34-035-22027

Well Details

Well ID: 34-035-22027
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: MOORE RESOURCES LLC
Well Pad ID:
Farm/Lease Name: ROWE R UNIT
License Status: Producing
License Date: 2008-03-06
Spud Date: 2008-05-01
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-05-08
Well Total Depth: 3612.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-03-06 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/6/2008, Expired Date:3/6/2009 6:00:00 AM, Drilling unit acres:22.0234, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-05-08
Completion Report Received 2008-10-02
End of Confidential Data 2008-11-08
Construction Permit Expires 2009-03-06
Change of Owner 2017-05-22 Operator changed from 1249, CUTTER OIL CO to 7988, MOORE RESOURCES LLC
Record Last Modified 2017-05-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-11-20 3416 3470 37
3416 3470 37
3416 3470 37

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 7 87830 Gal 50000 185M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY 2762.00 1982.00 199
2009 CUTTER OIL COMPANY 5535.00 3052.00 365
2010 CUTTER OIL COMPANY 5899.00 1864.00 365
2011 CUTTER OIL COMPANY 5391.00 1210.00 365
2012 CUTTER OIL COMPANY 4317.00 660.00 366
2013 CUTTER OIL COMPANY 3077.00 578.00 365
2014 CUTTER OIL COMPANY 2370.00 410.00 365
2015 CUTTER OIL COMPANY 1098.00 192.00 365
2016 CUTTER OIL COMPANY 454.00 106.00 365
2017 MOORE RESOURCES LLC 51.00 0.00 365
2018 MOORE RESOURCES LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY Brine 2866 199
2009 CUTTER OIL COMPANY Brine 999 365
2010 CUTTER OIL COMPANY Brine 1465 365
2011 CUTTER OIL COMPANY Brine 1699 365
2012 CUTTER OIL COMPANY Brine 1057 366
2013 CUTTER OIL COMPANY Brine 852 365
2014 CUTTER OIL COMPANY Brine 746 365
2015 CUTTER OIL COMPANY Brine 592 365
2016 CUTTER OIL COMPANY Brine 596 365
2017 CUTTER OIL COMPANY Brine 0 120
2018 MOORE RESOURCES LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1633151417 2008-5-8 0:00:0 DD No Violations
-1639488171 2008-5-7 0:00:0 DD No Violations
-1959980749 2018-1-3 0:00:0 UP No Violations 0.50
-2015296440 2008-5-13 0:00: DD No Violations
-2132468622 2015-4-2 0:00:0 UP No Violations 0.50
-243893751 2019-5-1 0:00:0 UP No Violations
-276872061 2016-4-4 0:00:0 UP No Violations 1.00
-364243032 2013-11-15 0:00 UP No Violations
0164326388 2008-05-02 Drill / Deepen / Reopen No Violations surface
0276872061 2016-04-04 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, the owner had been cited for the following: tanks lacking proper sealing lids, and load-line valves and electrical boxes were unsecure. At the time of this inspection, the tank lids were upgraded and the load-lines and electrical boxes were secure with locks. In addition, the ID signage has been upgraded to include missing information. The paraffin staining previously noted was cleaned up. No further activity is needed regarding the referenced compliance notice.
0364243032 2013-11-15 UrbanProduction Wells No Violations Unit is comprised of a pump jack and aboveground storage tank (AST) battery. The wellhead and battery are enclosed in separate board-on-board fences and are locked. The battery consists of 2 100-barrel production tanks, 1 50-barrel brine, and separator unit. ID placards, secondary containment and spacing are in compliance. The unit is producing and no problems observed
0927506129 2018-08-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. I found the wellhead pump jack and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. The well was in ownership transition and the new signage had been put up. The well was in active production.
1160242665 2017-05-24 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The wellhead is located in a small clearing in a residential parcel on Akins Road. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and battery were secure and free from leakage. The load-line valves were closed and plugged but missing locks. Tank lids were closed and secure. Individual enclosure gates were locked and secure. I inspected both the interior areas and exterior portions of the well and battery and surrounding areas and found no signs of impact or problem.
1218645203 2008-06-04 Drill / Deepen / Reopen No Violations on site because landowner stated that company is closer than 300 to property line ,on site company has surveyor on site to measure point to well (329) per Gasbarre surveyor. Called Supervisor Jay Cheslock to give info about measurement he said he will call landowner (Mr.Peskura) to advise him

of measurment.

