{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.3,"lon":-81.69,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: <County> | |
| Municipality: | |
| Operator Name: MOORE RESOURCES LLC | |
| Well Pad ID: | |
| Farm/Lease Name: ROWE R UNIT | |
| License Status: Producing | |
| License Date: 2008-03-06 | |
| Spud Date: 2008-05-01 | |
| Spud Drilling Contractor: POULSON DRILLING | |
| Final Drill Date: 2008-05-08 | |
| Well Total Depth: 3612.00 ft | |
| Configuration: Vertical | |
| Latitude: 41.300000 | |
| Longitude: -81.690000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2008-03-06 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/6/2008, Expired Date:3/6/2009 6:00:00 AM, Drilling unit acres:22.0234, Proposed Well Type:OG, Proposed Well Class:POOL |
| Reached Total Depth | 2008-05-08 | |
| Completion Report Received | 2008-10-02 | |
| End of Confidential Data | 2008-11-08 | |
| Construction Permit Expires | 2009-03-06 | |
| Change of Owner | 2017-05-22 | Operator changed from 1249, CUTTER OIL CO to 7988, MOORE RESOURCES LLC |
| Record Last Modified | 2017-05-22 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2008-11-20 | 3416 | 3470 | 37 |
| 3416 | 3470 | 37 | |
| 3416 | 3470 | 37 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| H2O | 7 | 87830 Gal | 50000 | 185M SCF NITROGEN ASSIST |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | CUTTER OIL COMPANY | 2762.00 | 1982.00 | 199 |
| 2009 | CUTTER OIL COMPANY | 5535.00 | 3052.00 | 365 |
| 2010 | CUTTER OIL COMPANY | 5899.00 | 1864.00 | 365 |
| 2011 | CUTTER OIL COMPANY | 5391.00 | 1210.00 | 365 |
| 2012 | CUTTER OIL COMPANY | 4317.00 | 660.00 | 366 |
| 2013 | CUTTER OIL COMPANY | 3077.00 | 578.00 | 365 |
| 2014 | CUTTER OIL COMPANY | 2370.00 | 410.00 | 365 |
| 2015 | CUTTER OIL COMPANY | 1098.00 | 192.00 | 365 |
| 2016 | CUTTER OIL COMPANY | 454.00 | 106.00 | 365 |
| 2017 | MOORE RESOURCES LLC | 51.00 | 0.00 | 365 |
| 2018 | MOORE RESOURCES LLC | 0.00 | 0.00 | 0 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2008 | CUTTER OIL COMPANY | Brine | 2866 | 199 |
| 2009 | CUTTER OIL COMPANY | Brine | 999 | 365 |
| 2010 | CUTTER OIL COMPANY | Brine | 1465 | 365 |
| 2011 | CUTTER OIL COMPANY | Brine | 1699 | 365 |
| 2012 | CUTTER OIL COMPANY | Brine | 1057 | 366 |
| 2013 | CUTTER OIL COMPANY | Brine | 852 | 365 |
| 2014 | CUTTER OIL COMPANY | Brine | 746 | 365 |
| 2015 | CUTTER OIL COMPANY | Brine | 592 | 365 |
| 2016 | CUTTER OIL COMPANY | Brine | 596 | 365 |
| 2017 | CUTTER OIL COMPANY | Brine | 0 | 120 |
| 2018 | MOORE RESOURCES LLC | Brine | 0 | 0 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1633151417 | 2008-5-8 0:00:0 | DD | No Violations | |
| -1639488171 | 2008-5-7 0:00:0 | DD | No Violations | |
| -1959980749 | 2018-1-3 0:00:0 | UP | No Violations | 0.50 |
| -2015296440 | 2008-5-13 0:00: | DD | No Violations | |
| -2132468622 | 2015-4-2 0:00:0 | UP | No Violations | 0.50 |
| -243893751 | 2019-5-1 0:00:0 | UP | No Violations | |
| -276872061 | 2016-4-4 0:00:0 | UP | No Violations | 1.00 |
| -364243032 | 2013-11-15 0:00 | UP | No Violations | |
| 0164326388 | 2008-05-02 | Drill / Deepen / Reopen | No Violations | surface |
| 0276872061 | 2016-04-04 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, the owner had been cited for the following: tanks lacking proper sealing lids, and load-line valves and electrical boxes were unsecure. At the time of this inspection, the tank lids were upgraded and the load-lines and electrical boxes were secure with locks. In addition, the ID signage has been upgraded to include missing information. The paraffin staining previously noted was cleaned up. No further activity is needed regarding the referenced compliance notice. |
| 0364243032 | 2013-11-15 | UrbanProduction Wells | No Violations | Unit is comprised of a pump jack and aboveground storage tank (AST) battery. The wellhead and battery are enclosed in separate board-on-board fences and are locked. The battery consists of 2 100-barrel production tanks, 1 50-barrel brine, and separator unit. ID placards, secondary containment and spacing are in compliance. The unit is producing and no problems observed |
| 0927506129 | 2018-08-03 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. I found the wellhead pump jack and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. The well was in ownership transition and the new signage had been put up. The well was in active production. |
| 1160242665 | 2017-05-24 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The wellhead is located in a small clearing in a residential parcel on Akins Road. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and battery were secure and free from leakage. The load-line valves were closed and plugged but missing locks. Tank lids were closed and secure. Individual enclosure gates were locked and secure. I inspected both the interior areas and exterior portions of the well and battery and surrounding areas and found no signs of impact or problem. |
