If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-24387 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.86,"lon":-81.42,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Seneca Township | |
Operator Name: ANTERO RESOURCES CORPORATION | |
Well Pad ID: US-OH-000520 | |
Farm/Lease Name: WAYNE UNIT | |
License Status: Producing | |
License Date: 2012-10-30 | |
Spud Date: 2012-10-27 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2012-12-13 | |
Well Total Depth: 14600.00 ft | |
Configuration: Horizontal | |
Latitude: 39.860000 | |
Longitude: -81.420000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-10-30 | Proposed Formations:POINT PLEASANT-BLACK RIVER, Issued Date:10/30/2012, Expired Date:10/30/2014 12:00:00 PM, Drilling unit acres:510.719, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2012-12-13 | |
Correction to Well | 2013-04-05 | UNIT SIZE CHANGED TO 363.40 ACRES. CORRECTION TO TARGET INFORMATION: FOOTAGE & X,Y COORDINATES FROM AS DRILLED SURVEY PLAT. |
Completion Report Received | 2013-06-26 | |
End of Confidential Data | 2013-12-13 | |
Construction Permit Expires | 2014-10-30 | |
Record Last Modified | 2017-04-18 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-07-03 | 7908 | 14407 | 0 |
7908 | 14407 | 0 | |
7908 | 14407 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/01/2013 | 04/01/2013 | 7,592 | 9,589,230 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SI-1000 | U.S. Well Services, LLC | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 20.00 | 0.00391 | |
Anionic Copolymer | Proprietary | Proprietary | ||||||
Water | 7732-18-5 | 30.00 | 0.00326 | |||||
LGC-15 | U.S. Well Services, LLC | Gelling Agents | Suspending agent (solid) | 14808-60-7 | 3.00 | 0.06887 | ||
Guar Gum | 9000-30-0 | 50.00 | 0.00498 | |||||
Petroleum Distillates | 64742-47-8 | 60.00 | 0.06887 | |||||
Surfactant | 68439-51-0 | 3.00 | 0.06887 | |||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100.00 | 9.51821 | ||
AP One | U.S. Well Services, LLC | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100.00 | 0.00136 | ||
Water | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 90.30508 | |||
AI-300 | U.S. Well Services, LLC | Acid Corrosion Inhibitors | 2-Butoxyethanol | 111-76-2 | 7.00 | 0.00002 | ||
Ethoxylated Nonylphenol | 68412-54-4 | 5.00 | 0.00001 | |||||
Triethyl Phosphate | 78-40-0 | 3.00 | 0.00001 | |||||
N,N-Dimethylformamide | 68-12-2 | 15.00 | 0.00003 | |||||
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 13.00 | 0.00003 | |||||
Water | 7732-18-5 | 20.00 | 0.00005 | |||||
Ethylene Glycol | 107-21-1 | 31.00 | 0.00008 | |||||
Cinnamaldehyde | 104-55-2 | 5.00 | 0.00001 | |||||
Isopropyl Alcohol | 67-63-0 | 3.00 | 0.00001 | |||||
HCL Acid (12.5-18.0) | U.S. Well Services, LLC | Bulk Acid | Hydrogen Chloride | 1/1/7641 | 18.00 | 0.02228 | ||
Water | 7732-18-5 | 87.50 | 0.05356 | |||||
Bioclear 2000 | U.S. Well Services, LLC | Anti-Bacterial Agent | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00475 | ||
Deionized Water | 7732-18-5 | 28.00 | 0.00271 | |||||
WFRA-405 | U.S. Well Services, LLC | Friction Reducer | Petroleum Distillates | 64742-47-8 | 22.00 | 0.00961 | ||
Anionic Polyacrylamide | Proprietary | Proprietary | ||||||
Ammonium Chloride | 12125-02-9 | 5.00 | 0.00271 | |||||
Ethoxylated alcohol blend | Proprietary | 5.00 | 0.00271 | |||||
Water | 7732-18-5 | 40.00 | 0.02170 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-04-07 | H2O | 15 | 9689 Bbl | 322120 | US Well Services Inc | STAGE 17
60 SHOTS |
2013-04-07 | H2O | 15 | 8651 Bbl | 283555 | US Well Services Inc | STAGE 15
60 SHOTS |
2013-04-08 | H2O | 15 | 9057 Bbl | 369260 | US Well Services Inc | STAGE 19
60 SHOTS |
2013-04-03 | H2O | 15 | 9598 Bbl | 363320 | US Well Services Inc | STAGE 4
60 SHOTS |
2013-04-05 | H2O | 15 | 9020 Bbl | 368410 | US Well Services Inc | STAGE 10
60 SHOTS |
2013-04-06 | H2O | 15 | 8961 Bbl | 369425 | US Well Services Inc | STAGE 11
60 SHOTS |
2013-04-08 | H2O | 15 | 8870 Bbl | 366580 | US Well Services Inc | STAGE 18
60 SHOTS |
2013-04-09 | H2O | 15 | 8530 Bbl | 352870 | US Well Services Inc | STAGE 25
60 SHOTS |
2013-04-07 | H2O | 15 | 9673 Bbl | 282300 | US Well Services Inc | STAGE 16
