Well Details

Well ID: 34-121-21939
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Jackson Township
Operator Name: STONEBRIDGE OPERATING CO LLC
Well Pad ID:
Farm/Lease Name: SLATER D
License Status: Final Restoration
License Date: 2016-04-12
Spud Date: 1977-05-10
Spud Drilling Contractor: J & B DRILLING
Final Drill Date: 1978-02-15
Well Total Depth: 5650.00 ft
Configuration: Vertical
Latitude: 39.650000
Longitude: -81.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1976-12-10 2098 OPI INC GeoDate 12/10/76
Unknown 1976-12-10 Issued Date 12/10/76 Expired Date 12/10/77 Acres 0000000 Tool Type RTA Proposed Formation Proposed Depth 05650 Proposed Drill Depth 05650
Original Spud 1977-05-10 R.L. 3-16-77
Completed 1978-02-15 R.L. 3-16-77
Reached Total Depth 1978-02-15 R.L. 3-16-77
Completion Report Received 1978-03-03 R.L. 3-16-77
CO 1994-06-28 631 BT ENERGY CORP GeoDate 12/10/76
APP 2005-08-30 Proposed Formations:BEREA/DEVONIAN SHALE, Issued Date:8/30/2005, Expired Date:8/30/2006 6:00:00 AM, Drilling unit acres:87.01, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2007-03-15 Proposed Formations:BEREA/DEVONAIN SHALE/ORISKANY, Issued Date:3/15/2007, Expired Date:3/14/2008 6:00:00 AM, Drilling unit acres:87.01, Proposed Well Type:OG, Proposed Well Class:POOL
Change of Owner 2007-10-12 Operator changed from 631, BT ENERGY CORP to 2070, STONEBRIDGE OPERATING CO
APP 2008-04-14 Proposed Formations:BEREA/ORISKANY/DEVONIAN SHALE, Issued Date:4/14/2008, Expired Date:4/14/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:ENPW
APP 2011-10-07 Proposed Formations:BEREA, DEVONIAN SHALE, ORISKANY, Issued Date:10/7/2011, Expired Date:10/6/2013 12:00:00 PM, Drilling unit acres:87.01, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2016-04-12 Proposed Formations:DEVONIAN SHALE, Issued Date:4/12/2016, Expired Date:4/12/2018 12:00:00 PM, Drilling unit acres:87.01, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged/Abandoned 2017-05-24 R.L. 3-16-77
Record Last Modified 2017-06-22 R.L. 3-16-77
Construction Permit Expires 2018-04-12 R.L. 3-16-77

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5492 5543 18
5492 5543 18
5492 5543 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BT ENERGY CORP 5362.00 0.00 365
1985 BT ENERGY CORP 3673.00 0.00 365
1986 BT ENERGY CORP 3903.00 0.00 365
1987 BT ENERGY CORP 2411.00 0.00 365
1988 BT ENERGY CORP 2723.00 0.00 365
1989 BT ENERGY CORP 5714.00 0.00 365
1990 BT ENERGY CORP 1760.00 0.00 365
1993 BT ENERGY CORP 1109.00 0.00 365
1994 BT ENERGY CORP 606.00 0.00 365
1995 BT ENERGY CORP 447.00 0.00 0
1996 BT ENERGY CORP 2328.00 0.00 0
1997 BT ENERGY CORP 3727.00 0.00 0
1998 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2000 STONEBRIDGE OPERATING CO LLC 0.00 0.00 350
2001 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2002 BT ENERGY CORP 0.00 0.00 0
2003 BT ENERGY CORP 0.00 0.00 0
2004 BT ENERGY CORP 0.00 0.00 0
2005 BT ENERGY CORP 0.00 0.00 0
2006 BT ENERGY CORP 0.00 0.00 0
2007 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2008 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2009 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2010 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2011 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2012 STONEBRIDGE OPERATING CO LLC 104.00 0.00 0
2013 STONEBRIDGE OPERATING CO LLC 82.00 0.00 0
2014 STONEBRIDGE OPERATING CO LLC 28.00 0.00 0
2015 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2016 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0
2017 STONEBRIDGE OPERATING CO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BT ENERGY CORP Brine 0 365
1985 BT ENERGY CORP Brine 0 365
1986 BT ENERGY CORP Brine 0 365
1987 BT ENERGY CORP Brine 0 365
1988 BT ENERGY CORP Brine 0 365
1989 BT ENERGY CORP Brine 0 365
1990 BT ENERGY CORP Brine 0 365
1993 BT ENERGY CORP Brine 0 365
1994 BT ENERGY CORP Brine 0 365
1995 BT ENERGY CORP Brine 0 0
1996 BT ENERGY CORP Brine 0 0
1997 BT ENERGY CORP Brine 0 0
1998 STONEBRIDGE OPERATING CO LLC Brine 0 0
2000 STONEBRIDGE OPERATING CO LLC Brine 0 350
2001 STONEBRIDGE OPERATING CO LLC Brine 0 0
2002 BT ENERGY CORP Brine 0 0
2003 BT ENERGY CORP Brine 0 0
2004 BT ENERGY CORP Brine 0 0
2005 BT ENERGY CORP Brine 0 0
2006 BT ENERGY CORP Brine 0 0
2007 STONEBRIDGE OPERATING CO LLC Brine 0 0
2008 STONEBRIDGE OPERATING CO LLC Brine 0 0
2009 STONEBRIDGE OPERATING CO LLC Brine 0 0
2010 STONEBRIDGE OPERATING CO LLC Brine 0 0
2011 STONEBRIDGE OPERATING CO LLC Brine 0
2012 STONEBRIDGE OPERATING CO LLC Brine 72 0
2013 STONEBRIDGE OPERATING CO LLC Brine 72 0
2014 STONEBRIDGE OPERATING CO LLC Brine 0 0
2015 STONEBRIDGE OPERATING CO LLC Brine 0 0
