Well Details

Well ID: 34-087-20438
Loading map...
Country: United States
State: Ohio
County: Lawrence
Municipality: Mason Township
Operator Name: PILLAR ENERGY LLC
Well Pad ID:
Farm/Lease Name: PAYNE PEARL V
License Status: Active Injection
License Date: 1992-09-29
Spud Date: 1988-08-01
Spud Drilling Contractor: GARD DRILLING
Final Drill Date: 1988-08-02
Well Total Depth: 745.00 ft
Configuration: Vertical
Latitude: 38.630000
Longitude: -82.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-07-18 Issued Date 7/18/88 Expired Date 7/18/89 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00745 Proposed Drill Depth 00745
Original Spud 1988-08-01 CONVERT 10-3-92 PERMIT EXPIRED.
Completed 1988-08-02 CONVERT 10-3-92 PERMIT EXPIRED.
Reached Total Depth 1988-08-02 CONVERT 10-3-92 PERMIT EXPIRED.
CO 1988-08-25 1089 MITCHELL ENERGY CORP GeoDate 7/18/88
Completion Report Received 1988-08-25 CONVERT 10-3-92 PERMIT EXPIRED.
First Injection 1988-08-25 CONVERT 10-3-92 PERMIT EXPIRED.
CO 1992-09-29 1089 MITCHELL ENERGY CORP GeoDate 9/29/92
Enhanced Recovery 1992-09-29 Issued Date 9/29/92 Expired Date 9/29/93 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth Proposed Drill Depth
Annulus Pressure Monitoring Approved 1992-11-24 CONVERT 10-3-92 PERMIT EXPIRED.
Construction Permit Expires 1993-09-29 CONVERT 10-3-92 PERMIT EXPIRED.
Change of Owner 1999-10-22 Operator changed from 1089, MITCHELL ENERGY CORP to 3793, ENERGY SEARCH INC
Last Compliance Report 2000-02-25 CONVERT 10-3-92 PERMIT EXPIRED.
Change of Owner 2008-02-26 Operator changed from 3793, ENERGY SEARCH INC to 1388, NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2016-02-24 Operator changed from 7578, ENERVEST OPERATING LLC to 9619, PILLAR ENERGY LLC
Record Last Modified 2017-02-15 CONVERT 10-3-92 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-02-25 627 649 1
627 649 1
627 649 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 223 Bbl 12900 FRAC WITH 223 BBLS OF GELLED H2O AND 12,900# OF SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 MITCHELL ENERGY CORP 0.00 630.00 118
1989 MITCHELL ENERGY CORP 0.00 1229.00 355
1990 MITCHELL ENERGY CORP 12.00 720.00 365
1991 MITCHELL ENERGY CORP 12.00 436.00 346
1992 MITCHELL ENERGY CORP 11.00 484.00 324
1993 MITCHELL ENERGY CORP 0.00 0.00 0
1994 MITCHELL ENERGY CORP 0.00 0.00 365
1995 MITCHELL ENERGY CORP 0.00 0.00 0
1997 MITCHELL ENERGY CORP 0.00 0.00 0
1998 MITCHELL ENERGY CORP 0.00 0.00 0
1999 ENERGY SEARCH INC 0.00 0.00 60
2000 ENERGY SEARCH INC 0.00 0.00 365
2008 EXCO - NORTH COAST ENERGY INC 0.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 0.00 0.00 0
2010 ENERVEST OPERATING LLC 0.00 0.00 0
2011 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 MITCHELL ENERGY CORP Brine 26 118
1989 MITCHELL ENERGY CORP Brine 117 355
1990 MITCHELL ENERGY CORP Brine 144 365
1991 MITCHELL ENERGY CORP Brine 361 346
1992 MITCHELL ENERGY CORP Brine 297 324
1993 MITCHELL ENERGY CORP Brine 0 0
1994 MITCHELL ENERGY CORP Brine 0 365
1995 MITCHELL ENERGY CORP Brine 0 0
1997 MITCHELL ENERGY CORP Brine 0 0
1998 MITCHELL ENERGY CORP Brine
1999 MITCHELL ENERGY CORP Brine
2000 ENERGY SEARCH INC Brine 365
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 0
2010 ENERVEST OPERATING LLC Brine 0 0
2011 ENERVEST OPERATING LLC Brine 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1030049379 2017-6-7 0:00:0 SW No Violations
-1215986078 2015-4-6 0:00:0 ER No Violations 0.50
-1277553933 2004-11-3 0:00: SW No Violations
-1279248998 2013-10-21 0:00 ER No Violations 0.50
-1298696730 2013-12-11 0:00 SC No Violations 2.00
-1389488328 2011-4-6 0:00:0 ER No Violations
-1413591800 2010-12-30 0:00 ER No Violations
-1483636873 2007-5-31 0:00: ER No Violations
-149554210 2019-5-28 0:00: ER No Violations 1.00
-1555707384 2012-12-28 0:00 ER No Violations 2.30
-1596219828 2020-7-20 0:00: ER No Violations 0.50
-1616539057 2020-6-17 0:00: ER No Violations 0.40
-1655104043 2006-11-21 0:00 ER No Violations
-1835946439 2005-9-20 0:00: ER No Violations
-1880676247 2003-2-6 0:00:0 ER No Violations
-1967215915 2013-1-7 0:00:0 SC No Violations 2.50
-1968730941 2007-2-23 0:00: ER No Violations
