Well Details

Well ID: 34-019-22736
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Center Township
Operator Name: PENNENERGY RESOURCES LLC
Well Pad ID: US-OH-000747
Farm/Lease Name: JENKINS UNIT
License Status: Producing
License Date: 2017-06-06
Spud Date: 2017-06-09
Spud Drilling Contractor: SIDEWINDER DRILLING INC
Final Drill Date: 2017-07-27
Well Total Depth: 15219.00 ft
Configuration: Horizontal
Latitude: 40.600000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-06-06 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:6/6/2017, Expired Date:6/6/2019 12:00:00 PM, Drilling unit acres:617.54, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2017-07-27 OP REQUEST 1 YEAR CONF ALL LOGS 9/22/17 ALE.
Correction to Well 2017-10-06 AS-
Completion Report Received 2018-01-23 OP REQUEST 1 YEAR CONF ALL LOGS 9/22/17 ALE.
Correction to Well 2018-03-09 UPDATE TAKE PER AS-DRILLED PLAT
Change of Owner 2018-10-03 Operator changed from 8894, R E GAS DEVELOPMENT LLC to 10212, PENNENERGY RESOURCES LLC
Record Last Modified 2019-01-09 OP REQUEST 1 YEAR CONF ALL LOGS 9/22/17 ALE.
Construction Permit Expires 2019-06-06 OP REQUEST 1 YEAR CONF ALL LOGS 9/22/17 ALE.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-02-05 8816 9012 55
2018-02-05 15043 15155 55
8816 9012 55
15043 15155 55
8816 9012 55

