X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-23832

Well Details

Well ID: 34-111-23832
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Benton Township
Operator Name: TRIAD HUNTER LLC
Well Pad ID:
Farm/Lease Name: LAVOIE
License Status: Producing
License Date: 2003-03-20
Spud Date: 2003-06-20
Spud Drilling Contractor: DECKER WELL SERVICE
Final Drill Date: 2003-06-23
Well Total Depth: 2519.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -81.110000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-03-20 460 CARLTON OIL CORP Proposed Formation GORDON/BEREA Issued Date 3/20/2003 Expired Date 3/19/2004 6:00:00 AM
Correction to Well 2003-04-18 CORRECTION TO FOOTAGE: 30'NL & 2290'EL OF SEC. 25.
Inspector Comments Cement Job 2003-06-20 cementers late due to equiptment failure

(rearend went out of pump truck while enroute to location.Cement Ticket Notes Inspector Reporting BALL DAVID

Original Spud 2003-06-20 RBDMS Rec
Completed 2003-06-23 RBDMS Rec
Reached Total Depth 2003-06-23 RBDMS Rec
Completion Report Received 2003-10-06 RBDMS Rec
Construction Permit Expires 2004-03-19 RBDMS Rec
Change of Owner 2011-08-17 Operator changed from 460, CARLTON OIL CORP to 7434, VIRCO INC
Change of Owner 2018-08-21 Operator changed from 7434, VIRCO INC to 8610, TRIAD HUNTER LLC
Record Last Modified 2018-08-21 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-11-18 1864 1868 15
2003-11-18 1991 2383 47
1864 1868 15
1991 2383 47
1864 1868 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1547 Bbl 0 400 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 CARLTON OIL CORP 470.00 0.00 365
2004 CARLTON OIL CORP 847.00 64.00 365
2005 CARLTON OIL CORP 833.00 27.00 365
2006 CARLTON OIL CORP 897.00 0.00 365
2007 CARLTON OIL CORP 384.00 0.00 365
2008 CARLTON OIL CORP 214.00 50.00 365
2010 CARLTON OIL CORP 215.00 0.00 365
2011 VIRCO INC 26.00 0.00 75
2012 VIRCO INC 84.00 0.00 366
2013 VIRCO INC 165.00 0.00 365
2014 VIRCO INC 70.00 0.00 365
2015 VIRCO INC 212.00 0.00 365
2016 VIRCO INC 198.00 0.00 366
2017 VIRCO INC 0.00 0.00 0
2018 VIRCO INC 45.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 CARLTON OIL CORP Brine 100 365
2004 CARLTON OIL CORP Brine 0 365
2005 CARLTON OIL CORP Brine 0 365
2006 CARLTON OIL CORP Brine 0 365
2007 CARLTON OIL CORP Brine 0 365
2008 CARLTON OIL CORP Brine 0 365
2010 CARLTON OIL CORP Brine 0 365
2011 VIRCO INC Brine 0 75
2012 VIRCO INC Brine 0 366
2013 VIRCO INC Brine 0 365
2014 VIRCO INC Brine 0 365
2015 VIRCO INC Brine 43 365
2016 VIRCO INC Brine 0 366
2017 VIRCO INC Brine 0 0
2018 VIRCO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1683084624 2020-4-6 0:00:0 PW No Violations 0.30
-1738092286 2004-3-31 0:00: PL No Violations 1.00
-202170813 2017-10-19 0:00 PW No Violations 0.50
0202170813 2017-10-19 Production Wells No Violations On the day of my inspection, I found (1) 100 barrel steel tank, vertical separator, meter gauge, drip tank, and proper identification all contained within an earthen dike. Dike is shared with API 34-111-2-3950. The wellhead is equipped with 4.5 inch diameter casing and 2.5 inch diameter tubing with both valves open, and produced by means of a pumping unit. Production records are current.
1738092286 2004-03-31 Preliminary Restoration No Violations Location has been restored vegatation established lease road to well has been seeded,well was pumping on the day of my inspection.

Talked to pumper Gary McNight while conducting my inspection.

2008803084 2019-9-12 0:00: PW No Violations 0.50

For data sources see[9]

References