If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-24274 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.92,"lon":-81.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Spencer Township | |
Operator Name: EQT PRODUCTION COMPANY | |
Well Pad ID: US-OH-000721 | |
Farm/Lease Name: NCD3 | |
License Status: Plugged Back | |
License Date: 2013-04-24 | |
Spud Date: 2013-09-13 | |
Spud Drilling Contractor: PIONEER DRILLING | |
Final Drill Date: 2013-09-25 | |
Well Total Depth: 7010.00 ft | |
Configuration: Vertical | |
Latitude: 39.920000 | |
Longitude: -81.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-04-24 | Proposed Formations:BLACK RIVER, Issued Date:4/24/2013, Expired Date:4/24/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Correction to Well | 2013-04-26 | CORRECTION TO FOOTAGE. |
Plugged Back | 2013-09-25 | |
Reached Total Depth | 2013-09-25 | |
Construction Permit Expires | 2015-04-24 | |
Completion Report Received | 2017-11-09 | |
Record Last Modified | 2017-11-14 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 05/22/2014 | 06/21/2014 | 6638 | 8,862,940.0 | 517233 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | AGA-24 | CUDD | Friction Reducer | Non-Hazardous | NA | 100 | 0.00304003 | 2545.62 |
SG-14G | CUDD | Gel | Solvent naphtha, (petroleum) heavy aliphatic | 64742-96-7 | 65 | 0.170802 | 143156 | |
I-22 | CUDD | Corrosion Inhibitor | Benzyl Chloride | 100-44-7 | 1 | 0.00002000 | 17.59 | |
Aromatic aldehyde | Proprietary | 30 | 0.000630006 | 527.82 | ||||
Quaternary ammonium compound | Proprietary | 5 | 0.000100001 | 87.97 | ||||
Isopropanol | 67-63-0 | 5 | 0.000100001 | 87.97 | ||||
Organic Sulfur Compound | Proprietary | 5 | 0.000100001 | 87.97 | ||||
Methanol | 67-56-1 | 5 | 0.000100001 | 87.97 | ||||
Oxyalkylated Fatty Acid | Proprietary | 30 | 0.000630006 | 527.82 | ||||
Haloalkyl heteropolycycle salt | Proprietary | 30 | 0.000630006 | 527.82 | ||||
Formic Acid | 64-18-6 | 60 | 0.00126001 | 1055.64 | ||||
XL-108 | CUDD | Cross Linker | Glutaraldehyde | 111-30-8 | 1 | 0.00045 | 379.46 | |
Hydrated Aluminum-magnesium Silicate (palygorskite) | 12174-11-7 | 5 | 0.00226 | 1897.29 | ||||
Crystalline Silica, Quartz | 14808-60-7 | 0.1 | 0.00005000 | 37.95 | ||||
FR-900 | CUDD | Friction Reducer | Non-Hazardous | NA | 100 | 0.0545905 | 45756.4 | |
MX-8 | Halliburton | Biocide | Bacteria Culture | N/A | 100 | 0.0125101 | 10482.3 | |
MSI-7 | CUDD | Scale Inhibitor | Hydrochloric Acid | 7647-01-0 | 9 | 0.00195002 | 1637.27 | |
Sand | CUDD | Proppant | Crystalline Silica | 14808-60-7 | 100 | 10.6661 | 8,939,630.0 | |
SP-Breaker | CUDD | Gel Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.00514005 | 4311.6 | |
XL-101 | CUDD | Cross Linker | Potassium Hydroxide | 1310-58-3 | 5 | 0.00226 | 1897.29 | |
Ethylene Glycol | 107-21-1 | 10 | 0.00453 | 3794.57 | ||||
Potassium Metaborate | 13709-94-9 | 30 | 0.01358 | 11383.7 | ||||
MX-5 | Halliburton | Biocide | Sodium Nitrate | 7631-99-4 | 60 | 0.0532205 | 44608.4 | |
FE-4 | CUDD | Iron Control | Citric Acid | 77-92-9 | 50 | 0.000890008 | 743.45 | |
MX 5-2350 | Halliburton | Surfactant | Ethoxylated Alcohols | Proprietary | 13 | 0.0178702 | 14974.5 | |
Methyl alcohol | 67-56-1 | 100 | 0.137431 | 115188 | ||||
Sulfonate | Proprietary | 10 | 0.0137401 | 11518.8 | ||||
Buffer-H | CUDD | Buffer Agent | Caustic Soda - Sodium Hydroxide | 1310-73-2 | 50 | 0.00833007 | 6978.55 | |
15%-HCl | CUDD | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0825507 | 69189.8 | |
Water | CUDD | Carrier | Water | 7732-18-5 | 100 | 88.0866 | 73,828,300.0 |
For data sources see[3]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | EQT PRODUCTION COMPANY | Brine | 11747 | 99 |
2015 | EQT PRODUCTION COMPANY | Brine | 8297 | 360 |
2016 | EQT PRODUCTION COMPANY | Brine | 3479 | 270 |
2017 | PIN OAK ENERGY PARTNERS LLC | Brine | 1199 | 264 |
2018 | PIN OAK ENERGY PARTNERS LLC | Brine | 1342 | 360 |
2019 | PIN OAK ENERGY PARTNERS LLC | Brine | 329 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1026923860 | 2019-11-21 0:00 | PW | No Violations | 0.30 |
-1084410066 | 2019-2-6 0:00:0 | PW | No Violations | 0.50 |
-1371035344 | 2014-9-15 0:00: | PL | No Violations | 0.50 |
-177526646 | 2020-3-5 0:00:0 | PW | No Violations | 0.50 |
