If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-087-20461 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.62,"lon":-82.44,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Lawrence | |
| Municipality: Mason Township | |
| Operator Name: PILLAR ENERGY LLC | |
| Well Pad ID: | |
| Farm/Lease Name: MAYER J | |
| License Status: Active Injection | |
| License Date: 1997-06-10 | |
| Spud Date: 1995-11-29 | |
| Spud Drilling Contractor: CENTURY WELL SERVICES,INC | |
| Final Drill Date: 1995-12-02 | |
| Well Total Depth: 875.00 ft | |
| Configuration: Vertical | |
| Latitude: 38.620000 | |
| Longitude: -82.440000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| Oil and Gas | 1990-08-15 | Issued Date 8/15/90 Expired Date 8/15/91 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00000 Proposed Drill Depth 00000 |
| CO | 1995-11-02 | 1089 MITCHELL ENERGY CORP GeoDate 11/2/95 |
| Oil and Gas | 1995-11-02 | Issued Date 11/2/95 Expired Date 11/1/96 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth 00875 Proposed Drill Depth 00875 |
| Original Spud | 1995-11-30 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| Completed | 1995-12-02 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| Reached Total Depth | 1995-12-02 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| CO | 1996-02-06 | 1089 MITCHELL ENERGY CORP GeoDate 8/15/90 |
| Construction Permit Expires | 1996-11-01 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| CO | 1997-06-10 | 1089 MITCHELL ENERGY CORP GeoDt 6/10/97 |
| Enhanced Recovery | 1997-06-10 | Issued Date 6/10/97 Expired Date 6/10/98 Acres 0001000 Tool Type RTF Proposed Formation COW RUN Proposed Depth Proposed Drill Depth |
| Annulus Pressure Monitoring Approved | 1997-09-18 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| First Injection | 1997-09-18 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| Completion Report Received | 1997-10-14 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| Last Compliance Report | 2000-03-02 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
| Change of Owner | 2004-05-25 | Operator changed from 1089, MITCHELL ENERGY CORP to 3793, ENERGY SEARCH INC.
THIS WELL WAS ON THE CHANGE OF OWNER FORM FROM MITCHELL TO ENERGY SEARCH BUT WAS MISSED. LINDA SLATER BROUGHT IT TO MY ATTENTION AND I TRANSFERRED IT TODAY. MM |
| Change of Owner | 2008-12-10 | Operator changed from 3793, ENERGY SEARCH INC to 1388, EXCO - NORTH COAST ENERGY INC |
| Change of Owner | 2009-12-14 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
| Change of Owner | 2016-02-24 | Operator changed from 7578, ENERVEST OPERATING LLC to 9619, PILLAR ENERGY LLC |
| Record Last Modified | 2017-02-15 | Converted to SWIW 9-18-97 RI/RL 11-4-96, CONVERT 6-14-97 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2000-03-02 | 764 | 785 | 1 |
| 764 | 785 | 1 | |
| 764 | 785 | 1 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| H2O | 0 | 226 Bbl | 20100 | FRAC WITH WATER AND SAND |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1995 | MITCHELL ENERGY CORP | 0.00 | 0.00 | 0 |
| 1996 | MITCHELL ENERGY CORP | 0.00 | 1182.00 | 306 |
| 1997 | MITCHELL ENERGY CORP | 0.00 | 0.00 | 307 |
| 1998 | MITCHELL ENERGY CORP | 0.00 | 0.00 | 0 |
| 1999 | ENERGY SEARCH INC | 0.00 | 0.00 | 60 |
| 2000 | ENERGY SEARCH INC | 0.00 | 0.00 | 365 |
| 2001 | ENERGY SEARCH INC | 0.00 | 3388.00 | 365 |
| 2002 | ENERGY SEARCH INC | 0.00 | 31.00 | 365 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1995 | MITCHELL ENERGY CORP | Brine | 0 | 0 |
| 1996 | MITCHELL ENERGY CORP | Brine | 212 | 306 |
| 1997 | MITCHELL ENERGY CORP | Brine | 0 | 307 |
| 1998 | MITCHELL ENERGY CORP | Brine | ||
| 1999 | MITCHELL ENERGY CORP | Brine | ||
| 2000 | ENERGY SEARCH INC | Brine | 365 | |
| 2001 | ENERGY SEARCH INC | Brine | 0 | 365 |
| 2002 | ENERGY SEARCH INC | Brine | 365 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1031290594 | 2013-10-21 0:00 | ER | No Violations | 0.50 |
| -1079519748 | 2019-11-29 0:00 | ER | No Violations | 1.00 |
| -1110659926 | 2008-9-18 0:00: | ER | No Violations | |
| -117884162 | 2004-1-28 0:00: | SW | No Violations | |
| -1262327603 | 2016-11-8 0:00: | ER | No Violations | 1.00 |
| -1264634974 | 2010-6-7 0:00:0 | ER | No Violations | 1.00 |
| -1324936516 | 2006-3-29 0:00: | ER | No Violations | |
