Well ID: 34-035-21804 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.47,"lon":-81.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DUCK CREEK ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: ISG/DCE | |
License Status: Producing | |
License Date: 2004-02-11 | |
Spud Date: 2004-04-21 | |
Spud Drilling Contractor: CANTON WELL SERVICE | |
Final Drill Date: 2004-04-24 | |
Well Total Depth: 2890.00 ft | |
Configuration: Vertical | |
Latitude: 41.470000 | |
Longitude: -81.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2004-02-11 | Proposed Formations:CLINTON, Issued Date:2/11/2004, Expired Date:2/10/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-04-21 | RBDMS Rec |
Completed | 2004-04-24 | RBDMS Rec |
Reached Total Depth | 2004-04-24 | RBDMS Rec |
Completion Report Received | 2004-06-21 | RBDMS Rec |
Construction Permit Expires | 2005-02-10 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2004-08-19 | 2719 | 2762 | 25 |
2719 | 2762 | 25 | |
2719 | 2762 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 67000 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | DUCK CREEK ENERGY INC | 909.00 | 0.00 | 34 |
2005 | DUCK CREEK ENERGY INC | 8850.00 | 110.00 | 365 |
2006 | DUCK CREEK ENERGY INC | 4772.00 | 0.00 | 365 |
2007 | DUCK CREEK ENERGY INC | 2580.00 | 86.00 | 365 |
2008 | DUCK CREEK ENERGY INC | 3218.00 | 51.00 | 365 |
2009 | DUCK CREEK ENERGY INC | 2054.00 | 0.00 | 365 |
2010 | DUCK CREEK ENERGY INC | 1570.00 | 0.00 | 365 |
2011 | DUCK CREEK ENERGY INC | 1079.00 | 0.00 | 365 |
2012 | DUCK CREEK ENERGY INC | 909.00 | 99.00 | 366 |
2013 | DUCK CREEK ENERGY INC | 595.00 | 0.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 13.00 | 0.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 0.00 | 0.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 0.00 | 0.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 0.00 | 0.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2004 | DUCK CREEK ENERGY INC | Brine | 0 | 34 |
2005 | DUCK CREEK ENERGY INC | Brine | 240 | 365 |
2006 | DUCK CREEK ENERGY INC | Brine | 72 | 365 |
2007 | DUCK CREEK ENERGY INC | Brine | 145 | 365 |
2008 | DUCK CREEK ENERGY INC | Brine | 209 | 365 |
2009 | DUCK CREEK ENERGY INC | Brine | 212 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 70 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 116 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 125 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 300 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2026141354 | 2013-1-7 0:00:0 | UP | No Violations | |
1020511699 | 2014-05-30 | UrbanPreliminary Restoration | No Violations | I inspected this producing unit to evaluate conditions for preliminary restoration. The well was completed in 04/30/2010. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system. . There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located east and adjacent to the wellhead. The battery is comprised of 2 steel 140-barrel production tanks, 1 25-barrel poly brine tank, and a horizontal separator. The load-outs are bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area formerly occupied by drilling equipment, including former pits, has been restored and reclaimed. The area around the well is fill material and foundry slag. The area of the well is generally level with a slight topographic drop to the northwest. Surface draining appears to be to the northwest. There are no surface water courses evident near the site. I did not observe any signs of gully formation or washouts. Access to the unit is through the steel facility. There is no specific access roads or routes. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are heavy industrial. The requirements for Preliminary Restoration have passed. |
2026141354 | 2013-01-07 | UrbanProduction Wells | No Violations | The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator and a wellhead with pump jack. The wellhead and tank battery are not enclosed. The well is currently shut-in. The tank and well spacing is in accordance with 1509:9-9-05 . The secondary containment is adequate. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. |
For data sources see[9]