Well Details

Well ID: 34-087-20461
Loading map...
Country: United States
State: Ohio
County: Lawrence
Municipality: Mason Township
Operator Name: PILLAR ENERGY LLC
Well Pad ID:
Farm/Lease Name: MAYER J
License Status: Active Injection
License Date: 1997-06-10
Spud Date: 1995-11-29
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 1995-12-02
Well Total Depth: 875.00 ft
Configuration: Vertical
Latitude: 38.620000
Longitude: -82.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1990-08-15 Issued Date 8/15/90 Expired Date 8/15/91 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00000 Proposed Drill Depth 00000
CO 1995-11-02 1089 MITCHELL ENERGY CORP GeoDate 11/2/95
Oil and Gas 1995-11-02 Issued Date 11/2/95 Expired Date 11/1/96 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00875 Proposed Drill Depth 00875
Original Spud 1995-11-30 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
Completed 1995-12-02 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
Reached Total Depth 1995-12-02 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
CO 1996-02-06 1089 MITCHELL ENERGY CORP GeoDate 8/15/90
Construction Permit Expires 1996-11-01 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
CO 1997-06-10 1089 MITCHELL ENERGY CORP GeoDt 6/10/97
Enhanced Recovery 1997-06-10 Issued Date 6/10/97 Expired Date 6/10/98 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth Proposed Drill Depth
Annulus Pressure Monitoring Approved 1997-09-18 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
First Injection 1997-09-18 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
Completion Report Received 1997-10-14 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
Last Compliance Report 2000-03-02 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97
Change of Owner 2004-05-25 Operator changed from 1089, MITCHELL ENERGY CORP to 3793, ENERGY SEARCH INC.

THIS WELL WAS ON THE CHANGE OF OWNER FORM FROM MITCHELL TO ENERGY SEARCH BUT WAS MISSED. LINDA SLATER BROUGHT IT TO MY ATTENTION AND I TRANSFERRED IT TODAY. MM

Change of Owner 2008-12-10 Operator changed from 3793, ENERGY SEARCH INC to 1388, EXCO - NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2016-02-24 Operator changed from 7578, ENERVEST OPERATING LLC to 9619, PILLAR ENERGY LLC
Record Last Modified 2017-02-15 Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-03-02 764 785 1
764 785 1
764 785 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 226 Bbl 20100 FRAC WITH WATER AND SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 MITCHELL ENERGY CORP 0.00 0.00 0
1996 MITCHELL ENERGY CORP 0.00 1182.00 306
1997 MITCHELL ENERGY CORP 0.00 0.00 307
1998 MITCHELL ENERGY CORP 0.00 0.00 0
1999 ENERGY SEARCH INC 0.00 0.00 60
2000 ENERGY SEARCH INC 0.00 0.00 365
2001 ENERGY SEARCH INC 0.00 3388.00 365
2002 ENERGY SEARCH INC 0.00 31.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 MITCHELL ENERGY CORP Brine 0 0
1996 MITCHELL ENERGY CORP Brine 212 306
1997 MITCHELL ENERGY CORP Brine 0 307
1998 MITCHELL ENERGY CORP Brine
1999 MITCHELL ENERGY CORP Brine
2000 ENERGY SEARCH INC Brine 365
2001 ENERGY SEARCH INC Brine 0 365
2002 ENERGY SEARCH INC Brine 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1031290594 2013-10-21 0:00 ER No Violations 0.50
-1079519748 2019-11-29 0:00 ER No Violations 1.00
-1110659926 2008-9-18 0:00: ER No Violations
-117884162 2004-1-28 0:00: SW No Violations
-1262327603 2016-11-8 0:00: ER No Violations 1.00
-1264634974 2010-6-7 0:00:0 ER No Violations 1.00
-1324936516 2006-3-29 0:00: ER No Violations
-132748169 2011-12-9 0:00: ER No Violations 0.30
-1366115783 2008-3-25 0:00: ER No Violations
-1369577432 2020-8-11 0:00: ER No Violations 0.50
-137691116 2019-3-15 0:00: ER No Violations 1.50
-1444371737 2008-1-16 0:00: ER No Violations
-1452589338 2020-5-4 0:00:0 ER No Violations 1.50
-1458564666 2003-5-15 0:00: ER No Violations
-1459503753 2005-9-14 0:00: ER No Violations
-1501878211 2019-10-21 0:00 ER No Violations 1.50
-1540842109 2007-5-31 0:00: ER No Violations
-1562307453 2010-12-30 0:00 ER No Violations
-1573270120 2004-10-6 0:00: PL No Violations
-1628602701 2019-7-9 0:00:0 ER No Violations 0.50
-1665932623 2018-11-9 0:00: ER No Violations 3.00