2016 STONEBRIDGE OPERATING CO LLC Brine 0 0
2017 STONEBRIDGE OPERATING CO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1278567587 2014-8-4 0:00:0 PW No Violations 1.50
-1506484810 2014-9-22 0:00: PW No Violations 2.00
-1877776063 2014-11-12 0:00 PW No Violations 1.50
-1990508827 2006-11-6 0:00: PW No Violations
-2004072403 2017-5-24 0:00: PB No Violations 5.00
-223774724 2013-11-6 0:00: PW No Violations 1.00
-2849950 2014-11-7 0:00: PW No Violations 3.00
0002849950 2014-11-07 Production Wells No Violations My inspection today finds the company has moved in a Matheny Well Service rig to attempt to repair the well. There are no personnel onsite. The tubing has broken completely off of the well and the wellhead has been partially partially disassembled. A valve on the 4.5 casing wellhead is open and a small amount of gas is flowing out of it.
0223774724 2013-11-06 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing and 1.5 tubing. The tubing has a rotted off at the top of the well head. A significant amount of gas is leaking from the tubing. A production unit is present off site but is not hooked up. The well is not capable of production.
0816818718 2016-03-02 Production Wells No Violations My inspection today finds the well is not capable of production. No gas or oil transportation pipelines are attached to the wellhead. All of the valves at the wellhead are shut. The off site production unit is not connected to any pipelines.
0926906401 2009-10-21 Production Wells No Violations FOLLOW UP TO NOV # 1259784279 Inspected site along with supervisor and determined that well is idle and incapable of producing in its present state of repair,it is equipped with 8 surface casing and 4.5 production casing and 1.5 tubing which has hole in it at tubing head,the last production reported was back in 1998 and I have had several conversations with company rep requesting that they plug or produce said well.
0939117533 2014-10-28 Administrative Inspection No Violations I received a telephone call from John Schneider, Production Supervisor for Stonebridge Operating, indicating that the company intended to make an attempt to repair the well in the next few days.
1097896989 2014-02-25 Production Wells No Violations My inspection finds the well is equipped with 4.5 casing and 1.5 tubing. The tubing has a large hole in it at the top of the 4.5 by 1.5 wellhead. Gas can be heard leaking. The casing appears to have partially collapsed at the top of the 8 and is beginning to lean. A production unit is present off site. There is no tank for this well. The company reported gas production for the well in 2012, as well as 72 bbl of brine. Previous inspections have indicated the well is not capable of production. I called and left a message for John Snyder to call me to discuss this well at 12:06 pm.
1259784279 2009-10-21 Production Wells Violations Noted Inspected site along with supervisor and determined that well is idle and incapable of producing in its present state of repair,it is equipped with 8 surface casing and 4.5 production casing and 1.5 tubing which has hole in it at tubing head,the last production reported was back in 1998 and I have had several conversations with company rep requesting that they plug or produce said well.
1278567587 2014-08-04 Production Wells No Violations My inspection finds the well is equipped with 4.5 casing and 1.5 tubing. The tubing has a large hole at the top of the 4.5 by 1.5 wellhead. The casing appears to have partially collapsed at the top of the surface casing head.
1415664647 2014-11-10 Work Over Reconditioning No Violations My inspection today finds Matheny Well Service is attempting to utilize a tubing spear to pull the 1.5 tubing out of the wellhead. The Stonebridge representative, John Schneider, stated that he believed the tubing has crimped a little at the wellhead slips and is preventing the tubing spear from entering the tubing enough to pull it. Another attempt will be made on Wednesday.
1434987604 2015-06-22 Production Wells No Violations My inspection today finds the well is not capable of production. There are no gas or oil transportation pipelines attached to the wellhead. All of the valves at the wellhead are shut. The off site production unit is not connected to any pipelines. No tank associated with this well can be found.
1439399449 2015-08-11 Production Wells No Violations My inspection today finds the well is not capable of production. There are no gas or oil transportation pipelines attached to the wellhead. All of the valves at the wellhead are shut. The off site production unit is not connected to any pipelines.
