area with copious amounts of deer tracks. There were two scalds outside of the dike as well. This will need remediated, both inside and outside. The contaminated soil inside and outside of the dike will need removed and disposed of properly. The location outside of the dike will then need seeded and mulched to prevent erosion. The tank will need emptied and removed from the tank battery as its integrity is compromised. The identification at the tank battery is illegible and will need corrected. The emergency contact numbers will also need to be correct. Pictures were taken of the location. I called Andrew Aulton on my way from the Zanesville office and his voicemail instructed me that the best way to get ahold of him is via texts. I sent him a text and informed him that I was made aware of two pollution and contamination issues at tank batteries above the Depue ERP field on Sandrock Rd. I explained that I was on my way to the locations and would be issuing violations. This was at 12:52 p.m.
1707200298 2018-03-27 Production Wells No Violations The tank with the crack that is seeping is still in place and still has fluid in it. The scalds are still visible with no obvious attempts to remediate them. The identification signs are still not corrected. I will call Andrew with Am-Tek today once I have better service.
1755840507 2018-04-05 Production Wells No Violations The tank with the split in the side is still full of liquid and still seeping. The dike is has water inside and the scald on the outside of the dike has not been remediated. The identification is still not legible.
1977670098 2017-03-07 Production Wells Violations Noted Inspection of this well found a gas well with a separator and a 100 barrel steel tank. There was no identification found at the wellhead there was an identification sign posted of the separator however it was illegible and contained the previous well owners name. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. If multiple wells are being produced into the common tank(s) each well-head shall be identified as to owner, permit number where available, well number and lease name.
427769857 2017-3-7 0:00:0 TD No Violations 1.00
740446154 2017-4-14 0:00: PW No Violations 1.00
812552840 2017-6-13 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1653783129 US-OH-116323 2018-05-18 9-1-07 Well operation causing pollution and contamination
1653783129 US-OH-116324 2018-05-18 9-9-05(A)10 Failure to legibly identify well
1653783129 US-OH-116325 2018-05-18 9-9-05(A)8 Equipment pressure rated below operating pressure
1653783129 US-OH-116326 2018-05-18 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil
1977670098 US-OH-119993 2017-03-13 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References