-1864850778 | 2018-3-29 0:00: | PW | No Violations | 0.50 |
-1875045930 | 2015-12-7 0:00: | PW | No Violations | 1.00 |
-2121047641 | 2015-4-6 0:00:0 | PW | No Violations | 1.00 |
-22267445 | 2019-5-2 0:00:0 | PW | No Violations | 0.20 |
-377376930 | 2019-2-5 0:00:0 | PW | No Violations | 0.50 |
-479662154 | 2017-6-23 0:00: | PW | No Violations | 0.50 |
-524559789 | 2016-12-16 0:00 | PW | No Violations | 0.50 |
-569294853 | 2020-3-5 0:00:0 | PW | No Violations | 1.00 |
-917948778 | 2016-4-27 0:00: | PW | No Violations | 0.50 |
0377376930 | 2019-02-05 | Production Wells | No Violations | The inspection is just on well head only. Luke Mallet accompanied me on the inspection and revealed the first compressor feeds the this well PN-4274 and PN- 4276. The well is compressing gas down casing and feeding oil and gas back into the tubing. The gauge on the well head is 750 psi and will get measurement tomorrow. The red valves are safety valve shut offs and hold true on the Gas Production Units. |
0453730242 | 2018-03-29 | Production Wells | No Violations | On the day of my inspection accompanied by ODNR Inspector Doug Bennett, I witnessed the production equipment included a sand trap, and a GP Unit. A combustor, a sand purge tank, 12- 400 barrel tanks and 140 barrel tank shared with the 34059243100100 NCD3 580035 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. Proper identification was present and production report was up to date. |
0479662154 | 2017-06-23 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 3-compressor units, 12-400 barrel tanks and a 140 barrel tank shared with the 34059243100100 NCD3 580035 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. Identification was present and production records were current. |
0524559789 | 2016-12-16 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 3-compressor units, 12-400 barrel tanks and a 140 barrel tank shared with the 34059243100100 NCD3 580035 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. |
0693592932 | 2019-01-29 | Production Wells | No Violations
[1] Gas production unit, [1] sand trap, [12] 400-barrel steel tanks, [1]140-barrel steel tank, cyclone combustor and a compressor. The two outside compressors were running and the center one was not. | |
0885226116 | 2018-08-15 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the wells were equipped with a production tree style wellhead and were equipped to produce with an enhanced recovery method by injecting produced gas into the 5.5-inch diameter production casing. The well appeared to be producing. The production equipment consisted three sand traps, three gas production units, twelve 400-barrel tanks, a sand purge tank, one 200-barrel tank, one combustor, and three compressors. Identification was at the well entry, the wellhead, and tank battery. Production records were current. Accompanied by ONDR inspector Pat Shreve and ODNR Regional Supervisor Brent Bear. |
0917948778 | 2016-04-27 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 12-400bbl tanks and 140bbl tank shared with the 34059243100100 NCD3 580035 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. The impoundment has been closed and restored to grade with seed and mulch in place. |
1081770881 | 2018-08-20 | Production Wells | No Violations | The inspection was conducted under an enhanced production set-up. The well is equipped with a tree style well head and all valves are open. The production equipment consists of one Gas Production Unit, [12] 400-barrel steel tanks enclosed within a galvanized impoundment. The gas vapors are sent thru a gas Cyclone and burned. There is a compressor to compress gas and send the gas back down the tubing annulus. |
1084410066 | 2019-02-06 | Production Wells | No Violations | The inspection revealed that Pin Oak (Luke Mallet) was pumping out the cellar and that the pressure gauge being monitored on the 9 5/8 casing on the 2-inch port which had 750 psi is on the pressure gauge. |
1129062478 | 2013-09-11 | Drill / Deepen / Reopen | No Violations | |
1351494022 | 2014-08-12 | Preliminary Restoration | No Violations | On the day of my inspection the site passed preliminary restoration according ORC 1509.072A. |