1440000335 2015-08-19 Production Wells No Violations My inspection today finds the well is not capable of production. No gas or oil transportation pipelines are attached to the wellhead. All of the valves at the wellhead are shut. The off site production unit is not connected to any pipelines. No tank associated with this well can be found.
1448288436 2015-11-23 Production Wells No Violations My inspection today finds the well is shut in and all pipelines are disconnected from the well. There is no means of monitoring pressure on the well. The production unit is disconnected from any pipelines and there is no tank.
1495488114 2017-05-22 Plug / Plug Back No Violations The purpose of my inspection is to witness plug back operations. The well prior to plug back operations was a total depth of 5650 with 8.625 inch diameter surface casing at 532 feet, 4.5 inch diameter production casing at a depth of 5650 feet, 2.875 inch diameter intermediate set on a packer at 30 feet, and 1.5 inch diameter tubing 4554 feet deep. The new proposed total depth is 3929 feet and the plans are to produce from the Devonian Shale formation. Huffman Bowers is on location with their service rig, pump truck, water truck and cement truck. The 1.5 inch diameter tubing is stuck within the 4.5 inch diameter production casing. The service rig tagged the inside of the 1.5 inch diameter tubing at 4800 feet in depth. Jet Wireline rigged up and ran down to 4604 feet and attempted to shoot the tubing free. The first and second attempt was unsuccessful shots did not fire. The shots were fired at 4604 feet on the third attempt but the wireline became stuck down hole. The wireline was retrieved but the collar locator was not retrievable.
1496928583 2017-06-08 Final Restoration No Violations The purpose of my inspection was a status check on a final restoration. During my inspection the well location and the lease road had been restored. The pit used in plugging operations had been closed. The area surrounding the plugged well and the lease road had been graded, seeded, and mulched. Vegetation had been established. All production equipment and debris from plugging operations had been removed. The location meets 1509.072 (B) Final Restoration requirements.
1506484810 2014-09-22 Production Wells No Violations My inspection today finds the status of the well has not changed. The well is still incapable of production. The 1.5 tubing has a large hole in it and the entire well is leaning. Gas is still escaping from the hole in the tubing.
1834179882 2013-07-11 Administrative Inspection No Violations I called and spoke to Mr. John Snyder. I told him that the plug back permit for the well would be expiring soon and that something needed to be done with the well. Mr. Snyder stated that he intended to begin work on the well in the next two months weather permitting.
1877776063 2014-11-12 Production Wells No Violations My inspection today finds the service rig crew has successfully used a spear to pull the tubing enough to strip the 4.5 by 1.5 tubing wellhead off. 2.875 tubing with a packer was placed over the 1.5 tubing. The packer was set and the tubing was then packed off in a wellhead on the 2.875 tubing string. The service rig was unable pull the tubing. John Schneider of Stonebridge Operating believes the tubing is stuck in the well at considerable depth.
1990508827 2006-11-06 Production Wells No Violations Plug back permit expired 8/30/06 will call company and discuss future plans for well at present time well is setting idle!
2004072403 2017-05-24 Plug / Plug Back No Violations The purpose of my inspection is to witness plugging operations. The service rig pulled the 4.5 inch diameter casing up 50 feet from the rip at 1920 feet and set a 100 foot isolation plug with class A cement within the open 7.875 inch diameter open hole from 1870 feet to 1770 feet. The 4.5 inch casing was pulled up to 1642 feet and the Berea plug was set within the 7.875 inch diameter open hole from 1642 feet to 1490 feet with class A cement. The 4.5 inch casing was pulled up to 611 feet to set the bottom of surface casing plug from 611 feet to 411 feet in depth with class A cement. The 4.5 inch diameter casing was removed from the hole and a 150 foot surface plug was set using class A cement. Cement stayed at the surface. A compliance notice issued for this well in 2009 states violations 1501: 9-9-05(A)(10) Failure to legibly identify well and 1509:12B Well shall be plugged. The plugging of this well resolves all violations from compliance notice 1259784279.
2044504191 2015-10-23 Production Wells No Violations My inspection today finds the well is not capable of production. No gas or oil transportation pipelines are attached to the wellhead. All of the valves at the wellhead are shut. The off site production unit is not connected to any pipelines.
2129607595 2014-02-28 Administrative Inspection No Violations I called Mr. John Snyder of Stonebridge Operating at 11:17 am. I discussed the outstanding violations against the well with Mr. Snyder. Mr. Snyder stated that he was planning to get a permit to plug the well. He also stated that the proper identification would be in place by 3/7/14.
816818718 2016-3-2 0:00:0 PW No Violations 1.00
926906401 2009-10-21 0:00 PW No Violations
939117533 2014-10-28 0:00 AM No Violations 0.40

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1259784279 US-OH-107002 2009-12-02 Failure to legibly identify well
1259784279 US-OH-107003 2009-12-02 Well shall be plugged

For data sources see[9]