-1991357609 2009-8-17 0:00: ER No Violations
-2058698062 2014-2-13 0:00: ER No Violations 1.50
-2059284144 2019-10-15 0:00 ER No Violations 0.40
-2127062742 2004-3-4 0:00:0 SW No Violations
-328405040 2006-3-16 0:00: ER No Violations
-542694396 2004-1-28 0:00: SW No Violations
-629316975 2008-1-23 0:00: ER No Violations
-641144324 2014-11-10 0:00 ER No Violations 0.70
-684143806 2013-5-3 0:00:0 ER No Violations 0.70
-690441411 2010-3-8 0:00:0 ER No Violations
-698905952 2010-6-7 0:00:0 ER No Violations 1.00
-784282316 2008-7-17 0:00: ER No Violations
-806196880 2007-9-25 0:00: ER No Violations
-823408389 2012-8-21 0:00: ER No Violations
-857441075 2019-2-19 0:00: ER No Violations 1.00
-86061179 2006-5-24 0:00: ER No Violations
-863336367 2004-5-20 0:00: SW No Violations
000PL14074 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0086061179 2006-05-24 Enhanced Recovery Project No Violations Within limits.
0108087242 2011-12-09 Enhanced Recovery Project No Violations Accompanied Jon Scott for ERP training. Site clean, not exceeding max injection.
0129550261 2015-10-13 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pump, injection pressure, and annulus pressure. Identification posted at the well.
0131237092 2016-08-25 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
0185831542 2005-02-09 Salt Water Injection Well No Violations Within limits.
0205460118 2006-08-15 Enhanced Recovery Project No Violations Within limits - lower pressure because well has been shut in for a day. Drip leaking.
0323483513 2018-03-19 Salt Water Injection Well No Violations I was on location today to check the pressures of this salt water injection well. The annulus pressure was 130 psi, the injection tubing pressure was 160 psi. No violations were noted during my inspection.
0328405040 2006-03-16 Enhanced Recovery Project No Violations Slightly over - had producer shut well in
0338650887 2003-02-06 Enhanced Recovery Project Violations Noted Injection pressure measured was 81 psi over maximum. Notified operator.
0372735459 2004-10-28 Salt Water Injection Well No Violations Within limits.
0528026493 2010-09-13 Enhanced Recovery Project No Violations Good identification. No violations observed.
0542694396 2004-01-28 Salt Water Injection Well No Violations
0570319285 2005-11-22 Enhanced Recovery Project No Violations passed.
0593830489 2006-01-24 Enhanced Recovery Project No Violations Pressures below maximum allowable; pressure on the annulus.
0622016108 2003-06-19 Enhanced Recovery Project Violations Noted The injection pressure measured was 258 psi, which exceeds the maximum allowable injection pressure of 191 psi.

On June 19, 2003, Tim Ross was informed of the violation and advised to immediately decrease the injection pressure below 191 psi.

0629316975 2008-01-23 Enhanced Recovery Project No Violations Pressure regulators made by Jordan Valves have been installed and are working great. The valves have a max. back pressure of 400psi, and a max. working pressure of 600psi. They are being set slightly below max. injection pressures. Well id missing. I told Jim Ross about it.
0641144324 2014-11-10 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, injection pump, injection pressure and annulus pressure. Good identification on the well.
0684143806 2013-05-03 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure. Good identification. Access road has been graded.
0687712522 2011-07-20 Enhanced Recovery Project No Violations Hole in top joint of tubing. Francis Brothers service rig on well. Cut off tubing, then spear tubing and release packer. Pull to next collar and replace top joint of tubing. Reset packer , (at 21,000 lbs) and fill annulus with fresh water and corrosion inhibitor. Test at 315 psi for 15 minutes. Good test.
0690441411 2010-03-08 Enhanced Recovery Project No Violations Good identification. No problems observed during inspection.
0698905952 2010-06-07 Enhanced Recovery Project No Violations Well id for Exco-North Coast, Needs to have Enervest information and contact phone numbers. I have talked to Jim Ross (Enervest contractor) about this needing to be changed as soon as possible.