| -132748169 | 2011-12-9 0:00: | ER | No Violations | 0.30 |
| -1366115783 | 2008-3-25 0:00: | ER | No Violations | |
| -1369577432 | 2020-8-11 0:00: | ER | No Violations | 0.50 |
| -137691116 | 2019-3-15 0:00: | ER | No Violations | 1.50 |
| -1444371737 | 2008-1-16 0:00: | ER | No Violations | |
| -1452589338 | 2020-5-4 0:00:0 | ER | No Violations | 1.50 |
| -1458564666 | 2003-5-15 0:00: | ER | No Violations | |
| -1459503753 | 2005-9-14 0:00: | ER | No Violations | |
| -1501878211 | 2019-10-21 0:00 | ER | No Violations | 1.50 |
| -1540842109 | 2007-5-31 0:00: | ER | No Violations | |
| -1562307453 | 2010-12-30 0:00 | ER | No Violations | |
| -1573270120 | 2004-10-6 0:00: | PL | No Violations | |
| -1628602701 | 2019-7-9 0:00:0 | ER | No Violations | 0.50 |
| -1665932623 | 2018-11-9 0:00: | ER | No Violations | 3.00 |
| -1706022989 | 2019-9-17 0:00: | ER | No Violations | 1.30 |
| -1774209892 | 2014-2-13 0:00: | ER | No Violations | 2.50 |
| -1817249623 | 2005-4-28 0:00: | ER | No Violations | |
| -1866329080 | 2018-9-4 0:00:0 | ER | No Violations | 0.40 |
| -1933072027 | 2019-4-11 0:00: | ER | No Violations | 0.40 |
| -2028735154 | 2012-12-28 0:00 | ER | No Violations | 0.10 |
| -2047601545 | 2010-9-13 0:00: | ER | No Violations | 1.00 |
| -2113236852 | 2008-7-23 0:00: | ER | No Violations | |
| -241433957 | 2019-4-23 0:00: | ER | No Violations | 0.50 |
| -266730795 | 2009-8-17 0:00: | ER | No Violations | |
| -287542857 | 2016-1-22 0:00: | ER | No Violations | 2.00 |
| -311829852 | 2020-1-22 0:00: | ER | No Violations | 1.00 |
| -34534164 | 2004-8-3 0:00:0 | SW | No Violations | |
| -429293492 | 2019-1-4 0:00:0 | ER | No Violations | 1.20 |
| -497535578 | 2007-4-4 0:00:0 | ER | No Violations | |
| -51468640 | 2016-3-28 0:00: | ER | No Violations | 1.00 |
| -521004241 | 2010-3-9 0:00:0 | ER | No Violations | |
| -619310033 | 2006-1-24 0:00: | ER | No Violations | |
| -623227517 | 2003-2-6 0:00:0 | ER | No Violations | |
| -64064997 | 2004-10-29 0:00 | SW | No Violations | |
| -733959837 | 2008-6-13 0:00: | ER | No Violations | |
| -887069726 | 2005-2-9 0:00:0 | SW | No Violations | |
| -938516133 | 2003-10-9 0:00: | ER | No Violations | |
| -991929520 | 2003-3-27 0:00: | ER | No Violations | |
| 001269i462 | 2001-10-30 | Enhanced Recovery Project | No Violations | No violations at this time. |
| 0030422022 | 2011-08-02 | Enhanced Recovery Project | No Violations | Good identification. Injection line was shut off due to a line leak at the pump house. |
| 0034534164 | 2004-08-03 | Salt Water Injection Well | No Violations | No violation |
| 0051468640 | 2016-03-28 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification has not been changed from Enervest to Pillar Energy. |
| 0064064997 | 2004-10-29 | Salt Water Injection Well | No Violations | Within limits |
| 0073139744 | 2013-09-05 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the wellhead. |
| 0117884162 | 2004-01-28 | Salt Water Injection Well | No Violations | |
| 0122252999 | 2014-06-20 | Enhanced Recovery Project | No Violations | Inspected injection pressure, annulus pressure and walked the pipe line right of way. Good identification at the well. |
| 01269i1272 | 2002-08-06 | Enhanced Recovery Project | No Violations | No violations. |
| 0132748169 | 2011-12-09 | Enhanced Recovery Project | No Violations | Accompanied Jon Scott for ERP training. Site clean, not exceeding max injection. |
| 0137691116 | 2019-03-15 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection line valve at the well site is open. The injection tubing master valve is open. The injection line valve at the pump house is closed. Identification posted. The injection line test has not been scheduled. The contaminated material has not been removed. |
| 0213555355 | 2017-05-18 | Enhanced Recovery Project | No Violations | Install two different collars on the tubing. Install a new Parmaco packer with shear pin. Set packer at 701 ft. Pulled 6000lbs over string weight. Tested annulus at 360 psi. At 5 minutes 355 psi. At 15 minutes 350 psi. |
