Well Details

Well ID: 34-085-21308
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OSAIR INC
Well Pad ID:
Farm/Lease Name: RUFF
License Status: Producing
License Date: 2011-05-04
Spud Date: 2011-06-23
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2011-07-02
Well Total Depth: 3496.00 ft
Configuration: Vertical
Latitude: 41.570000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-05-04 Proposed Formations:CLINTON, Issued Date:5/4/2011, Expired Date:5/3/2013 12:00:00 PM, Drilling unit acres:22.59, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-07-02
Completion Report Received 2011-11-09
Change of Owner 2012-02-08 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 957, OSAIR INC
Construction Permit Expires 2012-05-03
Change of Owner 2013-12-23 Operator changed from 957, OSAIR INC to 9215, OSAIR INC. OSAIR CANCELED STATUS REINSTATED WITH NEW OWNER NUMBER. WELLS TRANSFERRED TO NEW OWNER NUMBER.EAF
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-19 3313 3353 33
3313 3353 33
3313 3353 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-07-22 H2O 0 180030 Gal 100000 Universal Well Services Inc. N2 507000 GALLONS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 OSAIR INC 12397.00 17.00 142
2012 OSAIR INC 19481.00 139.00 366
2013 OSAIR INC 11185.00 128.00 365
2014 OSAIR INC 9134.00 119.00 365
2015 OSAIR INC 5476.00 0.00 365
2016 OSAIR INC 210.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 OSAIR INC Brine 770 142
2012 OSAIR INC Brine 460 366
2013 OSAIR INC Brine 345 365
2014 OSAIR INC Brine 340 365
2015 OSAIR INC Brine 0 365
2016 OSAIR INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1949176860 2011-6-27 0:00: UD No Violations
-2034852559 2019-12-17 0:00 UP No Violations
0618994568 2017-09-05 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated battery in separate board-on-board enclosures. The enclosure gates were locked. The load-line valves were locked and secure. The secondary containment was intact and free from signs of spills, leaks, or other problems. The gravel-paved access road was in good condition. I noted that there was some leaked oil under the 2-inch hammer union at the wellhead and I notified the well owner.
1307048595 2011-06-02 Urban Drill / Deepen / Reopen No Violations Building the drilling site. Tree removal company on-site clearing trees and brush. Lease road being built. ID sign at lease road. Boundaries are staked with flagging tape.
1308851710 2011-06-23 Urban Drill / Deepen / Reopen No Violations Conductor cementing. ID sign and permit posted at entrance to lease road. Lease road stable. Bridge placed over stream is in place, graded and seeded. Sediment controls are in place surrounding the site. Pits are in good repair. Spoke with Tim Reilly regarding fencing the perimeter of the site, he stated he would have it fenced by the end of the day. Rig set 1 jt new R-3 32# 11.75 casing to 42.3 ft. Casing will be cut down to approx 32. Hole is 15 TD 39. Hole is static. Universal on-site to cement conductor, broke circulation and ran 50 sks Class A 3% CaCl and 1/2lb flake. Cement circulated to surface, displaced cement to 27 using 3.3 bbl fresh water. 6 bbl good cement returned to surface.
1309209679 2011-06-24 Urban Drill / Deepen / Reopen No Violations Present to witness surface cementing. Pits in good repair and fenced. Great Plains drilled 11 hole to 240 TD. Set 8.625 new R-3, 24# casing at 209. Circulated on hole for one hour waiting for cement to arrive. Universal broke circulation and pumped 110 sks GasBlock cement and displaced to 199 using 12 bbl fresh water. 12 bbl good cement returned and held at surface.
1310137104 2011-07-08 Urban Drill / Deepen / Reopen No Violations Pits solidified and buried.
1311942659 2011-07-22 Urban Drill / Deepen / Reopen No Violations On-site at 7:30 AM for frack job. Universal Well Services onsite setting up for the job. Sediment controls in place, site in good repair. Nitrogen frack. Formation broke down at 2149 psi at 8:37 AM. Job went according to plan. Annulus showed no sign of leakage. Avg pressure 2212 psi, Avg rate 9.95 bpm, ISIP 890 psi, 10-min SIP 1228 psi, vol. fluid 18,030 gal, 1000 sks sand used, flush volume 2287 gal
1333460972 2012-03-19 UrbanProduction Wells No Violations My inspection today found that this site has been graded and seeded but the vegetation needs time to become established. Landscaping has not been installed at this time. A pop-off valve has been installed on the annulus. The lease road is stable and in good repair.
1351199180 2012-09-12 UrbanProduction Wells No Violations The unit consists of a 2-tank battery (TB) with mechanical separator enclosed in a 6-foot fence. The spacing is in accordance with the rule, and the valving and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a mechanical plunger lift and is located 75 feet north of the TB. The tank battery dike is adequate. Locks and ID are good. No violations noted.
1461774623 2016-04-27 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and battery are located via a dedicated, unpaved access road which enters from White Road. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system and tank battery in separate board-on-board enclosures. Enclosure gates were locked and secure. The tank load-line valves were locked and secure. Tank lids were closed and secure. Secondary containment was present and intact. I observed the following safety/maintenance deficiencies: The surface casing nipple is exposed but not gauged as required by permit condition. The ID signage identifies John D. Oil & Gas as the current owner which conflicts with current record keeping indicating Osair, Inc. The owner must complete the following by May 27, 2016: Properly gauge the surface casing nipple, update signage to reflect the current owner. Contact Inspector Stephen Tompkins at 330-907-4647 with question regarding this inspection.
1870342237 2015-02-25 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located via a dedicated lease road that runs north from White Road. A portion of the lease road is shared with a telecommunications tower access road. The wellhead is comprised of a plunger lift system and battery (2 100-barrel steel tanks) in separate board-on-board enclosures. Fittings and connections at the wellhead and battery are secure. Load lines are secure and plugged. 12 to 15 inches of snow cover obscures some surficial features and areas. The area surrounding the well and battery is mostly wooded, and lies adjacent to I-271.
1949176860 2011-06-27 Urban Drill / Deepen / Reopen No Violations Witnessed BOP test with Steve Ochs present. BOP in good working order. BOP passed.
1994366096 2017-04-17 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for improper ID and missing nipple and gauge at the surface casing which was a permit condition at the time of the issuance of the original drilling permit. At the time of this inspection, I observed the following: the ID had been updated to reflect the change in ownership, although the ID signage remains missing information required under OAC 1501:9-9-05(E)(1). The surface casing nipple has been properly gauged as required under the permit condition. The load-line valves were locked and secure. The enclosure gates were locked. The areas surrounding the wellhead and battery were free from signs of impact or observable degradation resulting from the on-going production activity. I have attempted to contact the owner regarding the need for upgrade to the ID signage and, at the time of the filing of the report, have not received a response.
526715847 2020-5-1 0:00:0 UP No Violations
618994568 2017-9-5 0:00:0 UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1461774623 US-OH-113364 2016-06-01 ID (a-i)
1461774623 US-OH-113365 2016-06-01 General Safety

For data sources see[9]