Well Details

Well ID: 34-121-24260
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Marion Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: CARPENTER D
License Status: Producing
License Date: 2008-02-25
Spud Date: 2008-10-19
Spud Drilling Contractor: G & L DRILLING
Final Drill Date: 2008-10-22
Well Total Depth: 4280.00 ft
Configuration: Vertical
Latitude: 39.840000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-25 Proposed Formations:BEREA THRU ORISKANY, Issued Date:2/25/2008, Expired Date:2/24/2009 6:00:00 AM, Drilling unit acres:149.18, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2008-10-22 LOGGER'S TD MEASURED IN CASED HOLE
Construction Permit Expires 2009-02-24 LOGGER'S TD MEASURED IN CASED HOLE
Completion Report Received 2009-03-27 LOGGER'S TD MEASURED IN CASED HOLE
Change of Owner 2014-02-06 Operator changed from 79, OXFORD OIL to 9216, ECLIPSE RESOURCES-OHIO LLC
Change of Owner 2016-08-02 Operator changed from 9216, ECLIPSE RESOURCES-OHIO LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2016-08-04 LOGGER'S TD MEASURED IN CASED HOLE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-29 1604 1668 22
2009-06-29 1494 1514 15
1494 1514 15
1604 1668 22
1740 1784 13
1850 1946 31
1990 2004 4
1494 1514 15
2009-06-29 1740 1784 13
2009-06-29 1990 2004 4
2009-06-29 1850 1946 31

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 6118 Bbl 80000 TREATED SANDSTONE UNITS IN THE OHIO SHALE: GANTZ, THIRTY-FOOT, GORDON, AND FIFTH …
H2O 0 6260 Bbl 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 OXFORD OIL 6.00 0.00 0
2009 OXFORD OIL 8284.00 366.00 0
2010 OXFORD OIL 5127.00 187.00 365
2011 OXFORD OIL 3336.00 28.00 0
2012 OXFORD OIL 2417.00 77.00 0
2013 ECLIPSE RESOURCES-OHIO LLC 2157.00 0.00 365
2014 ECLIPSE RESOURCES-OHIO LLC 1678.00 66.00 365
2015 ECLIPSE RESOURCES-OHIO LLC 1284.00 107.00 365
2016 ECLIPSE RESOURCES-OHIO LLC 0.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 1289.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 863.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 OXFORD OIL Brine 1530
2009 OXFORD OIL Brine 2840
2010 OXFORD OIL Brine 380 365
2011 OXFORD OIL Brine 93
2012 OXFORD OIL Brine 0
2013 ECLIPSE RESOURCES-OHIO LLC Brine 395 365
2014 ECLIPSE RESOURCES-OHIO LLC Brine 70 365
2015 ECLIPSE RESOURCES-OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 21 365
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-94333339 2010-4-5 0:00:0 PL No Violations
0094333339 2010-04-05 Preliminary Restoration No Violations Restoration work at site satisfactory, pit has been filled and site restored and vegetation has been established.

Note: Well is equipped with pumping unit and tubing and rods and 2-100 bbl tanks and separator located within dike area.

1435334091 2014-04-29 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing and 1.5 tubing with a rods and a pump jack. The tank battery consists of one 100 bbl tank, one 30 bbl tank, a separator, and a meter. The tank has proper identification and is located inside of a dike.
1616941702 2012-04-25 Preliminary Restoration No Violations Inspection found 4.5 production casing -1.5 tubing with the production valves open and the well being produced by the means of a pumping unit , A 100 barrel tank -1600 gallon plastic tank -separator and meter with current chart are present in an established dike with proper well identification present.

For data sources see[9]