| 0241433957 | 2019-04-23 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. Inspected the injection pressure, annulus pressure, containment dike, tanks, and unloading pad. Identification posted. Accompanied by UIC Supervisor and UIC Geologist. The injection tubing valve is open, the injection line valve at well site is open, the injection line valve at the pump house is closed. Field tested the line leak site with High Range quantab, results were 6.8 on strip which is 2374 ppm Cl. |
| 0249330952 | 2017-07-18 | Enhanced Recovery Project | No Violations | Well was identified correctly and pressures were taken. |
| 0266730795 | 2009-08-17 | Enhanced Recovery Project | No Violations | Good identification. No violations observed during inspection. |
| 0287542857 | 2016-01-22 | Enhanced Recovery Project | No Violations | Inspected the injection pressure and annulus pressure. Identification posted at the well. |
| 0334154471 | 2004-05-20 | Salt Water Injection Well | No Violations | Within allowable limits. |
| 0343066377 | 2006-08-15 | Enhanced Recovery Project | No Violations | Within limits |
| 0429293492 | 2019-01-04 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection line valve in the facility pump house is closed. The injection line valve and master valve on the injection tubing are open. Identification is posted. The containment dike is free of fluids. I asked Mike Carr when are they are going to test the injection line. Mike told me he has not been directed to test the injection line. I asked about when the contaminated material is going to be removed and was not given an answer. |
| 0458991467 | 2005-11-10 | Enhanced Recovery Project | No Violations | Ok |
| 0466174219 | 2013-01-07 | Surface Facility Construction | No Violations | Concrete dike pad has been poured. Concrete block and mortar is on site. Extended concrete apron to unloading pad. |
| 0497535578 | 2007-04-04 | Enhanced Recovery Project | No Violations | No problems, Jim Ross has grated the lease roads. |
| 0521004241 | 2010-03-09 | Enhanced Recovery Project | No Violations | Good identification. No violations during inspection. |
| 0530677655 | 2018-03-19 | Salt Water Injection Well | No Violations | I was on location today to check the pressures of this salt water injection well. The annulus pressure was 70 psi, the injection tubing pressure was 85 psi. No violations were noted during my inspection. |
| 0587440200 | 2007-09-25 | Enhanced Recovery Project | No Violations | No violations at this time. |
| 0619310033 | 2006-01-24 | Enhanced Recovery Project | No Violations | Pressures below maximum allowable; pressure on the annulus. |
| 0623227517 | 2003-02-06 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
| 0660037857 | 2012-10-03 | Enhanced Recovery Project | No Violations | Inspected injection pressure and annulus pressure. Previous company (Exco North Coast) identification on wellhead. |
| 0701099772 | 2006-11-21 | Enhanced Recovery Project | Violations Noted | Exceded Maximum Injection pressure |
| 0733959837 | 2008-06-13 | Enhanced Recovery Project | No Violations | No violations at this time. |
| 0738177136 | 2009-05-12 | Enhanced Recovery Project | No Violations | Good id. No violations were observed at time of inspection. |
| 0857709900 | 2004-03-04 | Salt Water Injection Well | No Violations | Within the specified range. |
| 0887069726 | 2005-02-09 | Salt Water Injection Well | No Violations | Within limits. |
| 0938516133 | 2003-10-09 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
| 0991929520 | 2003-03-27 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
| 1031290594 | 2013-10-21 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Good identification at the well head. |
| 1037346802 | 2014-11-20 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Good identification at well site. |
| 1042707540 | 2013-01-09 | Enhanced Recovery Project | No Violations | Inspected enhanced recovery well injection tubing pressure and annulus pressure. Good identification at well head. Accompanied by Morgan Button MRI 2. |
| 1110659926 | 2008-09-18 | Enhanced Recovery Project | No Violations | Good id. No violations at this time. |
| 1129395194 | 2014-08-21 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pump, walked the injection line, checked the injection pressure and annulus pressure. Good identification at wellhead. |
| 1193483014 | 2009-02-18 | Enhanced Recovery Project | No Violations | Good id. No violations observed during inspection. |