-1706022989 2019-9-17 0:00: ER No Violations 1.30
-1774209892 2014-2-13 0:00: ER No Violations 2.50
-1817249623 2005-4-28 0:00: ER No Violations
-1866329080 2018-9-4 0:00:0 ER No Violations 0.40
-1933072027 2019-4-11 0:00: ER No Violations 0.40
-2028735154 2012-12-28 0:00 ER No Violations 0.10
-2047601545 2010-9-13 0:00: ER No Violations 1.00
-2113236852 2008-7-23 0:00: ER No Violations
-241433957 2019-4-23 0:00: ER No Violations 0.50
-266730795 2009-8-17 0:00: ER No Violations
-287542857 2016-1-22 0:00: ER No Violations 2.00
-311829852 2020-1-22 0:00: ER No Violations 1.00
-34534164 2004-8-3 0:00:0 SW No Violations
-429293492 2019-1-4 0:00:0 ER No Violations 1.20
-497535578 2007-4-4 0:00:0 ER No Violations
-51468640 2016-3-28 0:00: ER No Violations 1.00
-521004241 2010-3-9 0:00:0 ER No Violations
-619310033 2006-1-24 0:00: ER No Violations
-623227517 2003-2-6 0:00:0 ER No Violations
-64064997 2004-10-29 0:00 SW No Violations
-733959837 2008-6-13 0:00: ER No Violations
-887069726 2005-2-9 0:00:0 SW No Violations
-938516133 2003-10-9 0:00: ER No Violations
-991929520 2003-3-27 0:00: ER No Violations
001269i462 2001-10-30 Enhanced Recovery Project No Violations No violations at this time.
0030422022 2011-08-02 Enhanced Recovery Project No Violations Good identification. Injection line was shut off due to a line leak at the pump house.
0034534164 2004-08-03 Salt Water Injection Well No Violations No violation
0051468640 2016-03-28 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy.
0064064997 2004-10-29 Salt Water Injection Well No Violations Within limits
0073139744 2013-09-05 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the wellhead.
0117884162 2004-01-28 Salt Water Injection Well No Violations
0122252999 2014-06-20 Enhanced Recovery Project No Violations Inspected injection pressure, annulus pressure and walked the pipe line right of way. Good identification at the well.
01269i1272 2002-08-06 Enhanced Recovery Project No Violations No violations.
0132748169 2011-12-09 Enhanced Recovery Project No Violations Accompanied Jon Scott for ERP training. Site clean, not exceeding max injection.
0137691116 2019-03-15 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection line valve at the well site is open. The injection tubing master valve is open. The injection line valve at the pump house is closed. Identification posted. The injection line test has not been scheduled. The contaminated material has not been removed.
0213555355 2017-05-18 Enhanced Recovery Project No Violations Install two different collars on the tubing. Install a new Parmaco packer with shear pin. Set packer at 701 ft. Pulled 6000lbs over string weight. Tested annulus at 360 psi. At 5 minutes 355 psi. At 15 minutes 350 psi.
0241433957 2019-04-23 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. Inspected the injection pressure, annulus pressure, containment dike, tanks, and unloading pad. Identification posted. Accompanied by UIC Supervisor and UIC Geologist. The injection tubing valve is open, the injection line valve at well site is open, the injection line valve at the pump house is closed. Field tested the line leak site with High Range quantab, results were 6.8 on strip which is 2374 ppm Cl.
0249330952 2017-07-18 Enhanced Recovery Project No Violations Well was identified correctly and pressures were taken.
0266730795 2009-08-17 Enhanced Recovery Project No Violations Good identification. No violations observed during inspection.
0287542857 2016-01-22 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Identification posted at the well.
0334154471 2004-05-20 Salt Water Injection Well No Violations Within allowable limits.
0343066377 2006-08-15 Enhanced Recovery Project No Violations Within limits
0429293492 2019-01-04 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection line valve in the facility pump house is closed. The injection line valve and master valve on the injection tubing are open. Identification is posted. The containment dike is free of fluids. I asked Mike Carr when are they are going to test the injection line. Mike told me he has not been directed to test the injection line. I asked about when the contaminated material is going to be removed and was not given an answer.
