If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-21813 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.94,"lon":-81.55,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Valley Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: DYER CARL & PATRICIA | |
License Status: Final Restoration | |
License Date: 2016-06-23 | |
Spud Date: 1974-08-27 | |
Spud Drilling Contractor: | |
Final Drill Date: 1974-09-06 | |
Well Total Depth: 5325.00 ft | |
Configuration: Vertical | |
Latitude: 39.940000 | |
Longitude: -81.550000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1974-07-18 | 182 BELDEN & BLAKE CO GeoDate 7/18/74 |
Original Spud | 1974-08-27 | |
Completed | 1974-09-06 | |
Reached Total Depth | 1974-09-06 | |
Change of Owner | 2002-08-07 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC |
Change of Owner | 2014-02-18 | Operator changed from 1966, PETROX, INC to 7578, ENERVEST OPERATING L |
APP | 2016-06-23 | Proposed Formations:CLINTON SAND, Issued Date:6/23/2016, Expired Date:6/23/2018 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2016-08-08 | |
Record Last Modified | 2017-02-10 | |
Construction Permit Expires | 2018-06-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5191 | 5210 | 2 |
5191 | 5210 | 2 | |
5191 | 5210 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 89000 Gal | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENTERPRISE ENERGY CORP | 0.00 | 411.00 | 0 |
1985 | OXFORD OIL | 0.00 | 408.00 | 365 |
1986 | OXFORD OIL | 0.00 | 275.00 | 365 |
1987 | BELDEN & BLAKE CORPORATION | 0.00 | 439.00 | 365 |
1988 | OXFORD OIL | 0.00 | 0.00 | 365 |
1990 | BELDEN & BLAKE CORPORATION | 546.00 | 339.00 | 175 |
1991 | BELDEN & BLAKE CORPORATION | 690.00 | 237.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 598.00 | 288.00 | 311 |
1993 | BELDEN & BLAKE CORPORATION | 275.00 | 103.00 | 209 |
1994 | BELDEN & BLAKE CORPORATION | 376.00 | 100.00 | 228 |
1995 | BELDEN & BLAKE CORPORATION | 515.00 | 212.00 | 327 |
1996 | BELDEN & BLAKE CORPORATION | 180.00 | 483.00 | 329 |
1997 | BELDEN & BLAKE CORPORATION | 13.00 | 242.00 | 358 |
1998 | BELDEN & BLAKE CORPORATION | 394.00 | 100.00 | 293 |
1999 | BELDEN & BLAKE CORPORATION | 454.00 | 98.00 | 183 |
2000 | BELDEN & BLAKE CORPORATION | 1.00 | 0.00 | 366 |
2001 | BELDEN & BLAKE CORPORATION | 96.00 | 0.00 | 201 |
2002 | PETROX, INC | 428.00 | 226.00 | 56 |
2003 | PETROX, INC | 660.00 | 165.00 | 365 |
2004 | PETROX, INC | 733.00 | 0.00 | 365 |
2005 | PETROX, INC | 674.00 | 0.00 | 365 |
2006 | PETROX, INC | 598.00 | 187.00 | 365 |
2007 | PETROX, INC | 367.00 | 189.00 | 365 |
2008 | PETROX, INC | 551.00 | 61.00 | 365 |
2009 | PETROX, INC | 598.00 | 68.00 | 365 |
2010 | PETROX, INC | 459.00 | 0.00 | 365 |
2011 | PETROX, INC | 348.00 | 136.00 | 365 |
2012 | PETROX, INC | 308.00 | 0.00 | 366 |
2013 | PETROX, INC | 243.00 | 0.00 | 365 |
2014 | PETROX, INC | 0.00 | 0.00 | 0 |
2015 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2016 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 218 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ENTERPRISE ENERGY CORP | Brine | 180 | 0 |
1985 | OXFORD OIL | Brine | 0 | 365 |
1986 | OXFORD OIL | Brine | 0 | 365 |
1987 | BELDEN & BLAKE CORPORATION | Brine | 5 | 365 |
1988 | OXFORD OIL | Brine | 0 | 365 |
1990 | BELDEN & BLAKE CORPORATION | Brine | 62 | 175 |
1991 | BELDEN & BLAKE CORPORATION | Brine | 38 | 365 |
1992 | BELDEN & BLAKE CORPORATION | Brine | 23 | 311 |
1993 | BELDEN & BLAKE CORPORATION | Brine | 7 | 209 |
1994 | BELDEN & BLAKE CORPORATION | Brine | 2 | 228 |
1995 | BELDEN & BLAKE CORPORATION | Brine | 11 | 327 |
1996 | BELDEN & BLAKE CORPORATION | Brine | 129 | 329 |
1997 | BELDEN & BLAKE CORPORATION | Brine | 49 | 358 |
1998 | BELDEN & BLAKE CORPORATION | Brine | 14 | 293 |
1999 | BELDEN & BLAKE CORPORATION | Brine | 10 | 183 |
2000 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
2001 | BELDEN & BLAKE CORPORATION | Brine | 14 | 201 |
2002 | BELDEN & BLAKE CORPORATION | Brine | 42 | 208 |
2003 | PETROX, INC | Brine | 2 | 365 |
2004 | PETROX, INC | Brine | 47 | 365 |
2005 | PETROX, INC | Brine | 14 | 365 |
2006 | PETROX, INC | Brine | 3 | 365 |
2007 | PETROX, INC | Brine | 365 | |
2008 | PETROX, INC | Brine | 10 | 365 |
2009 | PETROX, INC | Brine | 9 | 365 |
2010 | PETROX, INC | Brine | 0 | 365 |
2011 | PETROX, INC | Brine | 78 | 365 |
2012 | PETROX, INC | Brine | 57 | 366 |
2013 | PETROX, INC | Brine | 0 | 365 |
