X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-26487

Well Details

Well ID: 34-031-26487
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Mill Creek Township
Operator Name: MILLER RUBEN D CLARS M
Well Pad ID:
Farm/Lease Name: BRENLY
License Status: Domestic Well
License Date: 1993-10-13
Spud Date: 1993-10-18
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1993-10-23
Well Total Depth: 3950.00 ft
Configuration: Vertical
Latitude: 40.430000
Longitude: -81.840000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1993-10-13 Issued Date 10/13/93 Expired Date 10/13/94 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03950 Proposed Drill Depth 03950
Original Spud 1993-10-18 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.
Completed 1993-10-23 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.
Reached Total Depth 1993-10-23 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.
CO 1994-01-27 4280 JRD ENERGY GeoDate 10/13/93
Completion Report Received 1994-02-14 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.
Construction Permit Expires 1994-10-13 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.
CO 1996-02-20 1084 KILLBUCK OILFIELD SERVICE GeoDate 10/13/93
Change of Owner 2014-10-03 Operator changed from 1084, KILLBUCK OILFIELD SERVICE to 9344, YODER JONATHAN,NAOMI,DAVID&BET
Change of Owner 2016-12-08 Operator changed from 9344, YODER JONATHAN,NAOMI,DAVID&BET to 9819, MILLER RUBEN D CLARS M
Record Last Modified 2016-12-08 CHANGED STATUS FROM PR TO DM PER TRANSFER FROM KILLBUCK OILFIELD SERVICE, LTD TO OWNER 10/3/2014 CM.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3810 3908 0
3810 3908 0
2006-09-11 3873 3882 9
3847 3856 8
3810 3908 0
2006-09-11 3847 3856 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 20000 FRAC W/1800 BW & 200 SX SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 JRD ENERGY 0.00 0.00 0
1994 JRD ENERGY 10534.00 0.00 365
1995 JRD ENERGY 5391.00 69.00 365
1996 JRD ENERGY 872.00 0.00 365
1997 KILLBUCK OILFIELD SERVICE 2593.00 45.00 365
1998 KILLBUCK OILFIELD SERVICE 1460.00 0.00 365
1999 KILLBUCK OILFIELD SERVICE 1040.00 0.00 365
2000 KILLBUCK OILFIELD SERVICE 910.00 0.00 365
2001 KILLBUCK OILFIELD SERVICE 100.00 0.00 365
2002 KILLBUCK OILFIELD SERVICE 100.00 0.00 365
2003 KILLBUCK OILFIELD SERVICE 40.00 0.00 365
2004 KILLBUCK OILFIELD SERVICE 131.00 0.00 365
2005 KILLBUCK OILFIELD SERVICE 100.00 0.00 365
2006 KILLBUCK OILFIELD SERVICE 100.00 0.00 365
2007 KILLBUCK OILFIELD SERVICE 100.00 0.00 365
2008 KILLBUCK OILFIELD SERVICE 100.00 5.00 365
2009 KILLBUCK OILFIELD SERVICE 300.00 5.00 365
2010 KILLBUCK OILFIELD SERVICE 200.00 5.00 365
2011 KILLBUCK OILFIELD SERVICE 100.00 9.00 365
2012 KILLBUCK OILFIELD SERVICE 100.00 9.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 JRD ENERGY Brine 140 0
1994 JRD ENERGY Brine 218 365
1995 JRD ENERGY Brine 0 365
1996 JRD ENERGY Brine 0 365
1997 KILLBUCK OILFIELD SERVICE Brine 125 365
1998 KILLBUCK OILFIELD SERVICE Brine 0 365
1999 KILLBUCK OILFIELD SERVICE Brine 0 365
2000 KILLBUCK OILFIELD SERVICE Brine 0 365
2001 KILLBUCK OILFIELD SERVICE Brine 0 365
2002 KILLBUCK OILFIELD SERVICE Brine 1 365
2003 KILLBUCK OILFIELD SERVICE Brine 0 365
2004 KILLBUCK OILFIELD SERVICE Brine 0 365
2005 KILLBUCK OILFIELD SERVICE Brine 0 365
2006 KILLBUCK OILFIELD SERVICE Brine 0 365
2007 KILLBUCK OILFIELD SERVICE Brine 0 365
2008 KILLBUCK OILFIELD SERVICE Brine 0 365
2009 KILLBUCK OILFIELD SERVICE Brine 0 365
2010 KILLBUCK OILFIELD SERVICE Brine 0 365
2011 KILLBUCK OILFIELD SERVICE Brine 0 365
2012 KILLBUCK OILFIELD SERVICE Brine 0 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1869232609 2006-3-8 0:00:0 PW No Violations
-701200310 2016-11-15 0:00 EX No Violations 1.50
0000009557 Preliminary Restoration No Violations PASSED Y WITNESSED 11/16/94 INSPECTOR DATE 11/1619/94 DATA FROM OLD VAX INFO
0000009558 Preliminary Restoration No Violations PASSED Y WITNESSED 8/29/94 INSPECTOR DATE 08/2919/94 DATA FROM OLD VAX INFO
0584784639 2005-12-08 Production Wells Violations Noted Well in production .
0701200310 2016-11-15 Exempt Well Pre Transfer No Violations On the day of my inspection I found that the well was equipped with a 4.5 to 2 inch swage that was plumbed to a vertical drip bottle, through a regulator, and into 2 inch plastic yellow gas line. The original steel flow line was disconnected at the wellhead. The gauge before the regulator showed 125 psi. The gauge after the regulator showed 12 psi. The valve to the gas line was open. There was a 1000 gallon reinforced poly tank staged near the wellhead. There were no leaks or spills around the wellhead. There was no identification posted at the wellhead. I found where the gas line exited the ground into a 1 inch steel line, through another regulator and into the cabin. The valve was open to the cabin. This well is no longer connected to the tank battery that was once shared with permit 3312. I spoke with Joseph Miller who claimed that they were using the well for domestic gas in the cabin.
0759507345 2005-08-16 Production Wells No Violations Well in production . Well needs identified .
1088871153 2008-10-29 Production Wells No Violations Pumping unit disconnected from well head . Valves are open on well head , may still be selling gas .
1397062146 2014-04-09 Exempt Well Pre Transfer No Violations On the day of my inspection I found that the well was shut in. The pumping unit has been removed and the production casing was equipped with a 4 to 2 swedge and a ball valve. The well is within reasonable proximity to a newly constructed cabin to be used for domestic gas. There were no leaks or spills around the well. This well shares a tank battery with permit 3312. There was no identification posted for this well.
1869232609 2006-03-08 Production Wells No Violations Follow up inspection . Well head identified .
584784639 2005-12-8 0:00: PW No Violations
759507345 2005-8-16 0:00: PW No Violations
9557 PL No Violations
9558 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0584784639 US-OH-126571 2005-12-08 Failure to legibly identify well

For data sources see[9]

References