{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.64,"lon":-81.09,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Harrison Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: US-OH-001487 | |
Farm/Lease Name: GOEBELER UNIT | |
License Status: Producing | |
License Date: 2017-07-25 | |
Spud Date: 2017-08-11 | |
Spud Drilling Contractor: SIDEWINDER DRILLING INC | |
Final Drill Date: 2017-11-19 | |
Well Total Depth: 15286.00 ft | |
Configuration: Horizontal | |
Latitude: 40.640000 | |
Longitude: -81.090000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-07-25 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:7/25/2017, Expired Date:7/25/2019 12:00:00 PM, Drilling unit acres:590.06, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2017-11-19 | OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Correction to Well | 2018-01-19 | CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Change of Owner | 2018-10-03 | Operator changed from 8894, R E GAS DEVELOPMENT LLC to 10212, PENNENERGY RESOURCES LLC |
Completion Report Received | 2019-01-08 | OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Record Last Modified | 2019-05-23 | OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Construction Permit Expires | 2019-07-25 | OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-04-25 | 8034 | 8211 | 55 |
2018-04-25 | 15032 | 15222 | 55 |
8034 | 8211 | 55 | |
15032 | 15222 | 55 | |
8034 | 8211 | 55 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 03/01/2018 | 03/20/2018 | 7534 | 12,042,500.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Alpha 123 | Baker Hughes | Biocide | Ethanol | 64-17-5 | 2 | 0.000535234 | 630 |
Quarternary Ammonium Compound | 68424-85-1 | 1.8 | 0.000481711 | 567 | ||||
Water | 7732-18-5 | 82.5 | 0.0220856 | 25996 | ||||
Glutaraldehyde | 111-30-8 | 12.5 | 0.00334649 | 3939 | ||||
Alkyl Quaternary Compound | 7173-51-5 | 1.2 | 0.000321141 | 378 | ||||
Water | Rex Energy | Carrier/Base | Water | 7732-18-5 | 100 | 85.378 | 100,495,000.0 | |
ProFE 105 | ProFrac | Iron Control | Sulphamic Acid | 5329-14-6 | 5 | 0.000406948 | 479 | |
Citric Acid | 77-92-9 | 40 | 0.00325898 | 3836 | ||||
Water | 7732-18-5 | 70 | 0.00570322 | 6713 | ||||
FR 9400 | StimStream | Friction Reducer | Alcohols C10-16 | 68002-97-1 | 3.6 | 0.00250371 | 2947 | |
Ammonium acetate | 631-61-8 | 10 | 0.00695465 | 8186 | ||||
Alcohols C12-14 ethoxylated | 68439-50-9 | 3.6 | 0.00250371 | 2947 | ||||
Alcohols C12-16 ethoxylated | 68551-12-2 | 3.6 | 0.00250371 | 2947 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 25 | 0.0173866 | 20465 | ||||
ProBreak 100 | ProFrac | Oxidizer | Ammonium Persulfate | 7727-54-0 | 100 | 0.000327937 | 386 | |
ProHib 100 | ProFrac | Acid Inhibitor | Water | 7732-18-5 | 85 | 0.0192294 | 22634 | |
2-Polyn-1-ol compound w/ methyloxirane | 38172-91-7 | 15 | 0.00339322 | 3994 | ||||
Hydrochloric Acid (10%) | Cooper Natural | Acidizing | Hydrochloric Acid (Hydrogen Chloride) | 7647-01-0 | 28 | 0.633492 | 745654 | |
Water | 7732-18-5 | 72 | 1.62898 | 1,917,400.0 | ||||
FR 9200 | StimStream | Friction Reducer | Ethylene Glycol | 107-21-1 | 10 | 0.00002549 | 30 | |
Alcohols C12-15 ethoxylated | 120313-48-6 | 2 | 0.00000510 | 6 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 45 | 0.000112994 | 133 | ||||
FR 7005 | ECM | Friction Reducer | Sodium Chloride | 7647-14-5 | 10 | 0.00205088 | 2414 | |
Hydrotreated Petroleum Distillate | 64742-47-8 | 25 | 0.00512806 | 6036 | ||||
Alcohol Ethoxylate Surfactants | 68551-12-2 | 3 | 0.000615095 | 724 | ||||
Ammonium Chloride | 12125-02-9 | 2 | 0.000410346 | 483 | ||||
Polyoxyethylene Sorbitan Monooleate | 9005-65-6 | 1 | 0.000204748 | 241 | ||||
Water | 7732-18-5 | 50 | 0.010257 | 12073 | ||||
Oleic Acid Diethanolamide | 93-83-4 | 3 | 0.000615095 | 724 | ||||
Copolymer of 2-Propenamide | 69418-26-4 | 30 | 0.00615435 | 7244 | ||||
