X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21151

Well Details

Well ID: 34-035-21151
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: PERGER UNIT
License Status: Producing
License Date: 1982-05-25
Spud Date: 1982-07-23
Spud Drilling Contractor: FITZGERALD DRLG
Final Drill Date: 1982-08-27
Well Total Depth: 2800.00 ft
Configuration: Vertical
Latitude: 41.360000
Longitude: -81.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-05-25 Issued Date 5/25/82 Expired Date 11/15/82 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 02800 Proposed Drill Depth 02800
Original Spud 1982-07-23
Completed 1982-08-27
Reached Total Depth 1982-08-27
CO 1982-09-15 1453 GREEN ENERGY INC GeoDate 5/25/82
Construction Permit Expires 1982-11-15
Completion Report Received 1983-11-16
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2713 2773 11
2713 2773 11
2713 2773 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 68000 Gal 30000 FRAC: 68MG H2O, 30M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GREEN ENERGY INC 11929.00 666.00 0
1985 GREEN ENERGY INC 8090.00 474.00 0
1986 GREEN ENERGY INC 4925.00 229.00 365
1987 GREEN ENERGY INC 3242.00 298.00 365
1988 GREEN ENERGY INC 2160.00 70.00 365
1989 GREEN ENERGY INC 2238.00 165.00 365
1990 GREEN ENERGY INC 3526.00 144.00 35
1991 GREEN ENERGY INC 1710.00 82.00 365
1992 GREEN ENERGY INC 2042.00 114.00 365
1993 GREEN ENERGY INC 1649.00 125.00 365
1994 GREEN ENERGY INC 1972.00 110.00 365
1995 GREEN ENERGY INC 4325.00 125.00 365
1996 GREEN ENERGY INC 2912.00 57.00 365
1997 GREEN ENERGY INC 3119.00 50.00 365
1998 GREEN ENERGY INC 1759.00 51.00 365
1999 GREEN ENERGY INC 1486.00 0.00 365
2000 GREEN ENERGY INC 1289.00 110.00 365
2001 GREEN ENERGY INC 1124.00 0.00 365
2002 GREEN ENERGY INC 1359.00 135.00 365
2003 GREEN ENERGY INC 1218.00 61.00 365
2004 GREEN ENERGY INC 1014.00 0.00 365
2005 GREEN ENERGY INC 1357.00 63.00 365
2006 GREEN ENERGY INC 893.00 0.00 365
2007 GREEN ENERGY INC 1740.00 54.00 365
2008 GREEN ENERGY INC 1805.00 56.00 366
2009 GREEN ENERGY INC 1684.00 65.00 365
2010 GREEN ENERGY INC 1684.00 73.00 365
2011 GREEN ENERGY INC 1705.00 59.00 365
2012 GREEN ENERGY INC 1452.00 53.00 366
2013 GREEN ENERGY INC 1215.00 52.00 365
2014 GREEN ENERGY INC 1300.00 44.00 365
2015 GREEN ENERGY INC 1405.00 52.00 365
2016 GREEN ENERGY INC 1513.00 47.00 365
2017 GREEN ENERGY INC 1322.00 45.00 365
2018 GREEN ENERGY INC 1397.00 40.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GREEN ENERGY INC Brine 0 0
1985 GREEN ENERGY INC Brine 80 0
1986 GREEN ENERGY INC Brine 40 365
1987 GREEN ENERGY INC Brine 77 365
1988 GREEN ENERGY INC Brine 20 365
1989 GREEN ENERGY INC Brine 40 365
1990 GREEN ENERGY INC Brine 0 35
1991 GREEN ENERGY INC Brine 35 365
1992 GREEN ENERGY INC Brine 27 365
1993 GREEN ENERGY INC Brine 0 365
1994 GREEN ENERGY INC Brine 40 365
1995 GREEN ENERGY INC Brine 18 365
1996 GREEN ENERGY INC Brine 0 365
1997 GREEN ENERGY INC Brine 0 365
1998 GREEN ENERGY INC Brine 0 365
1999 GREEN ENERGY INC Brine 0 365
2000 GREEN ENERGY INC Brine 15 365
2001 GREEN ENERGY INC Brine 0 365
2002 GREEN ENERGY INC Brine 0 365
2003 GREEN ENERGY INC Brine 0 365
2004 GREEN ENERGY INC Brine 0 365
2005 GREEN ENERGY INC Brine 0 365
2006 GREEN ENERGY INC Brine 0 365
2007 GREEN ENERGY INC Brine 40 365
2008 GREEN ENERGY INC Brine 0 366
2009 GREEN ENERGY INC Brine 0 365
2010 GREEN ENERGY INC Brine 0 365
2011 GREEN ENERGY INC Brine 0 365
2012 GREEN ENERGY INC Brine 20 366
2013 GREEN ENERGY INC Brine 0 365
2014 GREEN ENERGY INC Brine 0 365
2015 GREEN ENERGY INC Brine 0 365
2016 GREEN ENERGY INC Brine 0 365
2017 GREEN ENERGY INC Brine 0 365
2018 GREEN ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1174491887 2015-4-30 0:00: UP No Violations 1.00
-34269185 2014-10-20 0:00 UP No Violations