0732277957 2012-04-05 Enhanced Recovery Project No Violations No violations at the time of inspection.
0733535241 2003-10-08 Enhanced Recovery Project No Violations Well is in compliance..
0778765355 2008-06-12 Enhanced Recovery Project No Violations No violations at this time.
0779875872 2005-04-28 Enhanced Recovery Project No Violations Passed
0784282316 2008-07-17 Enhanced Recovery Project No Violations Good Identification. No violations at this time.
0806196880 2007-09-25 Enhanced Recovery Project No Violations No violations at this time.
0823408389 2012-08-21 Enhanced Recovery Project No Violations UIC Training and well inspection. Accompanied by Morgan Button MRI 2. Injection pump is off line due to maintenance.
0850745997 2018-09-04 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well. The containment dike is free of fluids.
0857441075 2019-02-19 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
0863336367 2004-05-20 Salt Water Injection Well No Violations Within allowable limits.
1030049379 2017-06-07 Salt Water Injection Well No Violations Salt water injection well inspection. The annulus pressure was 63 PSI, the injection tubing pressure was 158 PSI. No violations noted.
1057612158 2004-11-03 Enhanced Recovery Project No Violations Passed.
1057612158150273 2004-11-3 0:00: ER No Violations
1057612158175038 2004-11-3 0:00: PW No Violations
108087242 2011-12-9 0:00: ER No Violations 0.30
1215986078 2015-04-06 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Walked injection line to well. Identification posted at the well.
1258557977 2009-11-04 Enhanced Recovery Project No Violations Good Identification. No violations were observed.
1277553933 2004-11-03 Salt Water Injection Well No Violations Random pressure check.
1279248998 2013-10-21 Enhanced Recovery Project No Violations Inspected the injection wells in this ERP field with Jon Scott. The sign for this well are in good shape. Parts of the wellhead plumbing are not wrapped in insulation. Return pipe on wellhead from pump house is spalding badly. Will need to be replaced. No leaks were detected at this time.
129550261 2015-10-13 0:00 ER No Violations 0.70
1298696730 2013-12-11 Surface Facility Construction No Violations Inspected the changes that have been made to the pump house injection line manifolds and the change over to a different injection pump. Inspected the unloading pad, containment dike and tanks.
131237092 2016-8-25 0:00: ER No Violations 1.50
1356718842 2012-12-28 Enhanced Recovery Project No Violations Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Accompanied by Morgan Button MRI 2.
1363349242 2013-03-14 Enhanced Recovery Project No Violations Jon Scott and I conducted the bimonthly inspection for this ERP field. We split up to cover more ground and try to complete this inspection in a timely manor. Wellhead identification sign is in good shape. Pipe and wellhead wrapped with silver coated insulation.
1374001791 2013-07-15 Enhanced Recovery Project No Violations Bimonthly UIC monitoring of Greasy Ridge ERP injection wells with Jon Scott. Wellhead and well identification sign are in good shape.
1377578258 2015-06-23 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, pump house, injection pressure and annulus pressure. Good identification posted at the well.
1378413664 2013-09-05 Enhanced Recovery Project No Violations Jon Scott and I performed the bimonthly UIC inspection on the injection wells in this field. There were no leaks and the identification sign was in good shape.
1389488328 2011-04-06 Enhanced Recovery Project No Violations No violations at this time.
1392328621 2014-02-13 Enhanced Recovery Project No Violations Well injection line was shut off and the pressure regulator was replaced.
1413591800 2010-12-30 Enhanced Recovery Project No Violations Has Enervest identification.
1452269491 2016-01-07 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
1474026426 2016-03-30 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy.
1478553869 2016-11-07 Enhanced Recovery Project Violations Noted An inspection of the well revealed a stream of brine coming between the 1/4 inch valve for the injection pressure gauge and the injection line. A 2 inch ball valve on the injection line was closed to stop the leak. High range Quantabs were used to delineate the contaminated area. All Quantabs were maxed out (Levels over 6,215 ppm Cl) The contaminated area is 25 feet by 32 feet by 15 feet by 27 feet. The contamination originates at the wellhead and flows down slope to the access road. The brine flow was stopped by deep ruts in the access road. Doug Miller (well tender) was notified and responded to the well site. A call was made to Jeff Isner (Pillar Energy) a voice message was left for Jeff. All brine contaminated soil must be removed and taken to an EPA approved landfill for disposal.