2014 | PETROX, INC | Brine | 0 | 0 |
2015 | ENERVEST OPERATING LLC | Brine | 0 | 0 |
2016 | ENERVEST OPERATING LLC | Brine | 249 | 218 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1181662701 | 2016-8-5 0:00:0 | PB | No Violations | 5.50 |
-1478729756 | 2016-4-6 0:00:0 | PW | No Violations | 1.00 |
-1550787290 | 2016-5-12 0:00: | PW | No Violations | 1.00 |
-172178417 | 2005-3-8 0:00:0 | PW | No Violations | |
-1990866090 | 2004-1-8 0:00:0 | PW | No Violations | |
-208973371 | 2016-5-27 0:00: | PW | No Violations | 1.00 |
-255930715 | 2003-7-29 0:00: | PW | No Violations | |
-311878004 | 2016-8-3 0:00:0 | PB | No Violations | 9.00 |
-66673115 | 2015-12-2 0:00: | PW | No Violations | 1.50 |
-70643313 | 2016-7-21 0:00: | PW | No Violations | 1.50 |
0024369050 | 2016-08-04 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed the valve on the 8.625 inch wellhead open revealing minimal pressure. Chipco tripped in and tagged the cement plug at 577 feet. Appalachian Well Surveys arrived and perforated the 5.5 inch casing with 10 shots from 510 feet to 500 feet. Chipco established circulation, performed bottoms up and pumped a 160 sack 510 foot Class A surface plug from 510 feet to surface. |
0066673115 | 2015-12-02 | Production Wells | No Violations | On the day of my inspection following up on NOV- |
0070643313 | 2016-07-21 | Production Wells | No Violations | On the day of my inspection following up on Compliance Notice-670412454 & Complaint ID #5104, I witnessed there was no change in the status of the well since the last inspection on 6/27/16. I requested an update from Enervest as to when plugging will take place. Enervest Superintendent Tim McConaha replied stating he will be moving to the site after plugging two wells in Muskingum County. |
0143755070 | 2006-09-20 | Production Wells | No Violations | PRODUCING WELL |
0172178417 | 2005-03-08 | Production Wells | No Violations | STATUS CHECK |
0189468234 | 2016-12-05 | Final Restoration | No Violations | On the day of my inspection I witnessed that the site passed final restoration according to ORC 1509.072B. |
0208973371 | 2016-05-27 | Production Wells | No Violations | On the day of my inspection following up on NOV-670412454 & Complaint ID #5104, I witnessed there was no change in the status of the well since the last inspection. I placed call to Enervest Superintendent Tim McConaha that tests have not been good since the packer was installed and they are looking at plugging the well. |
0255930715 | 2003-07-29 | Production Wells | No Violations | STATUS CHECK |
0311878004 | 2016-08-03 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed Chipco LLC unable to gain telegraph at 2500 feet and began ripping 5.5 inch casing at 2000 feet. Chipco was unable to rip casing and gain telegraph. Appalachian Well Surveys (AWS) was called out to perform a free point on 5.5 inch casing. Chipco pulled 100,000 on the 5.5 inch casing and did not gain any stretch. Chipco unsuccessfully tried to pump down the annulus of the 5.5 casing. AWS was unable to perform the free point on the 5.5 inch casing. AWS performed a bond log on the 5.5 inch casing from 1350 feet revealing bond to surface with no voids in the annulus of the 5.5 inch casing. Chipco tripped 2.375 inch tubing inside the 5.5 inch casing to 1354 feet and pumped a 61 sack 300 foot Class A Berea plug inside the casing from 1311 feet to 1011 feet. The cement was displaced with 3.9 barrels of fresh water. Chipco tripped 2.375 inch tubing to 502 feet and pumped a 102 sack 502 foot surface cement plug inside the 5.5 inch casing. Chipco tripped 2.375 inch tubing out and found that the plug had dropped to 502 feet. The backside of the 5.5 inch casing began to flow water. Decision was made and Chipco pumped a 30 sack class A cement plug and shut well in. |
0373870766 | 2016-08-02 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed Chipco LLC pump a 46 sack 400 foot Class A Clinton cement plug from 5203 feet to 4803 feet and displaced cement with 18.5 barrel of fresh water. Chipco tripped 2.375 inch tubing to 3730 feet and pumped a 60 sack 200 foot Class A Big Lime cement plug from 3730 feet to 3530 feet and cement was displaced with 13.6 barrels of fresh water. Chipco tripped tubing out and tripped in with their ripping tool to rip 5.5 inch casing. |
0523581696 | 2005-06-03 | Production Wells | No Violations | STATUS CHECK |
