34-089-21374

Well Details

Well ID: 34-089-21374
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Perry Township
Operator Name: NETHERS GARY L
Well Pad ID:
Farm/Lease Name: TEAGARDEN/LANHAM
License Status: Final Restoration
License Date: 2012-09-11
Spud Date: 1956-03-01
Spud Drilling Contractor:
Final Drill Date: 1956-04-01
Well Total Depth: 754.00 ft
Configuration: Vertical
Latitude: 40.140000
Longitude: -82.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1802-01-01
Original Spud 1956-03-01
Completed 1956-04-01
Reached Total Depth 1956-04-01
CO 1994-06-30 1680 McQUEEN KEVIN L
CO 1994-06-30 4663 INLAND PETROLEUM GeoDate
Change of Owner 2005-11-03 Operator changed from 4663, INLAND PETROLEUM to 2067, NETHERS GARY L
APP 2010-06-23 Proposed Formations:BEREA, Issued Date:6/23/2010, Expired Date:6/23/2011 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
APP 2012-09-11 Proposed Formations:BEREA, Issued Date:9/11/2012, Expired Date:9/11/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2012-09-14
Construction Permit Expires 2014-09-11
Record Last Modified 2016-06-17

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 743 754 0
743 754 0
743 754 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 30 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 INLAND PETROLEUM 0.00 2.00 180
1995 INLAND PETROLEUM 0.00 10.00 200
1996 INLAND PETROLEUM 0.00 16.00 250
1997 INLAND PETROLEUM 0.00 20.00 200
1998 INLAND PETROLEUM 0.00 20.00 250
2000 INLAND PETROLEUM 0.00 18.00 250
2001 INLAND PETROLEUM 0.00 10.00 60
2002 INLAND PETROLEUM 0.00 10.00 40
2003 INLAND PETROLEUM 0.00 2.00 10
2006 NETHERS GARY L 0.00 0.00 365
2007 NETHERS GARY L 0.00 0.00 365
2008 NETHERS GARY L 0.00 5.00 365
2009 NETHERS GARY L 0.00 10.00 270
2011 NETHERS GARY L 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 INLAND PETROLEUM Brine 1 180
1995 INLAND PETROLEUM Brine 1 200
1996 INLAND PETROLEUM Brine 2 250
1997 INLAND PETROLEUM Brine 2 200
1998 INLAND PETROLEUM Brine 2 250
2000 INLAND PETROLEUM Brine 2 250
2001 INLAND PETROLEUM Brine 2 60
2002 INLAND PETROLEUM Brine 2 40
2003 INLAND PETROLEUM Brine 1 10
2006 NETHERS GARY L Brine 0 365
2007 NETHERS GARY L Brine 0 365
2008 NETHERS GARY L Brine 0 365
2009 NETHERS GARY L Brine 2 270
2011 NETHERS GARY L Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1976373522 2016-6-2 0:00:0 FR No Violations
1060570336 2011-06-17 Production Wells No Violations Verified well location with Nathan Nethers prior to plugging and abandonment. A GPS reading was recorded for the wellbore.
1347029007 2012-09-07 Plug / Plug Back No Violations I witnessed plugging operations today. The bottom hole clay plug was washed in to cover the Berea formation. The 7 casing had previously been pulled from this well and 4.5 casing installed inside the 8 drive pipe to serve as a packer. 110 of 4.5 casing was retrieved. The wellbore will be filled with clay to the surface. Mr. Nathan Nethers was instructed to leave the wellbore open for a week to allow clay to settle. The well location was verified prior to plugging and abandonment.
1976373522 2016-06-02 Final Restoration No Violations Inspect location as a final restoration status check. The well has been plugged and location restored. Plastic flow line was removed during inspection. Inspection meets ORC 1509.072 requirements.

For data sources see[9]