0034269185 2014-10-20 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a pump jack system in a chain-link enclosure. The well is producing and production reports are current. Fittings and valve-connections are intact and free from leaks or problems. There is some minor oil staining around the base of the wellhead. The tank battery is comprised of 1 100-barrel production tank and separator unit, not enclosed. The load-outs are bull-plugged. There is secondary containment. The interior portions of the battery are dry and well maintained. There is some minor oil staining at the load-outs but otherwise no signs of leaks, spills, or other problems.
0118322136 2018-08-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. Fittings and connections at the wellhead pumpjack were secure and free from signs of leakage or problems. I inspected the areas surrounding the wellhead and did not observe any signs of impact relating to the production operation. Fittings and connections at the battery were secure. Secondary containment was intact and dry. Load-outs were secure. I inspected areas surrounding the battery and did not observe any signs of impact relating to production activates.
0764622835 2017-07-21 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead is comprised of a pump jack system which is located in a meadow. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. I inspected the areas surrounding the wellhead and did not observe any signs of impact relating to the production operation. Fittings and connections at the battery were secure. Secondary containment was intact and dry. Load-outs were secure. I inspected areas surrounding the battery and did not observe any signs of impact relating to production activates.
1174491887 2015-04-30 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead is comprised of a pump jack system which is located in a fallow farm field on a larger farmstead. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. Surface drainage in the area of the wellhead appears to be mostly infiltration. I inspected the areas surrounding the wellhead and did not observe any signs of impact relating to the production operation (e.g. staining, stressed or dead vegetation). Access to the wellhead is from the private driveway of the farmstead and is mostly overgrown and very soft from ponded water. The battery is located close to West Road and is accessed separately via a short, unpaved road. The battery is comprised of 1 100-barrel steel production tank, one 50-barrel poly brine tank, and separator unit. Secondary containment is intact and dry. Load-outs are secure. The battery is shard with the #2-0954 unit. Areas surrounding the battery are wooded and flat-lying. I inspected areas surrounding the battery and did not observe any signs of impact relating to production activates.
118322136 2018-8-10 0:00: UP No Violations 0.50
2005105918 2014-08-11 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 08/27/1982. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and natural gas-fired pump jack system and aboveground storage tank (AST) battery. The wellhead is located in an unplowed farm field 600 feet northwest of the Peger farmhouse. There is remnants of an access road which is grassy and mostly overgrown. The battery is located approximately 900 feet southwest of the wellhead, and is accessed from a separate, short dedicated gravel road. The battery is 75 feet north of West Road. The battery is comprised of 1 steel 100-barrel production tank, 1 25-barrel poly brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-out is bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. The ID placard at the battery is not readable. I notified Green Energy about the ID placard deficiency.
764622835 2017-7-21 0:00: UP No Violations

For data sources see[9]

References