If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-27170 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.23,"lon":-82.14,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Pike Township | |
Operator Name: LBJ DRILLING CO INC | |
Well Pad ID: | |
Farm/Lease Name: TANSKI | |
License Status: Producing | |
License Date: 2011-10-04 | |
Spud Date: 2011-10-19 | |
Spud Drilling Contractor: H & D DRILLING | |
Final Drill Date: 2011-10-29 | |
Well Total Depth: 3250.00 ft | |
Configuration: Vertical | |
Latitude: 40.230000 | |
Longitude: -82.140000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-10-04 | Proposed Formations:CLINTON, Issued Date:10/4/2011, Expired Date:10/3/2013 12:00:00 PM, Drilling unit acres:164.5, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2011-10-29 | |
Completion Report Received | 2012-09-19 | |
Construction Permit Expires | 2013-10-03 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-10-11 | 3135 | 3149 | 15 |
2012-10-11 | 3156 | 3160 | 5 |
3135 | 3149 | 15 | |
3156 | 3160 | 5 | |
3176 | 3188 | 13 | |
3135 | 3149 | 15 | |
2012-10-11 | 3176 | 3188 | 13 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2011-11-10 | H2O | 15 | 60000 Gal | 30000 | Universal Well Services Inc. | |
2011-11-10 | H2O | 15 | 1500 Bbl | 30000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | BABCOCK RONALD W | 0.00 | 0.00 | 30 |
2012 | BABCOCK RONALD W | 0.00 | 1190.00 | 366 |
2013 | BABCOCK RONALD W | 0.00 | 685.00 | 365 |
2014 | BABCOCK RONALD W | 0.00 | 562.00 | 365 |
2015 | BABCOCK RONALD W | 0.00 | 346.00 | 365 |
2016 | BABCOCK RONALD W | 0.00 | 269.00 | 365 |
2017 | BABCOCK RONALD W | 0.00 | 220.00 | 365 |
2018 | BABCOCK RONALD W | 0.00 | 218.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | BABCOCK RONALD W | Brine | 160 | 30 |
2012 | BABCOCK RONALD W | Brine | 220 | 366 |
2013 | BABCOCK RONALD W | Brine | 100 | 365 |
2014 | BABCOCK RONALD W | Brine | 30 | 365 |
2015 | BABCOCK RONALD W | Brine | 0 | 365 |
2016 | BABCOCK RONALD W | Brine | 59 | 365 |
2017 | BABCOCK RONALD W | Brine | 0 | 365 |
2018 | BABCOCK RONALD W | Brine | 53 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1771190560 | 2012-12-20 0:00 | PL | No Violations | |
-796211523 | 2011-10-25 0:00 | DD | No Violations | |
-887453129 | 2011-11-10 0:00 | CT | No Violations | |
0398012451 | 2011-11-28 | Production Wells | No Violations | Well drilled and pumping this inspection. |
0796211523 | 2011-10-25 | Drill / Deepen / Reopen | No Violations | Drilling @ 1350. |
0887453129 | 2011-11-10 | Completion Testing | No Violations | Well fracked this by Universal. |
1771190560 | 2012-12-20 | Preliminary Restoration | No Violations | On the day of my inspection I found that the well head was equipped with a pumping unit and connected to a tank battery that consisted of two 100 barrel stock tanks, one separator and an earthen dike. Proper identification was posted and there were no leaks or spills. The site at the well head was primarily sand and sandstone. There was only about 30% vegetation coverage and there were signs of channeling from rainwater run off. I spoke with Mr. Babcock who acknowledged the poor vegetative coverage. He will re-seed the area when reclaiming the drill site for permit 7206. This site does not pass restoration at this time. |
1920936584 | 2012-02-07 | Production Wells | No Violations | The well is equipped with a pumping unit. There are 2-100 barrel storage tanks, 1- |
398012451 | 2011-11-28 0:00 | PW | No Violations |
For data sources see[9]