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/05/2017 11/22/2017 7669 10,557,200.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand ProFrac Proppant Silica Substrate 14808-60-7 100 11.7501 12,045,800.0
4.0 Gaur Slurry ProFrac Proppant Transport Distillates (petroleum), hydrotreated light 64742-47-8 45 0.00116 1194
Guar Gum 9000-30-0 55 0.00878 8998
ProFE 105 ProFrac Iron Control Citric Acid 77-92-9 40 0.00309 3167
Sulphamic Acid 5329-14-6 5 0.00039 396
Water 7732-18-5 70 0.01117 11452
Water Rex Energy Carrier/Base Water 7732-18-5 100 85.9738 88,099,800.0
ProSlick 900 ProFrac Friction Reducer Oleic Acid Diethanolamide 93-83-4 2 0.00024 249
copolymer of 2-propenamide 69418-26-4 30 0.00106 1082
Alcohols, C12-6 ethoxylated 68551-12-2 2 0.00024 249
Petroleum Distillate 64742-47-8 20 0.0007 721
Ammonium chloride (NH4)Cl) 12125-02-9 1 0.00012 124
Water 7732-18-5 45 0.00158 1623
Hydrochloric Acid (10%) Cooper Natural Acidizing Hydrochloric Acid (Hydrogen Chloride) 7647-01-0 28 0.60534 55223
Water 7732-18-5 72 1.55658 195789
Scaletrol 767W Baker Hughes Scale Inhibitor Organophosphonate 129828-36-0 15 0.00295 3023
Ammonium Chloride 12125-02-9 1 0.0002 202
Water 7732-18-5 75 0.01474 15115
Methanol 67-56-1 30 0.0059 6046
Other Chemical(s) Listed Above See Trade Name(s) List Mineral Oil 8042-47-5 5 0.00005000 50
Ammonium Chloride 12125-02-9 1 0.0002 202
Crystalline Silica: Quartz (SiO2) 14808-60-7 1 0.00001000 10
Heavy Aromatic Naphtha 64742-94-5 10 0.0001 100
Ethanol 64-17-5 2 0.00062 634
Olefin/Maleic Ester 68188-50-1 30 0.00029 300
Alkoxylate 9005-65-6 5 0.00013 133
Ammonium chloride (NH4)Cl) 12125-02-9 1 0.00012 124
Ethoxylated sorbitol tetraoleate 61723-83-9 5 0.00013 133
Glutaraldehyde 111-30-8 12.5 0.00387 3965
Chrystalline Silica: Cristobalite 14464-46-1 1 0.00001000 10
copolymer of 2-propenamide 69418-26-4 30 0.00106 1082
Hydrochloric Acid (Hydrogen Chloride) 7647-01-0 28 0.60534 55223
Sulphamic Acid 5329-14-6 5 0.00039 396
Diatomaceous Earth, Natural (kieselguhr) 61790-53-2 5 0.00005000 50
Organophosphonate 129828-36-0 15 0.00295 3023
Distillates (petroleum), hydrotreated light 64742-47-8 45 0.00116 1194
Quaternary Ammonium Compound 68424-85-1 1.8 0.00056 571
Naphthalene 91-20-3 1 0.00001000 10
Petroleum Distillate 64742-47-8 20 0.0007 721
Sodium Chloride 7647-14-5 5 0.00013 133
Distillates (petroleum), hydrotreated light 64742-47-8 15 0.00039 398
Poly(acrylamide-co-sodium acrylate) 25085-02-3 20 0.00052 531
Oleic Acid Diethanolamide 93-83-4 2 0.00024 249
Acetic acid etheynl ester, polymer with ethene 24937-78-8 5 0.00005000 50
Water 7732-18-5 85 0.657 6730
Citric Acid 77-92-9 40 0.00309 3167
Water 7732-18-5 40 0.00104 1062
Polyenthylene Glycol 25322-68-3 5 0.00013 133
Water 7732-18-5 75 0.01474 15115
Alcohols, C12-6 ethoxylated 68551-12-2 2 0.00024 249
Trimethylbenzenes 95-63-6 0.5 0 5
Alkyl Quatenary Compound 7173-51-5 1.2 0.00037 381
ProHib 100 ProFrac Acid Inhibitor Water 7732-18-5 85 0.657 6730
2-Polyn-1-ol compound w/ methyloxirane 38172-91-7 15 0.0002 206
Alpha 123 Baker Hughes Biocide Quaternary Ammonium Compound 68424-85-1 1.8 0.00056 571
Alkyl Quatenary Compound 7173-51-5 1.2 0.00037 381
Glutaraldehyde 111-30-8 12.5 0.00387 3965
Water 7732-18-5 82.5 0.02553 26167
Ethanol 64-17-5 2 0.00062 634
ParaSorb 5005 Baker Hughes Paraffin Inhibitor Heavy Aromatic Naphtha 64742-94-5 10 0.0001 100
Naphthalene 91-20-3 1 0.00001000 10
Chrystalline Silica: Cristobalite 14464-46-1 1 0.00001000 10
Trimethylbenzenes 95-63-6 0.5 0.00001000 5
Mineral Oil 8042-47-5 5 0.00005000 50
Calcined Diatomaceous Earth 91053-39-3 100 0.00098 100
Olefin/Maleic Ester 68188-50-1 30 0.00029 300
Diatomaceous Earth, Natural (kieselguhr) 61790-53-2 5 0.00005000 50
Acetic acid etheynl ester, polymer with ethene 24937-78-8 5 0.00005000 50
Crystalline Silica: Quartz (SiO2) 14808-60-7 1 0.00001000 10
FR 7010 ECM Friction Reducer Distillates (petroleum), hydrotreated light 64742-47-8 15 0.00039 398
Sodium Chloride 7647-14-5 5 0.00013 133
Ethoxylated sorbitol tetraoleate 61723-83-9 5 0.00013 133
Water 7732-18-5 40 0.00104 1062
Poly(acrylamide-co-sodium acrylate) 25085-02-3 20 0.00052 531
Alkoxylate 9005-65-6 5 0.00013 133
Polyenthylene Glycol Monooleate 9004-96-0 5 0.00013 133
Polyenthylene Glycol 25322-68-3 5 0.00013 133
ProBreak 100 ProFrac Oxidizer Ammonium Persulfate 7727-54-0 100 0.01596 16360

