Well Details

Well ID: 34-035-21721
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DUCK CREEK ENERGY INC
Well Pad ID:
Farm/Lease Name: RIVER RECYCLING INDUSTRIES UNIT # 1
License Status: Producing
License Date: 2001-04-06
Spud Date: 2001-04-25
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2001-04-29
Well Total Depth: 2924.00 ft
Configuration: Vertical
Latitude: 41.440000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-04-06 1902 DUCK CREEK ENERGY INC Proposed Formation CLINTON Issued Date 4/6/01 Expired Date 4/6/02 6:00:00 AM
Original Spud 2001-04-25 RBDMS Rec
Completed 2001-04-29 RBDMS Rec
Reached Total Depth 2001-04-29 RBDMS Rec
Completion Report Received 2002-04-02 RBDMS Rec
Construction Permit Expires 2002-04-06 RBDMS Rec
Correction to Well 2003-04-11 UNIT SIZE INCREASED TO 23.68 ACRES.
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-06-11 2750 2796 23
2750 2796 23
2750 2796 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 60000 Gal 0 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 DUCK CREEK ENERGY INC 3054.00 0.00 92
2002 DUCK CREEK ENERGY INC 11202.00 0.00 365
2003 DUCK CREEK ENERGY INC 11545.00 123.00 365
2004 DUCK CREEK ENERGY INC 8781.00 112.00 365
2005 DUCK CREEK ENERGY INC 8701.00 82.00 365
2006 DUCK CREEK ENERGY INC 6570.00 0.00 365
2007 DUCK CREEK ENERGY INC 5888.00 0.00 365
2008 DUCK CREEK ENERGY INC 3278.00 64.00 365
2009 DUCK CREEK ENERGY INC 1037.00 0.00 365
2010 DUCK CREEK ENERGY INC 1587.00 0.00 365
2011 DUCK CREEK ENERGY INC 2594.00 0.00 365
2012 DUCK CREEK ENERGY INC 2270.00 0.00 366
2013 DUCK CREEK ENERGY INC 1612.00 122.00 365
2014 DUCK CREEK ENERGY INC 707.00 33.00 365
2015 DUCK CREEK ENERGY INC 704.00 0.00 365
2016 DUCK CREEK ENERGY INC 731.00 0.00 365
2017 DUCK CREEK ENERGY INC 813.00 46.00 365
2018 DUCK CREEK ENERGY INC 721.00 20.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 DUCK CREEK ENERGY INC Brine 195 92
2002 DUCK CREEK ENERGY INC Brine 880 365
2003 DUCK CREEK ENERGY INC Brine 1310 365
2004 DUCK CREEK ENERGY INC Brine 1295 365
2005 DUCK CREEK ENERGY INC Brine 1316 365
2006 DUCK CREEK ENERGY INC Brine 1189 365
2007 DUCK CREEK ENERGY INC Brine 1259 365
2008 DUCK CREEK ENERGY INC Brine 846 365
2009 DUCK CREEK ENERGY INC Brine 682 365
2010 DUCK CREEK ENERGY INC Brine 486 365
2011 DUCK CREEK ENERGY INC Brine 1182 365
2012 DUCK CREEK ENERGY INC Brine 1135 366
2013 DUCK CREEK ENERGY INC Brine 887 365
2014 DUCK CREEK ENERGY INC Brine 688 365
2015 DUCK CREEK ENERGY INC Brine 759 365
2016 DUCK CREEK ENERGY INC Brine 807 365
2017 DUCK CREEK ENERGY INC Brine 1180 365
2018 DUCK CREEK ENERGY INC Brine 856 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1642520235 2017-10-24 0:00 UP No Violations 0.50
0441969606 2016-11-16 UrbanProduction Wells No Violations I isnpected this well locattion as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with pump jack system and associated tank battery, both located within the confines of the River Recycling facility, at the edge of the asphalt-paved parking area. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The tank lid was closed and secure. Secondary containment was intact and free from signs of spills or leakage. Load lines were plugged and secure. I noted the following: there was several discarded pieces of production equipment (separator vessel, metal stair unit) which should be removed. I contacted Larry Gibler with Duck Creek Energy and advised about the need for removal of discarded equipment.
0910203873 2013-01-07 Preliminary Restoration No Violations The producing unit is comprised of a two-tank battery (1 210 and 1 140-barrel) with mechanical separator and a wellhead with pump jack. The wellhead and tank battery are both enclosed in one 6-foot chain link fence. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The is an apparent discarded portion of an old mechanical separator lying in the tank battery. There are also 2 55-gallon plastic chemical drums in the fence, outside of the secondary containment. I spoke with Adam Gibler about removing the drums and the old separator unit. He indicated that the items would be removed.
1642520235 2017-10-24 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located on a parcel otherwise utilized for industrial use. At the time of this inspection, I observed the following: a wellhead with pump jack system which was in operation. Fittings and connections at the well were secure and free from signs of leakage or problems. The associated tank battery is located next to the entry gate, with the well adjacent. The fittings and connections were secure. The discarded equipment that I had observed during a previous inspection had been removed. The load-lines were plugged, locked and secure. The secondary containment was intact and dry. Signage was present. I walked the areas surrounding the well and battery and found no signs of degradation or impact to the natural greenscape.
441969606 2016-11-16 0:00 UP No Violations 1.00
910203873 2013-1-7 0:00:0 PL No Violations

For data sources see[9]