X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-009-23431

Well Details

Well ID: 34-009-23431
Loading map...
Country: United States
State: Ohio
County: Athens
Municipality: York Township
Operator Name: ODOT
Well Pad ID:
Farm/Lease Name: GARNER UNIT
License Status: Final Restoration
License Date: 2009-12-21
Spud Date: 1988-11-08
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1988-11-12
Well Total Depth: 3596.00 ft
Configuration: Vertical
Latitude: 39.430000
Longitude: -82.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-10-31 Issued Date 10/31/88 Expired Date 10/31/89 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03596 Proposed Drill Depth 03596
Original Spud 1988-11-08
Completed 1988-11-12
Reached Total Depth 1988-11-12
CO 1988-12-28 133 QUAKER STATE OIL REF CORP GeoDate 10/31/88
Completion Report Received 1989-03-01
Annular Disposal Well 1993-12-03
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 10/31/88
Unknown 1996-08-15 Issued Date 8/15/96 Expired Date 8/15/97 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1997-01-09 182 BELDEN & BLAKE CO GeoDate 10/31/88
CO 1997-01-09 5713 KLINE THURMAN OR MARLIN GeoDate 8/15/96
Revocation 1999-02-28
Last Compliance Report 2004-04-09
Change of Owner 2009-12-08 Operator changed from 5713, KLINE THURMAN OR MARLIN to 6130, O.D.O.T. - DIVISION 12
Change of Owner 2009-12-08 Operator changed from 6130, O.D.O.T. - DIVISION 12 to 8586, O.D.O.T.
APP 2009-12-21 Proposed Formations:CLINTON, Issued Date:12/21/2009, Expired Date:12/21/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2009-12-23
Construction Permit Expires 2010-12-21
Record Last Modified 2017-09-19

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-01-09 3425 3443 1
3425 3443 1
3425 3443 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 120000 Gal 0 RATE OF 43 BPM

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP 0.00 35.00 5
1989 QUAKER STATE OIL REF CORP 28126.00 2377.00 365
1990 QUAKER STATE OIL REF CORP 22150.00 1300.00 365
1991 QUAKER STATE OIL REF CORP 11318.00 455.00 365
1992 QUAKER STATE OIL REF CORP 5915.00 231.00 365
1993 QUAKER STATE OIL REF CORP 3432.00 92.00 365
1994 QUAKER STATE OIL REF CORP 1253.00 29.00 365
1995 BELDEN & BLAKE CORPORATION 833.00 0.00 123
1996 BELDEN & BLAKE CORPORATION 1024.00 0.00 133
1997 BELDEN & BLAKE CORPORATION 0.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP Brine 50 5
1989 QUAKER STATE OIL REF CORP Brine 730 365
1990 QUAKER STATE OIL REF CORP Brine 511 365
1991 QUAKER STATE OIL REF CORP Brine 402 365
1992 QUAKER STATE OIL REF CORP Brine 438 365
1993 QUAKER STATE OIL REF CORP Brine 394 365
1994 QUAKER STATE OIL REF CORP Brine 329 365
1995 BELDEN & BLAKE CORPORATION Brine 45 123
1996 BELDEN & BLAKE CORPORATION Brine 77 133
1997 BELDEN & BLAKE CORPORATION Brine 74 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1825597057 2010-5-4 0:00:0 FR No Violations 1.70
-897129093 2009-11-12 0:00 PW No Violations
0030500545 2009-12-23 Annular Disposal No Violations Well is plugged.
0858188197 2009-11-13 Production Wells No Violations Regarding discussion of ownership of this well and requirements to plug for new highway Rt. 33, ODOT is NOW telling Althiers Bros. That this well does not need plugged. Beaver Excavating originally told Althiers that it DID need plugged and was where road was coming thru - now they are saying ODOT doesnt need it plugged. Question is - well will be idle as was DM and they are tearing the house down - does ODOT own well as purchased in Warranty Deed to property, recorded Book 379, Page 2064? No mention of well in that recording but well is still in Klines name. Will work on getting well straightened out - Althiers say well is 50 from road - makes sense to plug now instead of later.
0897129093 2009-11-12 Production Wells No Violations Talked with Altiers Bros (Dale) - wanted me to meet with them regarding confusion on this well. Beaver Excavating says this is well that needs plugged in road right-of-- they call it Kline - progress should move forward now. Called Altiers again to explain, try it again.
1022507578 2009-12-17 Plug / Plug Back No Violations Inspection this day due to plugging - pulling rods, tubing this day.
1269i11750 2000-10-27 Production Wells No Violations Follow - up on NOV , In - Compliance. I.D. on well and tanks.
1269i11750454 2000-10-27 0:00 PW No Violations
1300545855 2009-12-18 Plug / Plug Back No Violations Witnessed the placement of tubing in well bore. It was determined that the approx location after installation was 5 below perforations. Instructed Plugging Contractor, Altier Bros., to install 1 more joint of tubing to achieve 50 below Clinton formation.
1657881932 2004-02-27 Annular Disposal No Violations The well is not equipped for annular disposal. No violations at the time of inspection.

Well Lat & Long update. Tank battery Lat & Long.

1825597057 2010-05-04 Final Restoration No Violations Inspection this day found location has been graded, level and clean. Vent pipe installed and well not leaking. No further reclamation required, per ODOT.
30500545 2009-12-23 0:00 AD No Violations
858188197 2009-11-13 0:00 PW No Violations

For data sources see[9]

References