| 122252999 | 2014-6-20 0:00: | ER | No Violations | 0.70 |
| 1240410997 | 2013-03-15 | Enhanced Recovery Project | No Violations | Inspected injection pressure and annulus pressure. Good identification at wellhead. |
| 1262327603 | 2016-11-08 | Enhanced Recovery Project | No Violations | Inspected the containment dike, tanks, unloading pad, injection pumps, injection pressure and annulus pressure. Identification posted at the well. The containment dike is free of fluids. |
| 1264634974 | 2010-06-07 | Enhanced Recovery Project | No Violations | Well id for Exco-North Coast, Needs to have Enervest information and contact phone numbers. I have talked to Jim Ross (Enervest contractor) about this needing to be changed as soon as possible. |
| 1269i1272 | 2002-8-6 0:00:0 | ER | No Violations | |
| 1269i462 | 2001-10-30 0:00 | ER | No Violations | |
| 1301961398 | 2011-03-17 | Enhanced Recovery Project | No Violations | No violations at this time. |
| 1324936516 | 2006-03-29 | Enhanced Recovery Project | No Violations | Within limits. |
| 1356717770 | 2012-12-27 | Administrative Inspection | No Violations | Contacted operator of the Greasy Ridge Field, Jim Ross. Well identification sign has been placed at the wellhead. |
| 1366115783 | 2008-03-25 | Enhanced Recovery Project | No Violations | No violations were observed. The new pressure regulator is working well. |
| 1399041582 | 2014-05-02 | Enhanced Recovery Project | No Violations | Inspected the injection pressure, annulus pressure, Unloading pad, containment dike, tanks, and pump house. Good identification at the well. |
| 1405704765 | 2014-07-18 | Enhanced Recovery Project | No Violations | Inspected the annulus pressure, injection pressure, containment dike, tanks, and unloading pad. Good identification at the well. |
| 1422904936 | 2015-02-02 | Enhanced Recovery Project | No Violations | Inspected the injection pressure and annulus pressure. Good identification at well site. |
| 1423137295 | 2012-04-05 | Enhanced Recovery Project | Violations Noted | Identification needs updated. Lists Exco North Coast as owner. Talked to Jim Ross and he is going to update the Identification. |
| 1428353343 | 2015-04-06 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Walked injection line to well. Identification posted at the well. |
| 1428920980 | 2013-05-02 | Enhanced Recovery Project | No Violations | Inspected the injection pressure, annulus pressure, pump house and containment dike. |
| 1438921106 | 2018-05-24 | Enhanced Recovery Project | No Violations | Inspected the containment dike, tanks, injection pumps, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
| 1444220968 | 2015-10-05 | Enhanced Recovery Project | No Violations | Inspected the injection pressure and annulus pressure. Identification posted at well. |
| 1444371737 | 2008-01-16 | Enhanced Recovery Project | No Violations | Pressure regulators made by Jordan Valves have been installed and are working great. The valves have a max. back pressure of 400psi, and a max. working pressure of 600psi. They are being set slightly below max. injection pressures. |
| 1458564666 | 2003-05-15 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
| 1459503753 | 2005-09-14 | Enhanced Recovery Project | No Violations | OK. |
| 1465300640 | 2016-06-06 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The injection pump is currently being rebuilt onsite. The containment dike is free of fluids. |
| 1471627291 | 2016-08-19 | Enhanced Recovery Project | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well. |
| 1484833320 | 2017-01-18 | Enhanced Recovery Project | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure, annulus pressure and unloading pad. Identification posted. |
| 1494956068 | 2017-05-15 | Enhanced Recovery Project | No Violations | Francis Brothers service rig attempted to release the packer and replace the top joint of injection tubing. The tubing was cut off at the well head slips and a tubing spear was inserted into the tubing. The packer was not able to be released and the tubing was threaded off of the packer collar. The top joint measured 29.2 feet. The replacement top joint measured 29.6 feet. The tubing was threaded back onto the packer collar and the annulus was tested at 300 psi. 1st test lost 50 psi in 3 minutes. The 2nd test lost 50 psi in 3 minutes. The 3rd test lost 40 psi in 2 minutes. Additional attempts were made to release the packer. A final attempt to pull the packer resulted in the packer separating down hole. The bottom portion of the packer (set at 699 feet) was not retrieved from the 4.5 inch casing. The upper portion of the packer appears to be a Parmaco packer. The wellhead was shut in with a collar locked joint of tubing and a valve. The packer job is being rescheduled due to the need to replace the packer. |