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2020-11-22 H2O 15 7296 Bbl 224550 PRO FRAC STAGE 1/35

STAGES 2-34 SEE IMAGES

2017-11-22 H2O 0 5519 Bbl 384600 PRO FRAC
2017-11-22 H2O 15 11660 Bbl 393540 PRO FRAC STAGE 35/35

STAGES 2-34 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 R E GAS DEVELOPMENT LLC 7602 686 4
2018 PENNENERGY RESOURCES LLC 495013 44791 350
2019 PENNENERGY RESOURCES LLC 80336 5742 89

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 R E GAS DEVELOPMENT LLC Brine 80 4
2018 PENNENERGY RESOURCES LLC Brine 3939 350
2019 PENNENERGY RESOURCES LLC Brine 263 89

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1298877362 2019-1-25 0:00: PW No Violations
-1750315875 2017-7-17 0:00: CS No Violations 8.00
-1902040537 2019-8-27 0:00: PW No Violations 0.80
-375749282 2020-4-2 0:00:0 PL No Violations 1.00
-451265088 2018-10-29 0:00 PW No Violations 1.00
0160079171 2017-07-19 Drill / Deepen / Reopen No Violations Sidewinder #62 was at a depth of 1025 and waiting on cementing after setting the intermediate casing at 5:30 AM. I spoke to the company man on site who informed me that no issues were encountered during drilling of the intermediate hole or cementing of the intermediate casing. I performed a walk-around inspection of the site and no violations were noted.
0451265088 2018-10-29 Production Wells No Violations No changes have been made to the production equipment since my last inspection. I performed a walk-around inspection of the pad and erosional controls appeared in place and functioning. The well was equipped with an open-flow assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production displayed approximately 680 psi.
0921900954 2018-12-28 Production Wells Violations Noted I was on site for a status check with DOGRM inspector John Fleming and Regional Supervisor Tom Hill. The well was equipped with an open-flow valve assembly. The surface/intermediate annular gauge displayed a reading of 48 psi. Identification posted at the access and well did not list the current owner of PennEnergy Resources. Records indicate that ownership of the well was transferred from R.E. Gas Development LLC to PennEnergy Resources on 10/03/2018. Per OAC: 9-9-05, any changes of ownership shall be shown on posted identification no later than sixty days after the date of transfer. The owner shall posted current identification to well and tank battery by 01/14/2019.
0982975649 2018-06-27 Production Wells No Violations I conducted a status check of the well and production pad. Six wells are located on the pad (permit numbers (22734, 22735, 22736, 24252, 24251, 24250). This well is equipped with an open-flow assembly. The surface-intermediate annulus was equipped with a pressure gauge and displayed a reading of zero psi. Identification was posted at the well and lease entrance. The production tanks and production equipment were surrounded by a lined steel dike. The access road was stable and drivable. Erosional controls appeared to be functioning.

Equipment on the pad consisted of the following: Nine 400 bbl production tanks; six labelled as containing condensate and four as containing produced water Six gas processing units with line heaters and vertical separators One combustor unit One vapor recovery unit One oil stabilization unit

1298877362 2019-01-25 Production Wells No Violations I was on site for a compliance notice follow-up for lack of updated identification. Proper identification was posted at the time of inspection. The surface/intermediate annular gauge displayed a reading of 60 psi and the intermediate/production annular gauge displayed 590 psi. No violations were observed at the time of inspection. The compliance notice can be closed.
1459441760 2019-9-9 0:00:0 PW No Violations 1.00
160079171 2017-7-19 0:00: DD No Violations
1750315875 2017-07-17 Casing String Witnessed No Violations

-55 grade, 54.5 lb/ft casing were ran into the hole, with twelve bow-

921900954 2018-12-28 0:00 PW No Violations 1.00
982975649 2018-6-27 0:00: PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0921900954 US-OH-130533 2019-03-18 9-9-05(A)10 Failure to legibly identify well