X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-089-24400

Well Details

Well ID: 34-089-24400
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Hopewell Township
Operator Name: JHC II LLC
Well Pad ID:
Farm/Lease Name: VOGELMEIER
License Status: Producing
License Date: 1981-12-31
Spud Date: 1982-04-28
Spud Drilling Contractor: MIDLAND DRLG
Final Drill Date: 1982-05-29
Well Total Depth: 3107.00 ft
Configuration: Vertical
Latitude: 40.020000
Longitude: -82.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-12-31 1336 AKRON OIL CORP GeoDate 12/31/81
Oil and Gas 1981-12-31 Issued Date 12/31/81 Expired Date 12/31/82 Acres 0000000 Tool Type Proposed Formation Proposed Depth Proposed Drill Depth
Original Spud 1982-04-28
Completed 1982-05-14
Reached Total Depth 1982-05-29
Construction Permit Expires 1982-12-31
Change of Owner 1984-02-02 Change Owner From 435 HANLEY HARDIN to 1336 AKRON OIL CORPORATION: 2-2-1984
Change of Owner 2003-06-16 Operator changed from 1336, AKRON OIL CORP to 6295, KNOX ENERGY INC.
Change of Owner 2004-09-13 Operator changed from 6295, KNOX ENERGY INC. to 6224, CAMERON JAMES H II
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 35000
ACID 15 250 Gal 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 AKRON OIL CORP 0.00 379.00 0
1985 AKRON OIL CORP 0.00 651.00 0
1986 AKRON OIL CORP 0.00 366.00 365
1987 AKRON OIL CORP 0.00 222.00 180
1988 AKRON OIL CORP 0.00 238.00 275
1989 AKRON OIL CORP 0.00 145.00 365
2003 KNOX ENERGY INC. 0.00 0.00 147
2004 KNOX ENERGY INC. 0.00 194.00 244
2005 JHC II LLC 0.00 143.00 365
2006 JHC II LLC 0.00 146.00 365
2007 JHC II LLC 0.00 110.00 365
2008 JHC II LLC 0.00 115.00 365
2009 JHC II LLC 0.00 76.00 365
2010 JHC II LLC 0.00 74.00 365
2011 JHC II LLC 0.00 37.00 365
2012 JHC II LLC 0.00 97.00 366
2013 JHC II LLC 0.00 49.00 365
2014 JHC II LLC 0.00 107.00 365
2015 JHC II LLC 0.00 36.00 365
2016 JHC II LLC 0.00 55.00 365
2017 JHC II LLC 0.00 104.00 365
2018 JHC II LLC 0.00 50.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 AKRON OIL CORP Brine 100 0
1985 AKRON OIL CORP Brine 200 0
1986 AKRON OIL CORP Brine 250 365
1987 AKRON OIL CORP Brine 150 180
1988 AKRON OIL CORP Brine 220 275
1989 AKRON OIL CORP Brine 120 365
2003 KNOX ENERGY INC. Brine 90 147
2004 JHC II LLC Brine 0 365
2005 JHC II LLC Brine 20 365
2006 JHC II LLC Brine 200 365
2007 JHC II LLC Brine 0 365
2008 JHC II LLC Brine 70 365
2009 JHC II LLC Brine 0 365
2010 JHC II LLC Brine 0 365
2011 JHC II LLC Brine 100 365
2012 JHC II LLC Brine 0 366
2013 JHC II LLC Brine 0 365
2014 JHC II LLC Brine 0 365
2015 JHC II LLC Brine 0 365
2016 JHC II LLC Brine 0 365
2017 JHC II LLC Brine 0 365
2018 JHC II LLC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1860173683 2018-3-26 0:00: PW No Violations 0.50
1039187364 2002-12-06 Production Wells Violations Noted Inspection conducted at the request of Tom Tugend. (E MAIL dated 12/05/02) Inspection revealed One (1) 100 Bbl. storage tank at the end of the lease road. (Photo #1) Two (2) 100 Bbl. storage tanks at the tank battery. Photo #2) (ID posted. Photo #3) There is a flair located between the tank battery and the well. (Photo# 4) There is vegetation growing in the pumping unit. (Photo #5) There are no drive belts from the electric motor to the gearbox on the unit. (Photo #6) The production valves are closed on the well head. (Photo #7) There is a one (1) inch plastic line coming off the wellhead and the valve is open. ( I track this line to a pile of debris at the end of the lease road.
1069283567 2003-11-19 Production Wells Violations Noted Complaint from Anthony about H2S gas escaping from a well that the casing was damaged beyond repair that the owner had to pore concrete around the casing. Inspection revealed the gas is escaping from the 8 5/8 casing and a malfunctioning check valve. I advise Bill Mitten to hook a line up the valve and flair the gas. We are going to meet on site next Wednesday to make sure the hook-up meets requirements.
1070466472 2003-12-03 Production Wells No Violations Follow-up revealed no change in wells status.
1075212657 2004-01-27 Production Wells No Violations Follow-up reviled owner is flaring the gas from the wells annuals. Flair meets requirements. No violations noted this date. WEATHER CONDITIONS: Cloudy 35 degrees and three (3) inches of snow cover.
1860173683 2018-03-26 Production Wells No Violations My inspection revealed that the well was equipped with a pumping unit and gas motor. This well produces into a shared tank battery with API permit number 2950. The tank battery consists of (2) 100 barrel tanks inside an earthen dike. I observed identification at the well and tank battery. Time of inspection: 11:30 AM. Weather: 47 degrees F, Sunny

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1039187364 US-OH-100432 2002-12-06 Well shall be plugged
1069283567 US-OH-101430 2003-11-19 Well insufficiently equipped to prevent escape of oil and gas
1069283567 US-OH-101431 2003-11-19 Unlawful venting or flaring of gas

For data sources see[8]

References