1478784892 2016-11-08 Enhanced Recovery Project No Violations Compliance notice # 1478553869 follow up inspection. The leaking 1/4 inch nipple has been replaced. The contaminated soil was removed and placed into a plastic lined dump truck for disposal. The site was field tested with Quantabs during excavation by the UIC Inspector, Lawrence County Inspector and the South West Emergency Operations Coordinator. The site has been graded for positive drainage. Lime was applied to the location. The injection pressure and annulus pressure was recorded.
1483636873 2007-05-31 Enhanced Recovery Project No Violations No violations at this time.
1528847252 2017-04-27 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pump, injection pressure and annulus pressure. The injection pressure was 12 psi. I talked to Mike Carr about this low pressure and Mike stated that they had the injection pump off line for service and had just resumed injection operations. The containment dike was free of fluids. Identification was posted at the well.
1555707384 2012-12-28 Enhanced Recovery Project No Violations Inspected injection tubing and annulus pressures for this well with Jon Scott. Well identification sign in good shape.
1565245914 2008-11-12 Enhanced Recovery Project No Violations Good id. No problems observed.
1632388829 2009-05-12 Enhanced Recovery Project No Violations Good id. No violations were observed at time of inspection.
1655104043 2006-11-21 Enhanced Recovery Project No Violations No problems
1709246078 2018-10-24 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well. The containment dike is free of fluids.
1741303486 2018-05-24 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pumps, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
1823772970 2007-04-05 Enhanced Recovery Project No Violations No problems, Jim Ross has grated the lease roads.
1833154932 2008-09-18 Enhanced Recovery Project No Violations Good id. No violations at this time.
1835946439 2005-09-20 Enhanced Recovery Project No Violations OK
185831542 2005-2-9 0:00:0 SW No Violations
1879171227 2008-03-25 Enhanced Recovery Project No Violations No violations were observed. The new pressure regulator is working well.
1880676247 2003-02-06 Enhanced Recovery Project Violations Noted FOLLOW UP TO NOV # 338650887 Injection pressure measured was 81 psi over maximum. Notified operator.
1899936505 2004-04-29 Salt Water Injection Well No Violations Well is within pressure limits
1964202601 2016-04-19 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy.
1967215915 2013-01-07 Surface Facility Construction No Violations Concrete dike pad has been poured. Concrete block and mortar is on site. Extended concrete apron to unloading pad.
1968661993 2014-08-18 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, walked the injection line, checked the injection pressure and annulus pressure. Good identification at wellhead.
1968730941 2007-02-23 Enhanced Recovery Project No Violations No problems at this time.
1976772320 2014-06-12 Salt Water Injection Well No Violations No noted violations.
1991357609 2009-08-17 Enhanced Recovery Project No Violations Good identification. No violations observed during inspection.
205460118 2006-8-15 0:00: ER No Violations
2058698062 2014-02-13 Enhanced Recovery Project Violations Noted Inspected containment dike, tanks, Pump house, injection pressure and annulus pressure. Good identification at well. Injection pressure was 220 psi. that is over the max allowable injection pressure of 191 psi. I told Jonathan Ross and he shut in the well and then checked the pressure regulator that is installed at the wellhead on the injection tubing. The regulator had frozen. Jonathan replaced the regulator.
2083982403 2009-02-25 Enhanced Recovery Project No Violations Good id. No violations observed during inspection.
2127062742 2004-03-04 Salt Water Injection Well No Violations Tested within range
2133097299 2004-08-08 Salt Water Injection Well No Violations Within specified range
23469450 2019-9-5 0:00:0 ER No Violations 1.00
323483513 2018-3-19 0:00: SW No Violations 0.40
338650887 2003-2-6 0:00:0 ER No Violations
372735459 2004-10-28 0:00 SW No Violations
528026493 2010-9-13 0:00: ER No Violations 0.50
570319285 2005-11-22 0:00 ER No Violations
593830489 2006-1-24 0:00: ER No Violations
622016108 2003-6-19 0:00: ER No Violations
687712522 2011-7-20 0:00: ER No Violations
732277957 2012-4-5 0:00:0 ER No Violations 0.50
733535241 2003-10-8 0:00: ER No Violations
746427654 2020-1-22 0:00: ER No Violations 1.00
778765355 2008-6-12 0:00: ER No Violations
779875872 2005-4-28 0:00: ER No Violations
850745997 2018-9-4 0:00:0 ER No Violations 0.30
PL14074 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0338650887 US-OH-123538 2003-02-19 Exceeding maximum allowable injection pressure
0622016108 US-OH-127022 2003-06-23 Exceeding maximum allowable injection pressure
1478553869 US-OH-113676 2016-11-23 Pollution/Contamination
1880676247 US-OH-118880 2003-02-19 Exceeding maximum allowable injection pressure
2058698062 US-OH-120975 2014-02-14 Exceeding maximum allowable injection pressure

For data sources see[9]