X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-24712

Well Details

Well ID: 34-111-24712
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Center Township
Operator Name: GULFPORT APPALACHIA LLC
Well Pad ID: US-OH-001439
Farm/Lease Name: PAULUS 210594
License Status: Producing
License Date: 2017-02-22
Spud Date: 2017-02-01
Spud Drilling Contractor:
Final Drill Date: 2017-04-03
Well Total Depth: 19790.00 ft
Configuration: Horizontal
Latitude: 39.740000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-01-19 Proposed Formations:TRENTON, Issued Date:1/19/2017, Expired Date:1/19/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-02-22 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:2/22/2017, Expired Date:2/22/2019 12:00:00 PM, Drilling unit acres:438.207, Proposed Well Type:OG, Proposed Well Class:EOUT
Record Last Modified 2018-02-08 STATUS PER AS-DRILLED PLAT
Correction to Well 2018-02-09 CHANGE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Construction Permit Expires 2019-02-22 STATUS PER AS-DRILLED PLAT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
16496 16652 0
10314 10466 0
10314 10466 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/13/2019 03/05/2019 9797 20,114,200.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SCALECHEK LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
FDP-S1296-17 Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Telmer Proprietary 10 0.00152308 2912
Crystalline silica, quartz 14808-60-7 100 12.052 23,038,200.0
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.0015961 3052
Glutaraldehyde 111-30-8 30 0.00957663 18307
Phosphoric acid 7664-38-2 0.1 0.00003192 62
Ethanol 64-17-5 1 0.000319221 611
Acrylic acid 79-10-7 0.01 0.00000152 3
Hydrochloric acid 7647-01-0 15 0.02027 38739
Propargyl alcohol 107-19-7 5 0.00001180 23
Methanol 67-56-1 100 0.000280664 538
Inorganic salt Proprietary 30 0.0343808 65722
Hydrotreated light petroleum distillate 64742-47-8 30 0.0343808 65722
Sodium polyacrylate 9003-04-7 1 0.000152308 292
Ethylene glycol 107-21-1 60 0.00913845 17469
Ethoxylated alcohols Proprietary 5 0.00001180 23
Acrylamide acrylate polymer Proprietary 30 0.0343808 65722
Modified thiourea polymer Proprietary 30 0.00007079 136
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.239497 457817
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 87.6509 167,551,000.0
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
EXCELERATE PS-2 Halliburton Friction Reducer Listed Below Listed Below 0 0 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1156043904 2019-2-13 0:00: CT No Violations 0.50
-2084584361 2018-9-24 0:00: CT No Violations 0.30
0645936157 2018-06-18 Completion Testing No Violations On this day, I am conducting an inspection per request of ODNR Inspector William Stolarik. I spoke with Company Man, Ken Miller, during my inspection. (10) wells were drilled on the pad. They are currently plumbing the intermediate and surface casing, at the wellhead, and preparing to install pressure monitoring devices. The grates will be replaced over the cellar, when they are finished.
0771714813 2019-05-16 Completion Testing No Violations On this day, I found the drilling and hydraulic fracturing processes are completed. The frac plugs have been drilled out and the well is currently in the flowback stage. I spoke with Gulfport Representatives Corey Cloud and Robert Coots during the inspection. Annular pressure monitoring devices are in place and pressures are logged daily. Identification is posted at the wellhead.
1156043904 2019-02-13 Completion Testing No Violations On this day, I am conducting an inspection during the completion process, and found Halliburton Pressure Pumping Service onsite along with Reach Wireline. They are zipper fracing between permit numbers 4712 (3B) and 4715 (1B). I spoke with Gulfport Company Man Dave Cole during the inspection. They are preparing to complete stage 1 of 47 with 28 shots, divided into 4 clusters. The frac plug for stage 2 will be set at a measured depth of 19,471 feet. Mr. Cole stated that annular pressures for the 13.375 inch diameter casing and 9.625 inch diameter casing are monitored and logged daily for all (10) wells on the pad. He also stated that only 5 of 10 wells will be completed at this time.
1486242714 2017-02-04 Drill / Deepen / Reopen No Violations On the day inspection I witnessed that Lightning Energy Services had drilled a 36 inch diameter hole to the depth of 107 feet, hitting water at 40 feet and ran 107 feet of 26 inch diameter 85.6 pounds per foot conductor pipe. Stingray Pressure Pumping was onsite and pumped 2 barrels of fresh water, performed a 500 pounds per square inch pressure test, gained circulation with 20 barrels of fresh water, pumped 15 barrels of gel, pumped 10 barrels of fresh water and cemented pipe with 410 sacks Class A cement with 2% CaCl and .25 pound per sack of Celluseal weighing 15.6 pounds per gallon and a yield of 1.2 cubic foot per sack. Cement was weight was verified with pressurized mud scales and displaced to 100 feet with 61 barrels of fresh water with good cement returns of 15 barrels to surface. Mix water was tested revealing chlorides of 60 parts per million, pH 7 and 54 degrees.
1489924089 2017-03-19 Casing String Witnessed No Violations On site inspection to witness the surface casing cement job with Pineer Drilling rig # 73 and O-Tex cement service. The rig has drilled a 17.5 surface borehole to a measured depth of 1,405 and ran 13.375 diameter J-55 Grade Buttress thread casing to 1,405 with the rig circulating the last casing joint n and establishing circulation prior to cementing. O-Tex cement service cemented the casing using a 267 barrel cement mix consisting of 1,240 sacks of class H cement with the cement weight verified by weight of scale. The cement was displaced to the float collar set at 1,362 with 210 barrels of fresh water and the casing was pressure tested to 500 psi over cement displacement pressure upon the landing of the cement plug. Cement returns were witnessed to surface inside the cellar.
1491331902 2017-04-04 Drill / Deepen / Reopen No Violations
2084584361 2018-09-24 Completion Testing No Violations Status update inspection found a total of 10 wells present on this well pad. All 10 have been drilled and not completed. Each well is equipped with a lower A and upper well head section with 2 diameter riser pipes present on each section with valves and gauges present on each section for annular pressure monitoring. The casing head does have a multi valve set up with a mechanical gauge present. No tubing is in the well. No production equipment is present on the well pad other than the 3rd party mid stream pipeline. The well pad does have an earthen berm in place. The well pad surface and lease road is of stone construction and in good repair. Addressing the preliminary restoration. There is an area along the lease road that is within the well site boundary that was recently disturbed by the installation of a transportation pipeline. There is also a area on the West side of the well pad that was disturbed and vegetation not established. Larger diameter wooden poles are set on the East side of the well pad along the pad surface boundary for sound barrier during stimulation. There are (2) 12 diameter trunk lines that have been laid along the well pad perimeter, these lines are fresh water lines to support the stimulation process. The lease road does have a gate present.
645936157 2018-6-18 0:00: CT No Violations 0.10
771714813 2019-5-16 0:00: CT No Violations 0.10

For data sources see[5]

References