| Well ID: 34-115-22953 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.63,"lon":-81.67,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Morgan | |
| Municipality: Center Township | |
| Operator Name: GENESIS RESOURCES LLC | |
| Well Pad ID: | |
| Farm/Lease Name: SILVUS COOLEY ESTATE | |
| License Status: Producing | |
| License Date: 1982-10-04 | |
| Spud Date: 1982-11-15 | |
| Spud Drilling Contractor: PERKINS DRLG | |
| Final Drill Date: 1982-11-19 | |
| Well Total Depth: 5438.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.630000 | |
| Longitude: -81.670000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| CO | 1982-10-04 | 471 EAGLE MOUNTAIN ENERGY GeoDate 10/4/82 |
| Oil and Gas | 1982-10-04 | Issued Date 10/4/82 Expired Date 4/2/83 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05438 Proposed Drill Depth 05438 |
| Original Spud | 1982-11-15 | |
| Completed | 1982-11-19 | |
| Reached Total Depth | 1982-11-19 | |
| Completion Report Received | 1983-03-16 | |
| Construction Permit Expires | 1983-04-02 | |
| Change of Owner | 1999-04-30 | Operator changed from 471, EAGLE MOUNTAIN ENERGY to 4801, BANCEQUITY PETROLEUM CORP |
| Last Compliance Report | 2018-04-18 | |
| Change of Owner | 2018-05-04 | Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 9086, GENESIS RESOURCES LLC |
| Record Last Modified | 2018-05-04 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 1997-06-29 | 5151 | 5207 | 0 |
| 5151 | 5207 | 0 | |
| 2006-09-11 | 5178 | 5268 | 71 |
| 5178 | 5268 | 71 | |
| 5151 | 5207 | 0 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| N2 | 0 | 100 | 0 | SCDF N2 | ||
| H2O | 0 | 1500 Bbl | 50000 | FRAC;1500BBL H2O,50M# SAND,100MCF N2 |
For data sources see[4]
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1330403863 | 2018-2-8 0:00:0 | TD | No Violations | |
| -1618266353 | 2020-7-8 0:00:0 | PW | No Violations | 0.50 |
| -322243581 | 2018-2-8 0:00:0 | PW | No Violations | 1.00 |
| 0000PL9880 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
| 0322243581 | 2018-02-08 | Production Wells | No Violations | I was on location today to do a follow-up inspection on this well. At this time the well is still idle and incapable of production. The production valves are shut at the wellhead preventing the well from production. I did find a hole in the side of the wellhead. There is no gas coming out of it at this time. The last reported production on this well was back in 2011. The well is still currently in violation. I did take updated photos of the well for my inspection today. |
| 0365517066 | 2004-03-15 | Production Wells | No Violations | No violations noted on the day of my inspection. |
| 0386262219 | 2017-03-09 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a plunger lift system, a 4 1/2 inch diameter wellhead, 2 inch diameter production lines, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank and a horizontal separator with proper identification on it. There has been no resolution to the issues with this well and the well is idle at the time of inspection. |
| 0680044282 | 2017-01-23 | Production Wells | Violations Noted | The inspection this day revealed that this well is equipped with a plunger lift system, a 4 1/2 inch diameter wellhead, 2 inch diameter production lines, and 1 1/2 inch diameter production tubing. The valves on the wellhead are closed at the time of inspection. The tank battery for this well is equipped with a 100 barrel steel tank and a horizontal separator with proper identification on it. The records for this well in RBDMS show that the company has reported zero production for this well since 2002. This well is idle at the time of inspection. Bancequity Petroleum Corp shall submit a written plugging schedule to the Brian Sefciks office at 5880 Memory Rd Zanesville Ohio, 43701-9553 within 30 days and plug the well within 180 days. Bancequity Petroleum Corp will be notified if the plugging schedule is approved or denied. |
| 1021619509 | 2009-08-24 | Annular Disposal | No Violations | Checked AD hook up for Columbus, AD not in use. |
| 1330403863 | 2018-02-08 | Temporary Abandoned Annular Disposal | No Violations | I was on location today to check the annular disposal for Columbus. The annular disposal is not hooked up on this well. |
| 365517066 | 2004-3-15 0:00: | PW | No Violations | |
| 386262219 | 2017-3-9 0:00:0 | PW | No Violations | 1.00 |
| 680044282 | 2017-1-23 0:00: | PW | No Violations | 1.00 |
| 989666610 | 2020-6-2 0:00:0 | PW | No Violations | 0.50 |
| PL9880 | PL | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0680044282 | US-OH-127692 | 2017-01-31 | NONE | Well shall be plugged |
For data sources see[9]