CASE CLOSED

1313533557 2011-08-08 UrbanPreliminary Restoration No Violations Urban Preliminary Restoration due. Restoration Passed
1354552901 2012-12-03 UrbanPreliminary Restoration No Violations My visit to the well today was to perform a Preliminary Restoration Inspection at the well site. The wellhead is neat and clean with no debris or oil leakage detected. The pump on this well was reworked on 11/12/2012. The wellhead is enclosed inside board on board fencing and is secured with locks. The tank battery consists of two 100 BBL storage tanks and caps and lids are secure. There is one 35 BBL Brine tank. The tanks have a vent system installed, to include a charcoal filter system. There is one vertical and one horizontal separator installed. There is a meter run installed. Dike is within standards for containment area. The access road consists of crushed limestone packed to a depth of six inches.
1431533457 2015-05-06 UrbanProduction Wells Violations Noted I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery is enclosed with a board on board fence. Upon our inspection we found that the tank hatches on the two 100 barrel tanks are not equipped with the proper sealed hatches and no lightning arrestors. There were no locks on the water or oil pick up lines. All unused pumps and drums needs to be removed. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. There is a compressor inside the fenced in area. There is paraffin on the ground at the wellhead. This needs to be removed and contaminated soil removed and disposed of. All unused chemical pumps and drums needs to be removed. The electric boxes were not locked. ID signs are posted but are not in compliance with 1501:9-9-05--( E ).
 1) Install proper sealed hatches
 2) Install locks on oil and water valves at tanks or load lines and electric box. 
 3) Additional identification information is needs to bring the sign into compliance as required by 1501:9-9-05 ( E )
1633151417 2008-05-08 Drill / Deepen / Reopen No Violations logging no priblems NO gas no fluid flow
1639488171 2008-05-07 Drill / Deepen / Reopen No Violations drilling 3387 no gas or fluid flow
164326388 2008-5-2 0:00:0 DD No Violations
1959980749 2018-01-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located at the back of a residential parcel. I found the wellhead and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area.
1971726243 2015-05-06 UrbanProduction Wells Violations Noted FOLLOW UP TO NOV # 1431533457 I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery is enclosed with a board on board fence. Upon our inspection we found that the tank hatches on the two 100 barrel tanks are not equipped with the proper sealed hatches and no lightning arrestors. There were no locks on the water or oil pick up lines. All unused pumps and drums needs to be removed. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. There is a compressor inside the fenced in area. There is paraffin on the ground at the wellhead. This needs to be removed and contaminated soil removed and disposed of. All unused chemical pumps and drums needs to be removed. The electric boxes were not locked. ID signs are posted but are not in compliance with 1501:9-9-05--( E ).
 1) Install proper sealed hatches
 2) Install locks on oil and water valves at tanks or load lines and electric box. 
 3) Additional identification information is needs to bring the sign into compliance as required by 1501:9-9-05 ( E )
2015296440 2008-05-13 Drill / Deepen / Reopen No Violations solidfying pits
2132468622 2015-04-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and tank battery are located in an open, grassy area behind the house at the referenced address. The well is comprised of a pump jack system in a board-on-board enclosure. The battery is comprised of 2 100-barrel steel production tanks, 1 50-barrel poly brine tank, and mechanical separator. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact.
927506129 2018-8-3 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1431533457 US-OH-112611 2015-07-02 LOCKS
1431533457 US-OH-112612 2015-07-02 TANKS (a-i)
1971726243 US-OH-119912 2016-09-26 LOCKS
1971726243 US-OH-119913 2016-09-26 TANKS (a-i)

For data sources see[9]

References