If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-089-26033 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.18,"lon":-82.58,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Licking | |
| Municipality: Liberty Township | |
| Operator Name: KNOX ENERGY INC. | |
| Well Pad ID: | |
| Farm/Lease Name: PRIBONIC D | |
| License Status: Producing | |
| License Date: 2010-12-09 | |
| Spud Date: 2011-01-19 | |
| Spud Drilling Contractor: KILBARGER DRLG | |
| Final Drill Date: 2011-01-24 | |
| Well Total Depth: 2322.00 ft | |
| Configuration: Vertical | |
| Latitude: 40.180000 | |
| Longitude: -82.580000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2009-12-11 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/11/2009, Expired Date:12/11/2010 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
| APP | 2010-12-09 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/9/2010, Expired Date:12/8/2012 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
| Reached Total Depth | 2011-01-24 | |
| Completion Report Received | 2011-06-30 | |
| Construction Permit Expires | 2012-12-08 | |
| Record Last Modified | 2017-10-24 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2011-09-02 | 2195 | 2210 | 16 |
| 2195 | 2210 | 16 | |
| 2195 | 2210 | 16 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| 2011-04-18 | H2O | 15 | 47567 Gal | 10000 | Producers Service Corporation |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2011 | KNOX ENERGY INC. | 6830.00 | 0.00 | 149 |
| 2012 | KNOX ENERGY INC. | 14483.00 | 0.00 | 366 |
| 2013 | KNOX ENERGY INC. | 9810.00 | 0.00 | 365 |
| 2014 | KNOX ENERGY INC. | 7706.00 | 0.00 | 365 |
| 2015 | KNOX ENERGY INC. | 5219.00 | 0.00 | 365 |
| 2016 | KNOX ENERGY INC. | 4720.00 | 0.00 | 365 |
| 2017 | KNOX ENERGY INC. | 5575.00 | 0.00 | 365 |
| 2018 | KNOX ENERGY INC. | 5053.00 | 0.00 | 365 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2011 | KNOX ENERGY INC. | Brine | 189 | 149 |
| 2012 | KNOX ENERGY INC. | Brine | 70 | 366 |
| 2013 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2014 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2015 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2016 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2017 | KNOX ENERGY INC. | Brine | 0 | 365 |
| 2018 | KNOX ENERGY INC. | Brine | 0 | 365 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -776414953 | 2011-9-14 0:00: | PL | No Violations | |
| 0776414953 | 2011-09-14 | Preliminary Restoration | No Violations | An inspection revealed that the Preliminary Restoration meets ORC 1509.072. The well is situated on a location designated as an agricultural field. A GPS reading was obtained for the well and tank location. The well was equipped and showed signs of production. The tank battery consisted of (1) 100bbl with no knockout tank, a sales meter, drip and vertical separator. Identification was displayed at the tank. |
For data sources see[9]