0458991467 2005-11-10 Enhanced Recovery Project No Violations Ok
0466174219 2013-01-07 Surface Facility Construction No Violations Concrete dike pad has been poured. Concrete block and mortar is on site. Extended concrete apron to unloading pad.
0497535578 2007-04-04 Enhanced Recovery Project No Violations No problems, Jim Ross has grated the lease roads.
0521004241 2010-03-09 Enhanced Recovery Project No Violations Good identification. No violations during inspection.
0530677655 2018-03-19 Salt Water Injection Well No Violations I was on location today to check the pressures of this salt water injection well. The annulus pressure was 70 psi, the injection tubing pressure was 85 psi. No violations were noted during my inspection.
0587440200 2007-09-25 Enhanced Recovery Project No Violations No violations at this time.
0619310033 2006-01-24 Enhanced Recovery Project No Violations Pressures below maximum allowable; pressure on the annulus.
0623227517 2003-02-06 Enhanced Recovery Project No Violations No violations at the time of inspection.
0660037857 2012-10-03 Enhanced Recovery Project No Violations Inspected injection pressure and annulus pressure. Previous company (Exco North Coast) identification on wellhead.
0701099772 2006-11-21 Enhanced Recovery Project Violations Noted Exceded Maximum Injection pressure
0733959837 2008-06-13 Enhanced Recovery Project No Violations No violations at this time.
0738177136 2009-05-12 Enhanced Recovery Project No Violations Good id. No violations were observed at time of inspection.
0857709900 2004-03-04 Salt Water Injection Well No Violations Within the specified range.
0887069726 2005-02-09 Salt Water Injection Well No Violations Within limits.
0938516133 2003-10-09 Enhanced Recovery Project No Violations No violations at the time of inspection.
0991929520 2003-03-27 Enhanced Recovery Project No Violations No violations at the time of inspection.
1031290594 2013-10-21 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the well head.
1037346802 2014-11-20 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification at well site.
1042707540 2013-01-09 Enhanced Recovery Project No Violations Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Accompanied by Morgan Button MRI 2.
1110659926 2008-09-18 Enhanced Recovery Project No Violations Good id. No violations at this time.
1129395194 2014-08-21 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, walked the injection line, checked the injection pressure and annulus pressure. Good identification at wellhead.
1193483014 2009-02-18 Enhanced Recovery Project No Violations Good id. No violations observed during inspection.
122252999 2014-6-20 0:00: ER No Violations 0.70
1240410997 2013-03-15 Enhanced Recovery Project No Violations Inspected injection pressure and annulus pressure. Good identification at wellhead.
1262327603 2016-11-08 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, unloading pad, injection pumps, injection pressure and annulus pressure. Identification posted at the well. The containment dike is free of fluids.
1264634974 2010-06-07 Enhanced Recovery Project No Violations Well id for Exco-North Coast, Needs to have Enervest information and contact phone numbers. I have talked to Jim Ross (Enervest contractor) about this needing to be changed as soon as possible.
1269i1272 2002-8-6 0:00:0 ER No Violations
1269i462 2001-10-30 0:00 ER No Violations
1301961398 2011-03-17 Enhanced Recovery Project No Violations No violations at this time.
1324936516 2006-03-29 Enhanced Recovery Project No Violations Within limits.
1356717770 2012-12-27 Administrative Inspection No Violations Contacted operator of the Greasy Ridge Field, Jim Ross. Well identification sign has been placed at the wellhead.
1366115783 2008-03-25 Enhanced Recovery Project No Violations No violations were observed. The new pressure regulator is working well.
1399041582 2014-05-02 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure, Unloading pad, containment dike, tanks, and pump house. Good identification at the well.
1405704765 2014-07-18 Enhanced Recovery Project No Violations Inspected the annulus pressure, injection pressure, containment dike, tanks, and unloading pad. Good identification at the well.
1422904936 2015-02-02 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Good identification at well site.
1423137295 2012-04-05 Enhanced Recovery Project Violations Noted Identification needs updated. Lists Exco North Coast as owner. Talked to Jim Ross and he is going to update the Identification.
1428353343 2015-04-06 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Walked injection line to well. Identification posted at the well.
1428920980 2013-05-02 Enhanced Recovery Project No Violations Inspected the injection pressure, annulus pressure, pump house and containment dike.
