Well ID: 34-099-22996 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.12,"lon":-80.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: TOD HOMESTEAD CEMETERY | |
License Status: Producing | |
License Date: 2005-08-31 | |
Spud Date: 2006-03-08 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-03-15 | |
Well Total Depth: 5420.00 ft | |
Configuration: Directional | |
Latitude: 41.120000 | |
Longitude: -80.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-08-31 | Proposed Formations:ORISKANY/CLINTON, Issued Date:8/31/2005, Expired Date:8/31/2006 6:00:00 AM, Drilling unit acres:161.91, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2005-09-02 | TARGET LOCATION: 2050'NL & 11,100'WL OF TWP.; X= 2,503,825; Y= 537,675; ELEV.= 1095'. |
Original Spud | 2006-03-08 | RBDMS Rec |
Completed | 2006-03-15 | RBDMS Rec |
Reached Total Depth | 2006-03-15 | RBDMS Rec |
Completion Report Received | 2006-05-01 | RBDMS Rec |
Correction to Well | 2006-05-26 | CHANGE IN TARGET INFORMATION: FOOTAGE= 2170'NL & 11,285'WL OF TWP. TARGET X= 2,504,010. TARGET Y= 537,535 (SOURCE OF LOCATION: GPS ). |
Construction Permit Expires | 2006-08-31 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-07-13 | 5208 | 5292 | 78 |
5208 | 5292 | 78 | |
5208 | 5292 | 78 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 80000 Gal | 0 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | DUCK CREEK ENERGY INC | 2020.00 | 83.00 | 210 |
2007 | DUCK CREEK ENERGY INC | 8755.00 | 356.00 | 365 |
2008 | DUCK CREEK ENERGY INC | 8306.00 | 212.00 | 365 |
2009 | DUCK CREEK ENERGY INC | 6414.00 | 152.00 | 365 |
2010 | DUCK CREEK ENERGY INC | 8976.00 | 126.00 | 365 |
2011 | DUCK CREEK ENERGY INC | 9425.00 | 164.00 | 365 |
2012 | DUCK CREEK ENERGY INC | 8090.00 | 163.00 | 366 |
2013 | DUCK CREEK ENERGY INC | 5562.00 | 29.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 3736.00 | 86.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 3436.00 | 29.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 4604.00 | 122.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 4018.00 | 153.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 4615.00 | 76.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | DUCK CREEK ENERGY INC | Brine | 389 | 210 |
2007 | DUCK CREEK ENERGY INC | Brine | 360 | 365 |
2008 | DUCK CREEK ENERGY INC | Brine | 138 | 365 |
2009 | DUCK CREEK ENERGY INC | Brine | 170 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 155 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 124 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 121 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 46 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 19 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 16 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 54 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 52 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 88 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1154254329 | 2006-5-8 0:00:0 | PL | No Violations | 0.50 |
-1611292496 | 2018-7-12 0:00: | PW | No Violations | |
-658232915 | 2018-7-25 0:00: | PW | No Violations | 1.00 |
-732796657 | 2018-6-26 0:00: | PW | No Violations | 0.50 |
0573358442 | 2018-07-26 | Production Wells | No Violations | The purpose of my inspection was to follow-up on compliance notice #1611292496. At the time of my inspection Moore Well Services was on location to remove the plunger assembly and begin to convert the well to operate with a pump jack unit. No gas or fluid flow was observed from the well. The location remained stable. I will schedule a follow-up inspection to document the status of the well and installation of screened security fencing for compliance with 1501:9-9 (E). No further action is necessary. |
0658232915 | 2018-07-25 | Production Wells | No Violations | The purpose of my inspection was to follow-up on compliance notice # 732796657 . Inspector John Fleming was present during the inspection. I met with Duck Creek Energy representative Larry Gibler and discussed the scope of work and restoration of the location following the conversion. A workover rig operated by Moore Well Service was on location to remove the plunger lift assembly and replace the assembly with a pump jack unit. At the time of inspection the well had been blown down in preparation for the work and was no longer leaking. I will schedule a follow-up inspection to witness the repairs. No further action is necessary at this time. |
0732796657 | 2018-06-26 | Production Wells | Violations Noted | The purpose of my inspection was to conduct a status check inspection on well #2-2995. Inspector John Fleming was present during the inspection. RBDMS indicated reported production was current. Access to the well and tank battery remained drivable and stable through the Tod Cemetery. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was above grade and closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. I witnessed gas leaking from the tubing head assembly. Cloth rags were tied around the assembly. No free fluid was observed on the assembly or ground. A stable earthen dike that was free of fluid was present around the production equipment. A locked and screened chain-link fence enclosure was present on top of the dike. Correct identification was present on the fence. Equipment on location consisted of one (1) horizontal separator and two (2) steel production tanks. The separator remained in good repair. No production chart was present. The production tanks remained in good repair. Valves were closed and plugged. A charcoal filter was present. Hatch lids were closed. While on location I called and spoke with Duck Creek Energy representative Larry Gibler regarding the well leak. Mr. Gibler stated he was aware of the leak and had scheduled a service rig to replace the tubing. I communicated to Mr. Gibler that I was issuing a compliance notice due to the well being insufficiently equipped to prevent the escape of gas. I requested that the surface leak be repaired within 14 days and to be notified of when the service rig was to be on location due to the urban location of the well. I will schedule a follow-up inspection to document the status of repairs. |
1141998193 | 2006-03-02 | Drill / Deepen / Reopen | No Violations | Arrived on site for the surface job. Observed the running inof the surface pipe and the cementing in of the pipe. Good cement returns (14 bbls). |
1154254329 | 2006-05-08 | Preliminary Restoration | No Violations | The tank battery consists of 2-100 bbl storage tanks, 1-separator, a fence and a dike. The dike is not fully closed at this time since the well has no been put into operation as yet. The pits are closed. Partial compliance for preliminary restoration. |
1176314238 | 2007-04-05 | Preliminary Restoration | No Violations | The drilling pits were filled in. Vegetation was growing on the location. No erosion was visible. No drilling equipment on location. Pine trees around tank battery. This well and tank battery have passed the preliminary restoration. |
1606227356 | 2018-12-26 | Production Wells | No Violations | I performed a status check on the above location. A pumping Unit has been installed on this location. The well is in production. The tank battery is equipped with one 140 barrel tank and a horizonal separator. Valves are closed and plugged ID signs are posted No noted violations at this time |
1611292496 | 2018-07-12 | Production Wells | No Violations | The purpose of my inspection was to follow-up on compliance notice # 732796657. At the time of my inspection, the well was still leaking gas to atmosphere. The leak was less pronounced. The tubing was pressure gauge indicated 100 psi. While on location I called and spoke with Duck Creek representative Larry Gibler to regarding the status of the service rig to make repairs. Mr. Gibler stated the rig was scheduled to arrive in a few weeks. Mr. Gibler continued that he had blown the well down and was operating it at a lower pressure until repairs were finished. During the call I requested notification of when the rig arrived due to the urban location. I will schedule a follow-up inspection to document the status of repairs once completed. |
573358442 | 2018-7-26 0:00: | PW | No Violations | 4.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0732796657 | US-OH-128334 | 2018-10-04 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]