| 1495131458 | 2017-05-17 | Enhanced Recovery Project | No Violations | Francis Brothers service rig on well. Install rebuilt Parmaco packer and used 2 3/8 inch tubing. Set packer at 673.3 ft. With 5000 lbs. over string weight. Was unable to keep pressure on the annulus. Pulled 8000 lbs. over string weight and tested. Unable to test the annulus. Released the packer and installed a 8.2 ft. sub joint of tubing. Set packer at 681.5 ft. with 10000 lbs. over string weight. Unable to test the annulus. Released the packer and extracted the tubing and packer. Test the tubing joints and packer at the surface. The packer failed to hold test and two tubing collars were egg shaped. |
| 1540842109 | 2007-05-31 | Enhanced Recovery Project | No Violations | Pressures are good. Old filters were left on the site. Jim Ross is cleaning the old filters up and putting them in a dumpster. |
| 1544641997 | 2018-12-10 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection line valve at the pump house is closed. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted at the well site. The containment dike is free of fluids. The injection line test has not been scheduled. The contaminated soil has not been removed from the site. |
| 1550601458 | 2019-02-15 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. Inspected the injection pressure and annulus pressure. The injection line valve at the pump house is shut off. The injection line valve at the well site is open. The injection tubing master valve is open. Identification is posted. The injection line has not been tested. The contaminated soil has not been removed. |
| 1559148309 | 2019-5-28 0:00: | ER | No Violations | 0.20 |
| 1562307453 | 2010-12-30 | Enhanced Recovery Project | No Violations | Identification needs refreshed, has previous owner Exco- North Coast and wrong contact phone number. I talked to Jim Ross and he has the blank Ids and is in the process of filling in the information for the entire ERP field. |
| 1573270120 | 2004-10-06 | Preliminary Restoration | No Violations | Passed |
| 1585573912 | 2020-3-26 0:00: | ER | No Violations | 2.50 |
| 1585922410 | 2020-4-1 0:00:0 | ER | No Violations | 1.20 |
| 1665932623 | 2018-11-09 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection line leak location has been recently excavated and the injection line valve in the pump house is open. The injection line valve and the injection tubing master valve are open. The injection line has not been tested by the UIC Inspector. The contaminated soil has not been removed from the site. |
| 176679966 | 2019-12-20 0:00 | ER | No Violations | 0.50 |
| 1774209892 | 2014-02-13 | Enhanced Recovery Project | No Violations | Bimonthly inspection of ERP field injection wells performed by me and Jon Scott. There are no noticeable leaks in plumbing at wellhead. Identification sign and wellhead in good shape. |
| 1817249623 | 2005-04-28 | Enhanced Recovery Project | No Violations | Passed |
| 1843853010 | 2015-06-23 | Salt Water Injection Well | No Violations | No noted violations. |
| 1866329080 | 2018-09-04 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well. The containment dike is free of fluids. |
| 1894575273 | 2007-02-23 | Enhanced Recovery Project | No Violations | Passed mini test. No problems at this time. |
| 1912893410 | 2019-6-12 0:00: | ER | No Violations | 0.50 |
| 1927161476 | 2013-12-11 | Surface Facility Construction | No Violations | Inspected the changes that have been made to the pump house injection line manifolds and the change over to a different injection pump. Inspected the unloading pad, containment dike and tanks. |
| 1933072027 | 2019-04-11 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection tubing valve is open. The injection line valve at the well site is open. The injection line valve at the pump house is closed. |