1438921106 2018-05-24 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pumps, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
1444220968 2015-10-05 Enhanced Recovery Project No Violations Inspected the injection pressure and annulus pressure. Identification posted at well.
1444371737 2008-01-16 Enhanced Recovery Project No Violations Pressure regulators made by Jordan Valves have been installed and are working great. The valves have a max. back pressure of 400psi, and a max. working pressure of 600psi. They are being set slightly below max. injection pressures.
1458564666 2003-05-15 Enhanced Recovery Project No Violations No violations at the time of inspection.
1459503753 2005-09-14 Enhanced Recovery Project No Violations OK.
1465300640 2016-06-06 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The injection pump is currently being rebuilt onsite. The containment dike is free of fluids.
1471627291 2016-08-19 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well.
1484833320 2017-01-18 Enhanced Recovery Project No Violations Inspected the containment dike, tanks, injection pump, injection pressure, annulus pressure and unloading pad. Identification posted.
1494956068 2017-05-15 Enhanced Recovery Project No Violations Francis Brothers service rig attempted to release the packer and replace the top joint of injection tubing. The tubing was cut off at the well head slips and a tubing spear was inserted into the tubing. The packer was not able to be released and the tubing was threaded off of the packer collar. The top joint measured 29.2 feet. The replacement top joint measured 29.6 feet. The tubing was threaded back onto the packer collar and the annulus was tested at 300 psi. 1st test lost 50 psi in 3 minutes. The 2nd test lost 50 psi in 3 minutes. The 3rd test lost 40 psi in 2 minutes. Additional attempts were made to release the packer. A final attempt to pull the packer resulted in the packer separating down hole. The bottom portion of the packer (set at 699 feet) was not retrieved from the 4.5 inch casing. The upper portion of the packer appears to be a Parmaco packer. The wellhead was shut in with a collar locked joint of tubing and a valve. The packer job is being rescheduled due to the need to replace the packer.
1495131458 2017-05-17 Enhanced Recovery Project No Violations Francis Brothers service rig on well. Install rebuilt Parmaco packer and used 2 3/8 inch tubing. Set packer at 673.3 ft. With 5000 lbs. over string weight. Was unable to keep pressure on the annulus. Pulled 8000 lbs. over string weight and tested. Unable to test the annulus. Released the packer and installed a 8.2 ft. sub joint of tubing. Set packer at 681.5 ft. with 10000 lbs. over string weight. Unable to test the annulus. Released the packer and extracted the tubing and packer. Test the tubing joints and packer at the surface. The packer failed to hold test and two tubing collars were egg shaped.
1540842109 2007-05-31 Enhanced Recovery Project No Violations Pressures are good. Old filters were left on the site. Jim Ross is cleaning the old filters up and putting them in a dumpster.
1544641997 2018-12-10 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection line valve at the pump house is closed. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted at the well site. The containment dike is free of fluids. The injection line test has not been scheduled. The contaminated soil has not been removed from the site.
1550601458 2019-02-15 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. Inspected the injection pressure and annulus pressure. The injection line valve at the pump house is shut off. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted. The injection line has not been tested. The contaminated soil has not been removed.
1559148309 2019-5-28 0:00: ER No Violations 0.20
1562307453 2010-12-30 Enhanced Recovery Project No Violations Identification needs refreshed, has previous owner Exco- North Coast and wrong contact phone number. I talked to Jim Ross and he has the blank Ids and is in the process of filling in the information for the entire ERP field.
1573270120 2004-10-06 Preliminary Restoration No Violations Passed
1585573912 2020-3-26 0:00: ER No Violations 2.50
1585922410 2020-4-1 0:00:0 ER No Violations 1.20
1665932623 2018-11-09 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection line leak location has been recently excavated and the injection line valve in the pump house is open. The injection line valve and the injection tubing master valve are open. The injection line has not been tested by the UIC Inspector. The contaminated soil has not been removed from the site.
176679966 2019-12-20 0:00 ER No Violations 0.50
1774209892 2014-02-13 Enhanced Recovery Project No Violations Bimonthly inspection of ERP field injection wells performed by me and Jon Scott. There are no noticeable leaks in plumbing at wellhead. Identification sign and wellhead in good shape.
1817249623 2005-04-28 Enhanced Recovery Project No Violations Passed
1843853010 2015-06-23 Salt Water Injection Well No Violations No noted violations.