4.0 Guar Slurry | ProFrac | Proppant Transport | Guar Gum | 9000-30-0 | 55 | 0.0231638 | 27265 | |
Distillates (petroleum), hydrotreated light | 64742-47-8 | 45 | 0.0189524 | 22308 | ||||
Scaletrol 767W | Baker Hughes | Biocide | Water | 7732-18-5 | 75 | 0.016187 | 19053 | |
Methanol | 67-56-1 | 30 | 0.00647464 | 7621 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000215793 | 254 | ||||
Organophosphonate | 129828-36-0 | 15 | 0.00323689 | 3810 | ||||
Sand | ProFrac | Proppant | Silica Substrate | 14808-60-7 | 100 | 10.9185 | 12,851,700.0 | |
Other Chemical(s) | Listed Above | See Trade Name(s) List | Organophosphonate | 129828-36-0 | 15 | 0.00323689 | 3810 | |
Oleic Acid Diethanolamide | 93-83-4 | 3 | 0.000615095 | 724 | ||||
Hydrochloric Acid (Hydrogen Chloride) | 7647-01-0 | 28 | 0.633492 | 745654 | ||||
Sulphamic Acid | 5329-14-6 | 5 | 0.000406948 | 479 | ||||
4-Methoxyphenol | 150-76-5 | 0 | 0 | 0 | ||||
Ammonium acetate | 631-61-8 | 10 | 0.00695465 | 8186 | ||||
Ethylenediamineteraacetate, sodium salt | 64-02-8 | 0.1 | 0 | 0 | ||||
Ethylene Glycol | 107-21-1 | 10 | 0.00002549 | 30 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000215793 | 254 | ||||
Alcohols C10-16 | 68002-97-1 | 3.6 | 0.00250371 | 2947 | ||||
Polyoxyethylene Sorbitan Monooleate | 9005-65-6 | 1 | 0.000204748 | 241 | ||||
Hydrotreated Petroleum Distillate | 64742-47-8 | 25 | 0.00512806 | 6036 | ||||
Ammonium Chloride | 12125-02-9 | 2 | 0.000410346 | 483 | ||||
Water | 7732-18-5 | 85 | 0.0192294 | 22634 | ||||
Alkyl Quaternary Compound | 7173-51-5 | 1.2 | 0.000321141 | 378 | ||||
Alcohols C12-15 ethoxylated | 120313-48-6 | 2 | 0.00000510 | 6 | ||||
Copolymer of 2-Propenamide | 69418-26-4 | 30 | 0.00615435 | 7244 | ||||
Quarternary Ammonium Compound | 68424-85-1 | 1.8 | 0.000481711 | 567 | ||||
Alcohols C12-16 ethoxylated | 68551-12-2 | 3.6 | 0.00250371 | 2947 | ||||
Alcohols C12-14 ethoxylated | 68439-50-9 | 3.6 | 0.00250371 | 2947 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 45 | 0.0189524 | 22308 | ||||
Sodium Chloride | 7647-14-5 | 10 | 0.00205088 | 2414 | ||||
Glutaraldehyde | 111-30-8 | 12.5 | 0.00334649 | 3939 | ||||
Ethanol | 64-17-5 | 2 | 0.000535234 | 630 | ||||
Citric Acid | 77-92-9 | 40 | 0.00325898 | 3836 | ||||
Water | 7732-18-5 | 75 | 0.016187 | 19053 | ||||
Alcohol Ethoxylate Surfactants | 68551-12-2 | 3 | 0.000615095 | 724 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2018-03-01 | H2O | 10 | 8170 Bbl | 350782 | PRO FRAC | STAGE 1/41
STAGES 2-40 SEE IMAGES |
2018-03-20 | H2O | 10 | 6146 Bbl | 306640 | PRO FRAC | STAGE 41/41
STAGES 2-40 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | 527576 | 51058 | 264 |
2019 | PENNENERGY RESOURCES LLC | 117921 | 11826 | 89 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | Brine | 21073 | 264 |
2019 | PENNENERGY RESOURCES LLC | Brine | 2645 | 89 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1666068943 | 2018-1-16 0:00: | DD | No Violations | 1.20 |
-1671281196 | 2020-4-2 0:00:0 | PW | No Violations | 0.50 |
-1841980210 | 2018-6-30 0:00: | PW | No Violations | 2.50 |
-1955812359 | 2018-2-14 0:00: | PW | No Violations | 1.00 |
-2029376199 | 2018-4-25 0:00: | CT | No Violations | |
-466523992 | 2019-8-27 0:00: | PW | No Violations | 1.00 |
-661597071 | 2018-4-11 0:00: | DD | No Violations | 1.00 |
-798898381 | 2019-9-27 0:00: | PL | No Violations | 1.50 |
0377201670 | 2017-09-21 | Drill / Deepen / Reopen | No Violations | I was on site to check the drilling status of the pad. Sidewinder #62 was currently moving equipment on site and was anticipated to resume drilling operations this week. I performed a walk-around inspection of the site and no violations were noted at the time of inspection. |