0651133820 | 2016-03-08 | Production Wells | No Violations | On the day of my inspection following up on NOV-670412454 & Complaint ID #5104, I witnessed the pumping unit was running with fluid going into the 100bbl tank. I placed call to Enervest requesting an update on the production of the well. |
0670412454 | 2015-08-25 | Production Wells | Violations Noted | On the day of my inspection following up on Complaint ID #5104, I met with landowner to locate said well. I witnessed the production equipment included a 100bbl tank, a horizontal separator and a drip all within an earthen dike. Oil contamination was present in the northeast corner of the dike. The well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, rods and pumping unit powered by electricity with all valves closed at the wellhead. Identification was present and production records were current reporting zero production for 2014. The well owner/operator shall submit a written plugging schedule to Doug Bennett at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. |
1085745040 | 2004-05-28 | Production Wells | No Violations | C/O FROM BELDON BLAKE, WILL NEED ID RE-POSTED WITHIN 60 DAYS. |
1089115332 | 2004-06-30 | Production Wells | No Violations | TANK ID RE-POSTED |
1181662701 | 2016-08-05 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed the surface plug had dropped to 200 feet. Chipco arrived and topped off the 5.5 inch casing and squeezed the annulus with a total of 60 sacks of Class A cement and closed the valves for the weekend. |
1229879086 | 2006-07-06 | Production Wells | No Violations | PRODUCING WELL |
143755070 | 2006-9-20 0:00: | PW | No Violations | |
1470145665 | 2016-08-01 | Plug / Plug Back | No Violations | On the day of my inspection following up on Compliance Notice-670412454 & Complaint ID #5104, I witnessed Chipco LLC was onsite and unseated the packer which was set at 5171 feet. Chipco tripped 2.375 inch tubing from wellbore and Appalachian Well Surveys (AWS) arrived. AWS tripped inside the 5.5 inch casing and perforated the Big Lime with 10 shots from 3736 feet to 3726 feet. Chipco began to trip 2.375 tubing back in and will commence plugging tomorrow. |
1470657808 | 2016-08-08 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed Chipco LLC open the well revealing zero pressure and the cement remaining at the surface. Chipco cut casing off 30 inches below grade, installed metal plate identifying well and began reclamation. Compliance Notice-670412454 & Complaint ID #5104 are now resolved as well has been plugged. |
1478729756 | 2016-04-06 | Production Wells | No Violations | On the day of my inspection following up on NOV-670412454 & Complaint ID #5104, I witnessed the power for the pumping unit was in the off position with the flowline on bypass to the tank. |
1550787290 | 2016-05-12 | Production Wells | No Violations | On the day of my inspection following up on NOV-670412454 & Complaint ID #5104, I witnessed the power for the pumping unit was in the off position with the flowline on bypass to the tank. I placed call to Enervest Superintendent Tim McConaha where he stated he is going to apply for a plug permit for the well. |
1893775479 | 2015-11-30 | Production Wells | No Violations | On the day of my inspection following up on NOV-670412454 & Complaint ID #5104, after receiving a response from Enervest wanting to make repairs and put well back in production with the work being completed by November 30, 2015, I witnessed that Berry Well Service Rig #1 was rigged up onsite and rods and tubing have been removed from wellbore. No personnel were onsite at the time of inspection. |
189468234 | 2016-12-5 0:00: | FR | No Violations | 1.00 |
1959548977 | 2011-06-20 | Production Wells | No Violations | Inspection revealed that well is equipped with pumping unit and tubing and rods and 4.5 production casing and 8 surface casing and 1-100 bbl tank, well was recently serviced(pump change) and dike was constructed around wellhead. |
1990866090 | 2004-01-08 | Production Wells | No Violations | STATUS CHECK |
24369050 | 2016-8-4 0:00:0 | PB | No Violations | 8.00 |
373870766 | 2016-8-2 0:00:0 | PB | No Violations | 6.50 |
523581696 | 2005-6-3 0:00:0 | PW | No Violations | |
651133820 | 2016-3-8 0:00:0 | PW | No Violations | 1.00 |
670412454 | 2015-8-25 0:00: | PW | No Violations | 1.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0670412454 | US-OH-127584 | 2016-08-12 | Well shall be plugged |
For data sources see[9]