1866329080 2018-09-04 Enhanced Recovery Project No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well. The containment dike is free of fluids.
1894575273 2007-02-23 Enhanced Recovery Project No Violations Passed mini test. No problems at this time.
1912893410 2019-6-12 0:00: ER No Violations 0.50
1927161476 2013-12-11 Surface Facility Construction No Violations Inspected the changes that have been made to the pump house injection line manifolds and the change over to a different injection pump. Inspected the unloading pad, containment dike and tanks.
1933072027 2019-04-11 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection tubing valve is open. The injection line valve at the well site is open. The injection line valve at the pump house is closed.
1955006326 2017-06-21 Salt Water Injection Well No Violations Salt water injection well inspection. The annulus pressure was 1 PSI, the tubing pressure was 79 psi. Legible identification was posted. No violations were noted.
1956699568 2009-11-17 Enhanced Recovery Project No Violations Good Identification. No violations observed during inspection.
1970143535 2018-11-19 Enhanced Recovery Project No Violations Compliance Notice # 2076209844 follow up inspection. The injection line valve in the pump house is closed. The injection line valve at the well head and injection tubing master valve are open. Collected a soil sample from the injection line leak site. ODNR DOGRM Geologist on site.
2028735154 2012-12-28 Enhanced Recovery Project No Violations Inspected this injection well while conducting UIC inspection of injection wells. The sign was replaced with the appropriate identification well sign.
2047601545 2010-09-13 Enhanced Recovery Project No Violations Brine leak on 1 hammer union. Leak is between the filter housing and the flow meter. Steady drip has stained the identification and has splashed on ground in a three foot diameter.
2047792151 2012-10-03 Enhanced Recovery Project No Violations Inspected wells with Jon Scott. Measured Injection and Annulus pressure for wells in this field. Well identification was incorrect. Well must have identification(1509:9-9-05(A)(10): Well owner, lease name, well number, permit number, county, and emergency telephone number. Need to provide present owner and current phone numbers. Talked to Jim Ross in our field meeting the following day, 10/04/2012, and issued a verbal complaint to him on this violation.
2076209844 2018-10-22 Enhanced Recovery Project Violations Noted Inspected the injection pressure and annulus pressure. The injection tubing is on vacuum. While inspecting the surface facility the injection line valve to the well was shut off. Out side the injection facility a scald area 12 feet by 22 feet was observed. A high range Quantab was used in a pool of fluid with in the scald area next to a line marker. The high range Quantab was 8.2 on the strip which is 4621 ppm Cl. The injection line must be repaired or replaced. The injection line must be tested and witnessed by UIC Inspector prior to operation. Submit a plan to the Division of Oil and Gas UIC Section regarding the proposed remediation of the Brine contaminated soil.
2078985094 2013-07-15 Enhanced Recovery Project No Violations Inspected injection pressure, annulus pressure, Containment dike, tanks, pump, and unloading pad. Good identification. A new flow meter has been installed at the well head. Flow meter records in gallons.
2113236852 2008-07-23 Enhanced Recovery Project No Violations Good Identification. No violations at this time.
213555355 2017-5-18 0:00: ER No Violations 5.00
2145126506 2013-01-09 Enhanced Recovery Project No Violations Accompanied Jon Scott to this injection well to perform bimonthly inspection and measure its annulus pressure and actual injection pressure.
249330952 2017-7-18 0:00: ER No Violations 0.50
30422022 2011-8-2 0:00:0 ER No Violations
334154471 2004-5-20 0:00: SW No Violations
343066377 2006-8-15 0:00: ER No Violations
458991467 2005-11-10 0:00 ER No Violations
466174219 2013-1-7 0:00:0 SC No Violations 2.50
530677655 2018-3-19 0:00: SW No Violations 0.40
587440200 2007-9-25 0:00: ER No Violations
660037857 2012-10-3 0:00: ER No Violations 0.50
701099772 2006-11-21 0:00 ER No Violations
73139744 2013-9-5 0:00:0 ER No Violations 0.50
738177136 2009-5-12 0:00: ER No Violations
830445799 2020-7-14 0:00: ER No Violations 0.50
857709900 2004-3-4 0:00:0 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0701099772 US-OH-127918 2006-11-27 Exceeding maximum allowable injection pressure
1423137295 US-OH-112313 2012-04-19 Insufficient/No identification
2076209844 US-OH-121185 2018-10-23 9-5-06 Pollution/Contamination

For data sources see[9]