Well Details

Well ID: 34-035-21973
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: KALL UNIT
License Status: Producing
License Date: 2007-05-24
Spud Date: 2007-10-02
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2007-10-05
Well Total Depth: 3578.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-05-24 Proposed Formations:NEWBURG/CLINTON, Issued Date:5/24/2007, Expired Date:5/23/2008 6:00:00 AM, Drilling unit acres:22.33, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-10-05
Reached Total Depth 2007-10-05
Completion Report Received 2007-12-19
Construction Permit Expires 2008-05-23
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-03-07 3426 3453 19
3426 3453 19
3426 3453 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 78000 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 GONZOIL INC 8193.00 7469.00 275
2009 GONZOIL INC 17250.00 5868.00 365
2010 GONZOIL INC 12994.00 2759.00 365
2011 GONZOIL INC 14323.00 3147.00 365
2012 GONZOIL INC 13073.00 1891.00 366
2013 GONZOIL INC 6396.00 1254.00 365
2014 GONZOIL INC 5657.00 1326.00 365
2015 GONZOIL INC 5062.00 958.00 365
2016 GONZOIL INC 3213.00 497.00 365
2017 GONZOIL INC 3475.00 895.00 365
2018 GONZOIL INC 884.00 375.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 GONZOIL INC Brine 279 275
2009 GONZOIL INC Brine 507 365
2010 GONZOIL INC Brine 717 365
2011 GONZOIL INC Brine 1293 365
2012 GONZOIL INC Brine 1049 366
2013 GONZOIL INC Brine 605 365
2014 GONZOIL INC Brine 626 365
2015 GONZOIL INC Brine 702 365
2016 GONZOIL INC Brine 508 365
2017 GONZOIL INC Brine 564 365
2018 GONZOIL INC Brine 347 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1043016056 2017-5-24 0:00: UP No Violations 0.50
-1788873889 2019-5-1 0:00:0 UP No Violations
-2115198629 2015-9-3 0:00:0 UP No Violations 1.00
-679493091 2015-7-7 0:00:0 UP No Violations
-772560862 2012-12-3 0:00: PW No Violations 0.50
0109337829 2007-10-09 Drill / Deepen / Reopen No Violations pits fenced
0321691093 2015-04-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and tank battery are located in an open behind the house at the referenced address. The well is comprised of a pump jack system in a chain-link enclosure. The battery is comprised of 1 100-barrel steel production tank, 1 100-barrel poly brine tank, and mechanical separator. At the time of this inspection I observed some free-floating oil within the battery containment. Some mitigation efforts, as evidenced by the presence of several dozen absorbent pads and several booms, have been performed. I did not see any evidence of oil outside of the containment. Otherwise, fittings and connections at the wellhead and battery are secure. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact. I contacted Rick Reeve with Gonzoil regarding the oil in the containment. He indicated that the leak had been discovered after the snow melt. He said the remaining oil is being cleaned up and mitigated as it appears during rainfall events.
0679493091 2015-07-07 UrbanProduction Wells No Violations I inspected this producing unit as a follow up to an earlier inspection. At the previous inspection, I had observed a oil in the tank battery from an apparent release. Gonzoil Inc. indicated that efforts to mitigate and correct the problem were under way. At the time of this inspection, all of the free oil has been removed, but some oil-stained gravel ballast material remains. I contacted Gonzoil Inc. Doug Gonzalez indicated that they had been waiting for the rains to subside and allow clean-up to be completed. He indicated that this would be completed within two weeks. The unit otherwise is secure and free from signs of leakage or problems. Gates are locked and secure. Load-lines are plugged and locked. Hatch lids are sealed.
0772560862 2012-12-03 Production Wells No Violations My visit to the well site today was for an Urban Production well status check No violations were found. Well is in compliance.
1043016056 2017-05-24 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The wellhead is located in a small clearing in a wooded portion of a parcel on Akins Road utilized otherwise for agricultural purposes. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and battery were secure and free from leakage. The load-line valves were closed and plugged but missing locks. Tank lids were closed and secure. Individual enclosure gates were locked and secure. I inspected both the interior areas and exterior portions of the well and battery and surrounding areas and found no signs of impact or problem.
109337829 2007-10-9 0:00: DD No Violations
1341440751 2013-04-01 UrbanProduction Wells No Violations The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a pumpjack system and is currently producing. The pumpjack unit is enclosed in an 8-foot chain-link enclosure which is locked. The annular space is plumbed back to the production line. The tank battery consists of 2 100-barrel steel tanks, 1 50-barrel steel tank, and separator. The battery is enclosed in a chain-link enclosure. Safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present. The secondary containment is present and in good condition. No violations noted.
1431542806 2015-05-06 UrbanProduction Wells No Violations I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery and pumping unit are enclosed with a chain link privacy fence. Upon our inspection we found that the tank hatch on the two 140 barrel tank were equipped with the proper sealed hatch and lightning arrestors are installed. There is a charcoal filter installed with a vent. There were locks on the water and oil pick up line. All drums needs to be removed. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. There is oil staining on the ground at the wellhead. The electric box was not locked. ID signs are posted. DOGRM Inspector Steve Tompkins had inspected this location on 4/2/2015 and noticed an oil release. He had contacted Rick Reeves about the clean up. At this inspection there is still some clean up that needs to done around the inside of the dike area.
1470265146 2018-01-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. I found the wellhead pump jack and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area.
1533324304 2018-08-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. I found the wellhead pump jack and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. The well was in ownership transition and the new signage had been put up. The well was in active production.
1539991062 2013-11-15 UrbanProduction Wells No Violations No changes since the previous inspection. The unit is producing and no problems noted.
1636181239 2007-10-01 Preliminary Restoration No Violations location made
1648826505 2013-11-15 UrbanProduction Wells No Violations No changes since the previous inspection. The unit is producing and no problems noted.
2115198629 2015-09-03 UrbanProduction Wells No Violations I inspected this unit as a follow-up to an earlier inspection in which I had observed residual oil inside the tank battery. The oil had been related to a release that had occurred within the battery and was successfully mitigated but some residual material remained. At the time of this inspection, the owner has completed the mitigation and clean-up. Fittings and connections at the wellhead and battery are secure. Load-lines and electrical panels are locked. The interior dike is in good condition with a some ponded storm water which is clear and free of oils or sheen. The areas surrounding the well and battery are comprised of pasture land and gravel drive. A reconnaissance of these areas do not reveal any signs of impact associated with the producing unit. The dedicated unpaved access road is well drained. The gate at the head of the access is locked and secure. ID signage is posted at the road.
321691093 2015-4-2 0:00:0 UP No Violations 0.50

For data sources see[9]