If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-20980 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.36,"lon":-81.89,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: GENESIS RESOURCES LLC | |
Well Pad ID: | |
Farm/Lease Name: PDK CO-SHYLO UNIT | |
License Status: Producing | |
License Date: 1980-08-22 | |
Spud Date: 1980-09-02 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-10-07 | |
Well Total Depth: 2785.00 ft | |
Configuration: Vertical | |
Latitude: 41.360000 | |
Longitude: -81.890000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-08-22 | 1453 GREEN ENERGY INC GeoDate 8/22/80 |
Oil and Gas | 1980-08-22 | Issued Date 8/22/80 Expired Date Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1980-09-02 | |
Completed | 1980-10-07 | |
Reached Total Depth | 1980-10-07 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2685 | 2707 | 12 |
2685 | 2707 | 12 | |
2685 | 2707 | 12 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1400 Bbl | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | GREEN ENERGY INC | 24483.00 | 56.00 | 0 |
1985 | GREEN ENERGY INC | 4245.00 | 0.00 | 0 |
1986 | GREEN ENERGY INC | 2550.00 | 0.00 | 365 |
1987 | GREEN ENERGY INC | 1675.00 | 0.00 | 365 |
1988 | GREEN ENERGY INC | 2932.00 | 0.00 | 365 |
1989 | GREEN ENERGY INC | 1771.00 | 0.00 | 365 |
1990 | GREEN ENERGY INC | 2090.00 | 0.00 | 365 |
1991 | GREEN ENERGY INC | 4762.00 | 0.00 | 365 |
1993 | GREEN ENERGY INC | 4290.00 | 0.00 | 365 |
1994 | GREEN ENERGY INC | 3177.00 | 0.00 | 365 |
1995 | GREEN ENERGY INC | 2818.00 | 37.00 | 365 |
1996 | GREEN ENERGY INC | 2339.00 | 0.00 | 365 |
1997 | GREEN ENERGY INC | 1986.00 | 0.00 | 365 |
1998 | GREEN ENERGY INC | 2176.00 | 0.00 | 365 |
1999 | GREEN ENERGY INC | 1045.00 | 0.00 | 365 |
2000 | GREEN ENERGY INC | 1547.00 | 0.00 | 365 |
2001 | GREEN ENERGY INC | 1676.00 | 0.00 | 365 |
2002 | GREEN ENERGY INC | 70.00 | 0.00 | 365 |
2003 | GREEN ENERGY INC | 34.00 | 0.00 | 30 |
2004 | GREEN ENERGY INC | 0.00 | 0.00 | 0 |
2005 | GREEN ENERGY INC | 0.00 | 0.00 | 0 |
2006 | GREEN ENERGY INC | 0.00 | 0.00 | 0 |
2007 | GREEN ENERGY INC | 455.00 | 0.00 | 153 |
2008 | GREEN ENERGY INC | 2569.00 | 0.00 | 366 |
2009 | GREEN ENERGY INC | 2008.00 | 0.00 | 365 |
2010 | GREEN ENERGY INC | 1886.00 | 0.00 | 365 |
2011 | GREEN ENERGY INC | 1864.00 | 0.00 | 365 |
2012 | GREEN ENERGY INC | 1840.00 | 0.00 | 366 |
2013 | GREEN ENERGY INC | 1748.00 | 12.00 | 365 |
2014 | GREEN ENERGY INC | 1468.00 | 0.00 | 365 |
2015 | GREEN ENERGY INC | 1273.00 | 0.00 | 365 |
2016 | GREEN ENERGY INC | 1349.00 | 0.00 | 365 |
2017 | GREEN ENERGY INC | 1096.00 | 0.00 | 365 |
2018 | GREEN ENERGY INC | 975.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | GREEN ENERGY INC | Brine | 0 | 0 |
1985 | GREEN ENERGY INC | Brine | 0 | 0 |
1986 | GREEN ENERGY INC | Brine | 0 | 365 |
1987 | GREEN ENERGY INC | Brine | 0 | 365 |
1988 | GREEN ENERGY INC | Brine | 0 | 365 |
1989 | GREEN ENERGY INC | Brine | 0 | 365 |
1990 | GREEN ENERGY INC | Brine | 35 | 365 |
1991 | GREEN ENERGY INC | Brine | 0 | 365 |
1993 | GREEN ENERGY INC | Brine | 0 | 365 |
1994 | GREEN ENERGY INC | Brine | 0 | 365 |
1995 | GREEN ENERGY INC | Brine | 42 | 365 |
1996 | GREEN ENERGY INC | Brine | 0 | 365 |
1997 | GREEN ENERGY INC | Brine | 0 | 365 |
1998 | GREEN ENERGY INC | Brine | 0 | 365 |
1999 | GREEN ENERGY INC | Brine | 0 | 365 |
2000 | GREEN ENERGY INC | Brine | 0 | 365 |
2001 | GREEN ENERGY INC | Brine | 0 | 365 |
2002 | GREEN ENERGY INC | Brine | 0 | 365 |
2003 | GREEN ENERGY INC | Brine | 0 | 30 |
2004 | GREEN ENERGY INC | Brine | 0 | 0 |
2005 | GREEN ENERGY INC | Brine | 0 | 0 |
2006 | GREEN ENERGY INC | Brine | 0 | 0 |
2007 | GREEN ENERGY INC | Brine | 0 | 153 |
2008 | GREEN ENERGY INC | Brine | 0 | 366 |
2009 | GREEN ENERGY INC | Brine | 0 | 365 |
2010 | GREEN ENERGY INC | Brine | 0 | 365 |
2011 | GREEN ENERGY INC | Brine | 0 | 365 |
2012 | GREEN ENERGY INC | Brine | 0 | 366 |
2013 | GREEN ENERGY INC | Brine | 57 | 365 |
2014 | GREEN ENERGY INC | Brine | 0 | 365 |
2015 | GREEN ENERGY INC | Brine | 0 | 365 |
2016 | GREEN ENERGY INC | Brine | 0 | 365 |
2017 | GREEN ENERGY INC | Brine | 0 | 365 |
2018 | GREEN ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1104599014 | 2018-8-10 0:00: | UP | No Violations | 0.50 |
-1249737761 | 2013-9-19 0:00: | UP | No Violations | |
