34-121-24129

Well Details

Well ID: 34-121-24129
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Olive Township
Operator Name: INTERNATIONAL CONVERTER LLC
Well Pad ID:
Farm/Lease Name: INTERNATIONAL CONVERTER
License Status: Producing
License Date: 2005-02-08
Spud Date: 2005-02-18
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 2005-02-22
Well Total Depth: 1890.00 ft
Configuration: Vertical
Latitude: 39.720000
Longitude: -81.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-02-08 Proposed Formations:BEREA/GANTZ/30 FOOT/GORDON, Issued Date:2/8/2005, Expired Date:2/8/2006 6:00:00 AM, Drilling unit acres:21.2069, Proposed Well Type:OG, Proposed Well Class:EDPW
Original Spud 2005-02-18 RBDMS Rec
Completed 2005-02-22 RBDMS Rec
Reached Total Depth 2005-02-22 RBDMS Rec
Completion Report Received 2005-03-14 RBDMS Rec
Change of Owner 2005-07-19 Operator changed from 1389, BROWN WP ENTERPRISES INC to 7877, INTERNATIONAL CONVERTER INC
Construction Permit Expires 2006-02-08 RBDMS Rec
Change of Owner 2018-02-07 Operator changed from 7877, INTERNATIONAL CONVERTER INC to 10082, INTERNATIONAL CONVERTER LLC
Record Last Modified 2018-02-07 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-06-01 1344 1798 78
1344 1798 78
1344 1798 78

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 3238 Bbl 43000 1500 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 INTERNATIONAL CONVERTER INC 0.00 78.00 365
2013 INTERNATIONAL CONVERTER INC 4030.00 10.00 365
2014 INTERNATIONAL CONVERTER INC 3690.00 85.00 365
2015 INTERNATIONAL CONVERTER INC 3340.00 10.00 365
2016 INTERNATIONAL CONVERTER INC 3251.00 9.00 365
2017 INTERNATIONAL CONVERTER INC 2372.00 6.00 365
2018 INTERNATIONAL CONVERTER LLC 3130.00 8.00 334

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 INTERNATIONAL CONVERTER INC Brine 40 365
2013 INTERNATIONAL CONVERTER INC Brine 0 365
2014 INTERNATIONAL CONVERTER INC Brine 0 365
2015 INTERNATIONAL CONVERTER INC Brine 0 365
2016 INTERNATIONAL CONVERTER INC Brine 0 365
2017 INTERNATIONAL CONVERTER INC Brine 0 365
2018 INTERNATIONAL CONVERTER LLC Brine 0 334

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1731737133 2019-3-4 0:00:0 PW No Violations 0.80
1108853551 2005-02-18 Drill / Deepen / Reopen No Violations Stopped by drilling rig for update they were setting conductor pipe set 44 of 9.625 conductor hole dusted,rig shutting down for the weekend.
1122041800 2005-07-18 Preliminary Restoration No Violations Upon inspecting site for compliance of restoration,found location restored and chain link fence constructed around wellhead and tank battery,dike constructed.

Well is equipped with 1-100bbl production tank,separator,rabbit well.

1333111726 2012-03-30 Production Wells No Violations Inspection of well head found the following equipment 4.5 production casing -1.5 tubing -with the production valves open and well being produced by means of a pumping unit -100 barrel tank and separator with proper identification and an established dike located on site all in a fenced in enclosure.
1603805766 2020-10-27 0:00 PW No Violations 0.30
1731737133 2019-03-04 Production Wells No Violations On the day of my inspection I witnessed production equipment included a 25-barrel plastic production fluid storage tank, vertical separator, drip all contained within an earthen dike. The well was equipped with 7-inch diameter surface casing, 4.5-inch diameter production casing, 1.5-inch diameter tubing with rods, a JC Pump Pumping unit, and an electric motor. The location was surrounded by a chain link fence, identification was present, and production was reported for 2017.
1765835971 2016-06-16 Production Wells No Violations My inspection today finds the well is equipped with a pumping unit. The tank battery consists of a separator and an 1100 gallon tank. All equipment is set in a chain link fence.

For data sources see[9]

References