| 1218645203 | 2008-06-04 | Drill / Deepen / Reopen | No Violations | on site because landowner stated that company is closer than 300 to property line ,on site company has surveyor on site to measure point to well (329) per Gasbarre surveyor. Called Supervisor Jay Cheslock to give info about measurement he said he will call landowner (Mr.Peskura) to advise him
of measurment. CASE CLOSED |
| 1313533557 | 2011-08-08 | UrbanPreliminary Restoration | No Violations | Urban Preliminary Restoration due. Restoration Passed |
| 1354552901 | 2012-12-03 | UrbanPreliminary Restoration | No Violations | My visit to the well today was to perform a Preliminary Restoration Inspection at the well site. The wellhead is neat and clean with no debris or oil leakage detected. The pump on this well was reworked on 11/12/2012. The wellhead is enclosed inside board on board fencing and is secured with locks. The tank battery consists of two 100 BBL storage tanks and caps and lids are secure. There is one 35 BBL Brine tank. The tanks have a vent system installed, to include a charcoal filter system. There is one vertical and one horizontal separator installed. There is a meter run installed. Dike is within standards for containment area. The access road consists of crushed limestone packed to a depth of six inches. |
| 1431533457 | 2015-05-06 | UrbanProduction Wells | Violations Noted | I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery is enclosed with a board on board fence. Upon our inspection we found that the tank hatches on the two 100 barrel tanks are not equipped with the proper sealed hatches and no lightning arrestors. There were no locks on the water or oil pick up lines. All unused pumps and drums needs to be removed. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. There is a compressor inside the fenced in area. There is paraffin on the ground at the wellhead. This needs to be removed and contaminated soil removed and disposed of. All unused chemical pumps and drums needs to be removed. The electric boxes were not locked. ID signs are posted but are not in compliance with 1501:9-9-05--( E ).
1) Install proper sealed hatches 2) Install locks on oil and water valves at tanks or load lines and electric box. 3) Additional identification information is needs to bring the sign into compliance as required by 1501:9-9-05 ( E ) |
| 1633151417 | 2008-05-08 | Drill / Deepen / Reopen | No Violations | logging no priblems NO gas no fluid flow |
| 1639488171 | 2008-05-07 | Drill / Deepen / Reopen | No Violations | drilling 3387 no gas or fluid flow |
| 164326388 | 2008-5-2 0:00:0 | DD | No Violations | |
| 1959980749 | 2018-01-03 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located at the back of a residential parcel. I found the wellhead and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area. |
| 1971726243 | 2015-05-06 | UrbanProduction Wells | Violations Noted | FOLLOW UP TO NOV # 1431533457 I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery is enclosed with a board on board fence. Upon our inspection we found that the tank hatches on the two 100 barrel tanks are not equipped with the proper sealed hatches and no lightning arrestors. There were no locks on the water or oil pick up lines. All unused pumps and drums needs to be removed. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. There is a compressor inside the fenced in area. There is paraffin on the ground at the wellhead. This needs to be removed and contaminated soil removed and disposed of. All unused chemical pumps and drums needs to be removed. The electric boxes were not locked. ID signs are posted but are not in compliance with 1501:9-9-05--( E ).
1) Install proper sealed hatches 2) Install locks on oil and water valves at tanks or load lines and electric box. 3) Additional identification information is needs to bring the sign into compliance as required by 1501:9-9-05 ( E ) |
| 2015296440 | 2008-05-13 | Drill / Deepen / Reopen | No Violations | solidfying pits |
| 2132468622 | 2015-04-02 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The well and tank battery are located in an open, grassy area behind the house at the referenced address. The well is comprised of a pump jack system in a board-on-board enclosure. The battery is comprised of 2 100-barrel steel production tanks, 1 50-barrel poly brine tank, and mechanical separator. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact. |
| 927506129 | 2018-8-3 0:00:0 | UP | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 1431533457 | US-OH-112611 | 2015-07-02 | LOCKS | |
| 1431533457 | US-OH-112612 | 2015-07-02 | TANKS (a-i) | |
| 1971726243 | US-OH-119912 | 2016-09-26 | LOCKS | |
| 1971726243 | US-OH-119913 | 2016-09-26 | TANKS (a-i) |