| 1955006326 | 2017-06-21 | Salt Water Injection Well | No Violations | Salt water injection well inspection. The annulus pressure was 1 PSI, the tubing pressure was 79 psi. Legible identification was posted. No violations were noted. |
| 1956699568 | 2009-11-17 | Enhanced Recovery Project | No Violations | Good Identification. No violations observed during inspection. |
| 1970143535 | 2018-11-19 | Enhanced Recovery Project | No Violations | Compliance Notice # 2076209844 follow up inspection. The injection line valve in the pump house is closed. The injection line valve at the well head and injection tubing master valve are open. Collected a soil sample from the injection line leak site. ODNR DOGRM Geologist on site. |
| 2028735154 | 2012-12-28 | Enhanced Recovery Project | No Violations | Inspected this injection well while conducting UIC inspection of injection wells. The sign was replaced with the appropriate identification well sign. |
| 2047601545 | 2010-09-13 | Enhanced Recovery Project | No Violations | Brine leak on 1 hammer union. Leak is between the filter housing and the flow meter. Steady drip has stained the identification and has splashed on ground in a three foot diameter. |
| 2047792151 | 2012-10-03 | Enhanced Recovery Project | No Violations | Inspected wells with Jon Scott. Measured Injection and Annulus pressure for wells in this field. Well identification was incorrect. Well must have identification(1509:9-9-05(A)(10): Well owner, lease name, well number, permit number, county, and emergency telephone number. Need to provide present owner and current phone numbers. Talked to Jim Ross in our field meeting the following day, 10/04/2012, and issued a verbal complaint to him on this violation. |
| 2076209844 | 2018-10-22 | Enhanced Recovery Project | Violations Noted | Inspected the injection pressure and annulus pressure. The injection tubing is on vacuum. While inspecting the surface facility the injection line valve to the well was shut off. Out side the injection facility a scald area 12 feet by 22 feet was observed. A high range Quantab was used in a pool of fluid with in the scald area next to a line marker. The high range Quantab was 8.2 on the strip which is 4621 ppm Cl. The injection line must be repaired or replaced. The injection line must be tested and witnessed by UIC Inspector prior to operation. Submit a plan to the Division of Oil and Gas UIC Section regarding the proposed remediation of the Brine contaminated soil. |
| 2078985094 | 2013-07-15 | Enhanced Recovery Project | No Violations | Inspected injection pressure, annulus pressure, Containment dike, tanks, pump, and unloading pad. Good identification. A new flow meter has been installed at the well head. Flow meter records in gallons. |
| 2113236852 | 2008-07-23 | Enhanced Recovery Project | No Violations | Good Identification. No violations at this time. |
| 213555355 | 2017-5-18 0:00: | ER | No Violations | 5.00 |
| 2145126506 | 2013-01-09 | Enhanced Recovery Project | No Violations | Accompanied Jon Scott to this injection well to perform bimonthly inspection and measure its annulus pressure and actual injection pressure. |
| 249330952 | 2017-7-18 0:00: | ER | No Violations | 0.50 |
| 30422022 | 2011-8-2 0:00:0 | ER | No Violations | |
| 334154471 | 2004-5-20 0:00: | SW | No Violations | |
| 343066377 | 2006-8-15 0:00: | ER | No Violations | |
| 458991467 | 2005-11-10 0:00 | ER | No Violations | |
| 466174219 | 2013-1-7 0:00:0 | SC | No Violations | 2.50 |
| 530677655 | 2018-3-19 0:00: | SW | No Violations | 0.40 |
| 587440200 | 2007-9-25 0:00: | ER | No Violations | |
| 660037857 | 2012-10-3 0:00: | ER | No Violations | 0.50 |
| 701099772 | 2006-11-21 0:00 | ER | No Violations | |
| 73139744 | 2013-9-5 0:00:0 | ER | No Violations | 0.50 |
| 738177136 | 2009-5-12 0:00: | ER | No Violations | |
| 830445799 | 2020-7-14 0:00: | ER | No Violations | 0.50 |
| 857709900 | 2004-3-4 0:00:0 | SW | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0701099772 | US-OH-127918 | 2006-11-27 | Exceeding maximum allowable injection pressure | |
| 1423137295 | US-OH-112313 | 2012-04-19 | Insufficient/No identification | |
| 2076209844 | US-OH-121185 | 2018-10-23 | 9-5-06 | Pollution/Contamination |
For data sources see[9]