0157003344 | 2014-08-11 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well was completed in 10/07/1980. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and concoil production system and aboveground storage tank (AST) battery. The wellhead is located in the West Grove Village condo development. The battery is located adjacent to a decorative pond near the wellhead. The well and battery are accessed via a short, gravel-paved road which is accessed from Bagley Road, just west of the office strip. The battery is comprised of 1 steel 100-barrel production tank, and vertical separator. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-out is bull-plugged and locked. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery but no signage at the well. No problems requiring attention at the time of this inspection. I contacted Green Energy about the need for signage at the well and was advised it would be taken care of as soon as possible. |
0691018576 | 2015-04-30 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The wellhead is comprised of a concoil system and is located within a decorative gazebo structure. The access door to the gazebo is locked and secure. Fittings and connections are secure and free from signs of leakage or problems. The battery is remotely located along the commercial and light industrial portion of Bagley Road in a clearing in an otherwise undeveloped parcel comprised of meadow grass and brushy vegetation. The battery is comprised of one 100-barrel steel production tank and separator unit. Secondary containment is present and intact with a small amount of residual rainwater. Load-outs are plugged and secure. The tank and other elements are aged and showing some surface corrosion but the fittings and connections and secure, intact and not showing any signs of leakage or other problems with integrity. The area is flat-lying with surface drainage via infiltration. I inspected the surrounding areas and did not observe any signs of impact relating to the production operation. The access road to the battery is unpaved and worn, but passable and not showing significant drainage issues. |
0993554067 | 2013-03-13 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: A production wellhead and storage tank battery. The production wellhead is fitted with a mechanical plunger lift system and is located across a decorative pond from the tank battery. The wellhead is enclosed in a decorative gazebo structure, but does not have identification. The tank battery system includes 1 100-barrel storage tank, mechanical separator and associated appurtenances. The tank battery is enclosed in an 8-foot chainlink enclosure. The enclosure is locked and the secondary containment is adequate. I contacted Jim with Green Energy about the need for identification. He indicated that he would tend to the issue. |
1104599014 | 2018-08-10 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. Fittings and connections at the wellhead concoil were secure and free from leakage or problems. Secondary containment is present and intact. Load-outs were plugged and secure. I inspected the surrounding areas and did not observe any signs of impact relating to the production operation. I contacted the well owner about placing a ID sign at the remote wellhead. The owner indicated the sign would be placed ASAP. |
1249737761 | 2013-09-19 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead with concoil unit in a chain- link fence. The aboveground storage tank battery is comprised of 1 100-barrel steel production tank and separator in a chain- link fence. ID placards are present and emergency #s are current. No observed problems. |
1500655866 | 2017-07-21 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. Fittings and connections at the wellhead concoil were secure and free from leakage or problems. The wellhead enclosure was locked and secure. The battery is remotely located along the commercial and light industrial portion of Bagley Road in a clearing in an otherwise undeveloped parcel comprised of meadow grass and brushy vegetation. Secondary containment is present and intact. Load-outs were plugged and secure. I inspected the surrounding areas and did not observe any signs of impact relating to the production operation. The access road to the battery is unpaved and worn, but passable and not showing significant drainage issues. |
157003344 | 2014-8-11 0:00: | UP | No Violations | |
1960101941 | 2020-1-27 0:00: | PW | No Violations | |
691018576 | 2015-4-30 0:00: | UP | No Violations | 0.50 |
993554067 | 2013-3-13 0:00: | UP | No Violations |
For data sources see[9]