1371035344 | 2014-09-15 | Preliminary Restoration | No Violations | On the day of my inspection I witnessed that EQT was preparing for flow back on Wednesday and the site passed preliminary restoration according to ORC 1509.072A. |
1384791319 | 2013-11-18 | Drill / Deepen / Reopen | No Violations | On the day of my inspection, I was given a twenty four hour notice from EQT that would be starting to solidify and cover the drilling pits. |
1558950220 | 2018-08-15 | Production Wells | No Violations | Brent Bear and I accompanied Austin Gutridge on the inspection. The inspection revealed the well is equipped with a large flange style well head with 2 master tubing valves and 1 flowline valve. The well is an enhanced gas system by compressing gas down tubing annulus and produce the oil thru the tubing. The tank site consists of [12] 400-barrel steel tanks, [1] 40-barrel steel tank enclosed within a Galvanized and rubber impoundment. There is a gas production unit and a gas cyclone. The compressors are over by the entrance of the pad. |
1572006374 | 2019-03-12 | Production Wells | No Violations | The inspection revealed the well is equipped with a Cactus flanged well head assembly. The 2--inch casing. The stainless-steel riser and gauge were placed on the well head and the pressure is 700 psi. |
1771239713 | 2018-09-05 | Production Wells | No Violations | The purpose of my inspection was a status check. I was contacted by Pin Oak well tender Luke Mallet. Mr. Mallet stated that he has installed gauges for annular pressure monitoring. During my inspection the wells were equipped with a production tree style wellhead and were equipped to produce with an enhanced recovery method by injecting produced gas into the 5.5-inch diameter production casing. Production valves were in the open position. Annular pressure monitoring was now present. The production equipment consisted three sand traps, three gas production units, twelve 400-barrel tanks, a sand purge tank, one 200-barrel tank, one combustor, and three compressors. Identification was at the well entry, the wellhead, and tank battery. Production records were current. |
1860887602 | 2019-02-13 | Production Wells | No Violations | |
1864850778 | 2018-03-29 | Production Wells | No Violations | On the day of my inspection I accompanied ODNR Inspector Jeff Adams please see his report for details. |
1875045930 | 2015-12-07 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 12-400bbl tanks and 140bbl tank shared with the 34059243100100 NCD3 580035 and 34059242760100 NCD3 580010 within containment. The well was equipped with a production tree producing by gas injection and was online at the time of inspection. |
1882352471 | 2018-08-20 | Production Wells | No Violations | The purpose of my inspection today was a status check. On 8/15/18 I met in person with Luke Mallet the well tender for Pinn Oak. I explained to Mr. Mallett that gauges will need installed to properly monitor annular pressures. Mr. Mallett was unsure of the current annular pressures for each well and he stated he will have the work completed in two weeks. During my inspection today, the gauges have not yet been installed. A follow up inspection will be conducted. |
1946309328 | 2014-09-18 | Completion Testing | No Violations | On the day of my inspection I witnessed that flow back had begun at 8:30 am with 1100psi gas was being sent down the salesline, production water to the frac tanks and condensate to the storage tanks. Met with Company Man Jay Johnston and completed walk around. Flow back will begin on the 580010 and 580035 later today and continuing for 4 days. |
2121047641 | 2015-04-06 | Production Wells | No Violations | On the day of my inspection accompanied by ODNR Inspector Matt Fulk, I witnessed that the production equipment included a sand trap, a GP Unit, a combustor, a sand purge tank, 12-400bbl tanks and 140bbl tank shared with the 34059243100000 NCD3 580035 and 34059242760000 NCD3 580010 within containment. The well was equipped with a production tree and was online at the time of inspection. |
453730242 | 2018-3-29 0:00: | PW | No Violations | 0.50 |
693592932 | 2019-1-29 0:00: | PW | No Violations | 0.20 |
885226116 | 2018-8-15 0:00: | PW | No Violations | 0.40 |
For data sources see[6]