X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-045-20735

Well Details

Well ID: 34-045-20735
Loading map...
Country: United States
State: Ohio
County: Fairfield
Municipality: Richland Township
Operator Name: KNOX ENERGY INC.
Well Pad ID:
Farm/Lease Name: FEATHEROLF RALPH & HENRIETTA
License Status: Final Restoration
License Date: 2005-09-26
Spud Date: 1981-11-13
Spud Drilling Contractor:
Final Drill Date: 1981-11-17
Well Total Depth: 2592.00 ft
Configuration: Vertical
Latitude: 39.780000
Longitude: -82.460000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-08-31 2118 MERCURY OIL & GAS GeoDate 8/31/81
Original Spud 1981-11-13
Completed 1981-11-17
Reached Total Depth 1981-11-17
CO 1991-09-26 795 B & B OIL/IRVIN & BURNS GeoDate 8/31/81
Change of Owner 1997-07-24 Operator changed from 795, B & B OIL/IRVIN & BURNS to 698, WRIGHT LARRY H INC (Well actually transferred on 4-16-94 from B D & W to Rainbow then a Form 7 was filed to trans well from Wright to Oil Enterprise that was processed on 7-24-97)
Change of Owner 2000-03-09 Operator changed from 4074, OIL ENTERPRISES to 4801, BANCEQUITY PETROLEUM CORP
Change of Owner 2005-01-11 Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 6295, KNOX ENERGY INC.
APP 2005-09-26 Proposed Formations:CLINTON, Issued Date:9/26/2005, Expired Date:9/26/2006 6:00:00 AM, Drilling unit acres:65.3, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2006-02-08
Construction Permit Expires 2006-09-26
Record Last Modified 2013-03-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2373 2376 1
2373 2376 1
2373 2376 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 SAND.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUESTA PETROLEUM CO 0.00 425.00 0
1985 QUESTA PETROLEUM CO 0.00 159.00 0
1986 QUESTA PETROLEUM CO 0.00 142.00 365
1987 QUESTA PETROLEUM CO 0.00 41.00 365
1997 OIL ENTERPRISES 0.00 40.00 365
1998 OIL ENTERPRISES 0.00 25.00 365
1999 OIL ENTERPRISES 0.00 0.00 0
2005 KNOX ENERGY INC. 0.00 0.00 0
2006 KNOX ENERGY INC. 0.00 0.00 40

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUESTA PETROLEUM CO Brine 0 0
1985 QUESTA PETROLEUM CO Brine 0 0
1986 QUESTA PETROLEUM CO Brine 0 365
1987 QUESTA PETROLEUM CO Brine 0 365
1997 OIL ENTERPRISES Brine 100 365
1998 OIL ENTERPRISES Brine 60 365
1999 OIL ENTERPRISES Brine 0 0
2005 KNOX ENERGY INC. Brine 0 0
2006 KNOX ENERGY INC. Brine 0 40

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1990261047 2012-1-2 0:00:0 FR No Violations
-2068465855 2005-7-7 0:00:0 PW No Violations
1095689313 2004-09-20 Production Wells Violations Noted Inspection revealed the well is equipped with surface equipment but the pumping unit has no motor on it. The tank battery has two (2) 100 Bbl. Tanks a knockout tank and a separator that is over grown and not accessible. The well is incapable of production.
1105540281 2005-01-11 Production Wells No Violations Follow-up revealed no change in the wells status.
1118751091 2005-06-14 Production Wells No Violations Follow-up revealed the new well owner has posted the proper identification at the tank battery but the well is still incapable production. This was after a phone call made by this inspector and a request made in writing from Mark Jordan with Knox Energy, Inc. dated 04/11/05 stating that the well would be plugged or producing with in sixty (60) days. I spoke with Mr. Conrad and he advised me that a crew had tried to pump the well on Thursday or Friday of last week but he did not know if it had worked because he was gone. At 10:20 A.M. I called Mark Jordan and he advised me that the well has a broken rod and they are planning to bring a rig in as soon as possible. He then advise me he would call Bill and then call me back with a date the rig would be there. At 3:34 P.M. Mr. Jordan called me back and advised a service rig would be on the well by the end of the week. At 8:11 P.M. I called and advised Mrs. Conrad that I was advised that a service rig would be on location by the end of the week.
1119028090 2005-06-17 Production Wells No Violations Follow-up revealed service rig over the well pulling rods. I meet with Mr. & Mrs. Conrad and advised them of my findings. I advised them that I would keep an eye on the well and would keep in contact with them and Knox Energy to make sure the well is producing or I will request it plugged, and at that time I will close the case file.
1120053093 2005-06-29 Production Wells No Violations Follow-up revealed no motor on the pumping unit.
1960160109 2004-10-21 Production Wells No Violations Follow-up revealed no change in wells status. Inspector has had no communication from well owner and have not received a plugging permit. Inspector to advise supervisor Fry on 10/22/04 and request permission to file for a Chiefs Order.
1990261047 2012-01-02 Final Restoration No Violations Site inspection for FR.
2068465855 2005-07-07 Production Wells No Violations Follow-up revealed pumping unit had no motor on.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1095689313 US-OH-102266 2004-09-20 Well shall be plugged

For data sources see[9]