0392593472 | 2018-01-04 | Drill / Deepen / Reopen | No Violations | I conducted a status check of the pad while the operator was in preparations to complete the well. Stacks were being set on the seven drilled wells while I was on site. I spoke to the consultant from Rex, who informed me that pressure testing for the well will take place during the weekend of 01/06/2018. I performed a walk-around inspection of the site and no violations were observed at the time of inspection |
0661597071 | 2018-04-11 | Drill / Deepen / Reopen | No Violations | I conducted a status check of the pad. Hydraulic fracturing operations on the pad were completed on 03/21/2018, and most equipment had been moved off site. Contractors were on site excavating and levelling the pad. Personnel were in the process of installing production equipment including oil stabilization units, producing tanks, and gas processing units, which are located on the north side of the A producing pad. |
0723310881 | 2017-08-14 | Drill / Deepen / Reopen | No Violations | I was on site with DOGRM Steve Ochs. The Yost#8 rig was in the process of being moved on site to drill the surface and intermediate sections of the seven permitted wells on the Goebeler B pad. We had a pre-spud meeting with Aaron Wilhite, the Rex consultant on site. Talking points included casing points and notifications. No violations were noted while at the time of inspection. |
0813291880 | 2017-09-14 | Drill / Deepen / Reopen | No Violations | |
0919327443 | 2018-01-10 | Drill / Deepen / Reopen | No Violations | I was on site to check the status of the pad. Schlumberger was on site running wireline logs, and a10k frac valve had been installed all seven wells. I spoke to the consultant on site, who anticipates completion activities to commence by the end of January. |
1385770085 | 2017-08-09 | Production Wells | No Violations | |
1666068943 | 2018-01-16 | Drill / Deepen / Reopen | No Violations | I was on site to pick up a copy of the bond logs ran on the seven Goebeler wells drilling during 2017. Rex was in the process of installing isolation valves on the stacks. I spoke to the company man who anticipated completion operations to commence during the week of 1/21/18. I performed a walk-around inspection of the pad and no violations were observed during the time of inspection. |
1841980210 | 2018-06-30 | Production Wells | No Violations
-around inspection of the pad perimeter and erosional controls appeared functioning. Production equipment consisted of the following: - 400 bbl production tanks, nine labeled as containing condensate, and nine as containing produced water Three vapor recovery units Four oil stabilization units with towers and vertical separators Ten gas processing units with vertical separators Seven combustor units I did not locate a surface-intermediate annular pressure gauge. I contacted operator who stated they in the process of acquiring gauges from the supplier and an annular gauge will be installed as soon as possible. | |
1955812359 | 2018-02-14 | Production Wells | No Violations | I was on site during completion operations. I performed a walk-around inspection of the site and no violations were observed at the time of inspection. |
2029376199 | 2018-04-25 | Completion Testing | No Violations | I was on site during flow back operations of the pad which started on 04/20/2018. Two stacks were actively flaring on the pad. I did not receive notification of flow back and subsequent flaring. I contacted Derek Smith of R.E. Gas Development and discussed notification requirements of flaring and informed the company that failure to do so in the future will result in enforcement action. |
377201670 | 2017-9-21 0:00: | DD | No Violations | |
392593472 | 2018-1-4 0:00:0 | DD | No Violations | 2.00 |
723310881 | 2017-8-14 0:00: | DD | No Violations | 1.00 |
813291880 | 2017-9-14 0:00: | DD | No Violations | 1.00 |
919327443 | 2018-1-10 0:00: | DD | No Violations | 1.00 |
For data sources see[10]