X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-089-26093

Well Details

Well ID: 34-089-26093
Loading map...
Country: United States
State: Ohio
County: Licking
Municipality: Eden Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: LOWRY WILLARD
License Status: Producing
License Date: 2012-04-04
Spud Date: 2012-05-07
Spud Drilling Contractor: MONROE DRILLING OPERATION, LLC
Final Drill Date: 2012-05-15
Well Total Depth: 2800.00 ft
Configuration: Vertical
Latitude: 40.180000
Longitude: -82.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-04-04 Proposed Formations:CLINTON, Issued Date:4/4/2012, Expired Date:4/4/2014 12:00:00 PM, Drilling unit acres:79.3, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2012-05-15
Completion Report Received 2012-08-17
Change of Owner 2014-02-06 Operator changed from 79, OXFORD OIL to 9216, ECLIPSE RESOURCES-OHIO LLC
Construction Permit Expires 2014-04-04
Change of Owner 2016-08-02 Operator changed from 9216, ECLIPSE RESOURCES-OHIO LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-08-24 2770 2797 24
2770 2797 24
2770 2797 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-08-01 H2O 28 1495 Bbl 300 Producers Service Corporation The first attempt to frac this well (see administrative report) resulted in casing failure, as circulation was observed on the backside (valve had been left open) of 4.5" casing. 300 gal of acid was staged with a breakdown pressure of 1946 psi. The incident occurred while on 0.5# sand. As a result, the job would shut down after completing flush. Oxford Oil Company would bring in Cemenco to run a flag to determine location of potential hole in the casing. They would pump approx 4bbl of fluid

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 OXFORD OIL 111.00 269.00 0
2013 ECLIPSE RESOURCES-OHIO LLC 352.00 1037.00 365
2014 ECLIPSE RESOURCES-OHIO LLC 55.00 1109.00 365
2015 ECLIPSE RESOURCES-OHIO LLC 128.00 809.00 365
2016 ECLIPSE RESOURCES-OHIO LLC 0.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 318.00 531.00 365
2018 M & R INVESTMENTS OHIO LLC 93.00 577.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 OXFORD OIL Brine 410
2013 ECLIPSE RESOURCES-OHIO LLC Brine 160 365
2014 ECLIPSE RESOURCES-OHIO LLC Brine 229 365
2015 ECLIPSE RESOURCES-OHIO LLC Brine 95 365
2016 M & R INVESTMENTS OHIO LLC Brine 10 365
2017 M & R INVESTMENTS OHIO LLC Brine 31 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1042124461 2012-8-31 0:00: PL No Violations
-1835760552 2012-8-1 0:00:0 CT No Violations
-906909937 2012-7-19 0:00: AM No Violations
0669915732 2012-07-25 Completion Testing Violations Noted An inspection revealed that the well was equipped with a gate valve and swage attached to 4.5 casing. The valve was open on swage and gasing from inside the 4.5 casing. The valve was also open on annulus between the 4.5 and 7 casing(s). Fluid was observed between 7 and 9.63 (conductor) annulus with no discharge or bubbling. The liners for (2) drilling pits have fallen and also contained rips therefore allowing fluid behind. High Range Quantabs were placed in the fluid and showed 7.8 units, which equals 3755 ppm (mg/L) Cl-. (3) 100 bbl frac tanks were observed at the location. A service rig was not observed at the location. A GPS reading was obtained and recorded for the wellbore. Notified Mr. Jack Greene with Oxford Oil Company.
0906909937 2012-07-19 Administrative Inspection Violations Noted During the surface job on a non-related well, it was alleged that casing failure had occurred on the frac job for this well. The 7/10/2012 frac job was not witnessed, due to insufficient notification. The required 24 hour notification was not met and would receive call from Mr. Jack Greene, a representative with the Oxford Oil Company, while frac job was just starting. Mr. Greene confirmed that he forgot to call sooner and agreed to meet the required notification for future jobs. Prior to hearing this alleged incident, I spoke with Mr. Greene, earlier this day at 9:39 AM by telephone in regards to the new Well Construction Rules (OAC) effective 8/1/2012. There was no mention of this incident. I called Mr. Greene at 4:52 PM, and confirmed casing failure on this frac job. Mr. Greene states they were 1/3 through frac job on sand, and with valve open on the annulus between 4.5 casing and 8 casing, circulation (not a full stream) was observed. They had good breakdown pressure and were on flush when this occurred. The 4.5 casing had been tested and they never lost pressure. The crew shutdown (did not complete frac) and would later bring in Cemenco to run a wireline, which showed possible hole or thread problem at 820. Mr. Greene states that they have scheduled Mr. Mike Wheelers service rig to repair casing (i.e. Pull tension, backoff casing below 820 and replace section of casing). Mr. Greene was again verbally instructed to provide sufficient notification and if problems were enountered on frac jobs.
1042124461 2012-08-31 Preliminary Restoration No Violations An inspection revealed that the Preliminary Restoration meets ORC 1509.072. The drilling pits have been abandoned, and the well location and lease road were graded. A uniform application of hay and straw were applied to the entire well and lease road locations. The well was equipped with a pumping unit and routed to a tank battery, which consisted of (1) 100 bbl tank with a separator, drip, meter, and surrounded by an earthen dike. A GPS reading was obtained for the well, tank battery, and access road locations.
1336562087 2012-05-08 Drill / Deepen / Reopen No Violations I witnessed the cementing of the surface casing.
1343650151 2012-07-27 Drill / Deepen / Reopen No Violations A follow-up inspection was conducted with Mr. Jack Greene from the Oxford Oil Company. Mr. Greene will resolve the deficiency with the pits today.
1835760552 2012-08-01 Completion Testing No Violations I witnessed the frac job today with Oxford Oil representative, Mr. Jack Greene. No problems were encountered during this job. Please refer to Stimulation Report for details. Additionally, Mr. Greene also addressed the fluid levels within the drilling pits and will completely abandon 8/6/12.
1867142461 2012-05-03 Drill / Deepen / Reopen No Violations An inspection revealed no activity or personnel at this time. The drilling rig is in the process of moving onto location.
669915732 2012-7-25 0:00: CT No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0669915732 US-OH-127575 2012-07-30 Pits unable to contain brine or other wastes
0669915732 US-OH-127576 2012-07-30 Pollution and contamination
0906909937 US-OH-130348 2012-07-30 Well stimulation; failure to protect USDW; failure to complete well integrity testing

For data sources see[9]

References