60 SHOTS |
2013-04-06 | H2O | 15 | 8853 Bbl | 367300 | US Well Services Inc | STAGE 12
60 SHOTS |
2013-04-09 | H2O | 15 | 8778 Bbl | 369040 | US Well Services Inc | STAGE 24
60 SHOTS |
2013-04-02 | H2O | 15 | 9418 Bbl | 321220 | US Well Services Inc | STAGE 2
60 SHOTS |
2013-04-02 | H2O | 15 | 9100 Bbl | 364810 | US Well Services Inc | STAGE 3
60 SHOTS |
2013-04-07 | H2O | 15 | 8899 Bbl | 369020 | US Well Services Inc | STAGE 14
60 SHOTS |
2013-04-09 | H2O | 15 | 8894 Bbl | 368420 | US Well Services Inc | STAGE 22
60 SHOTS |
2013-04-03 | H2O | 15 | 9043 Bbl | 371720 | US Well Services Inc | STAGE 5
60 SHOTS |
2013-04-01 | H2O | 15 | 10013 Bbl | 79220 | US Well Services Inc | STAGE 1
60 SHOTS |
2013-04-08 | H2O | 15 | 8795 Bbl | 368545 | US Well Services Inc | STAGE 20
60 SHOTS |
2013-04-09 | H2O | 15 | 8815 Bbl | 360900 | US Well Services Inc | STAGE 23
60 SHOTS |
2013-04-04 | H2O | 15 | 9948 Bbl | 272960 | US Well Services Inc | STAGE 6
60 SHOTS |
2013-04-04 | H2O | 15 | 9011 Bbl | 271893 | US Well Services Inc | STAGE 7
60 SHOTS |
2013-04-06 | H2O | 15 | 8908 Bbl | 368430 | US Well Services Inc | STAGE 13
60 SHOTS |
2013-04-05 | H2O | 15 | 9095 Bbl | 356400 | US Well Services Inc | STAGE 9
60 SHOTS |
2013-04-08 | H2O | 15 | 8789 Bbl | 368230 | US Well Services Inc | STAGE 21
60 SHOTS |
2013-04-04 | H2O | 15 | 9907 Bbl | 364950 | US Well Services Inc | STAGE 8
60 SHOTS |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | ANTERO RESOURCES CORPORATION | 452374 | 45446 | 127 |
2014 | ANTERO RESOURCES CORPORATION | 485477 | 39477 | 362 |
2015 | ANTERO RESOURCES CORPORATION | 170714 | 7987 | 365 |
2016 | ANTERO RESOURCES CORPORATION | 168080 | 5294 | 358 |
2017 | ANTERO RESOURCES CORPORATION | 147757 | 3613 | 365 |
2018 | ANTERO RESOURCES CORPORATION | 131775 | 2358 | 365 |
2019 | ANTERO RESOURCES CORPORATION | 27136 | 472 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | ANTERO RESOURCES CORPORATION | Brine | 8186 | 127 |
2014 | ANTERO RESOURCES CORPORATION | Brine | 5344 | 362 |
2015 | ANTERO RESOURCES CORPORATION | Brine | 2050 | 365 |
2016 | ANTERO RESOURCES CORPORATION | Brine | 1557 | 358 |
2017 | ANTERO RESOURCES CORPORATION | Brine | 1278 | 365 |
2018 | ANTERO RESOURCES CORPORATION | Brine | 635 | 365 |
2019 | ANTERO RESOURCES CORPORATION | Brine | 135 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1023643750 | 2013-9-9 0:00:0 | PW | No Violations | 1.00 |
-1562404634 | 2018-6-12 0:00: | PW | No Violations | 0.20 |
-26594235 | 2017-11-7 0:00: | PW | No Violations | |
-35329003 | 2013-9-11 0:00: | PB | No Violations | 1.00 |
-499167331 | 2017-1-11 0:00: | PW | No Violations | 0.50 |
-565116061 | 2012-11-11 0:00 | DD | No Violations | 9.00 |
-655665267 | 2018-11-1 0:00: | PW | No Violations | 0.50 |
-826561782 | 2014-3-31 0:00: | PW | No Violations | 0.30 |
-931504403 | 2013-8-29 0:00: | PW | No Violations | 3.00 |
0026594235 | 2017-11-07 | Production Wells | No Violations | The purpose of my inspection was a status check on a producing well. The pad is named Wayne and there are a total of five wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. The production equipment consists of eight 400 barrel tanks within a lined steel containment, five gas production units within a lined steel containment, one compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current and the identification is located at the wellhead. |
0035329003 | 2013-09-11 | Plug / Plug Back | No Violations | My inspection today finds that all remediation actions have been completed. The soil has been replaced. The area has been reseeded. All sediment controls have been replaced. |
0310040068 | 2012-12-03 | Drill / Deepen / Reopen | No Violations | Stopped by drill site for update they were drilling ahead @6650 cutting lateral they should be at total depth within the next week if all goes well. |
0411050660 | 2012-12-04 | Drill / Deepen / Reopen | No Violations | Stopped at the rig to check progress. The rig is at 6987, and drilling. |
0499167331 | 2017-01-11 | Production Wells | No Violations | The purpose of my inspection today is a status check on a producing well. There are five wells on this pad; 3412124400, 3412124387, 3412124389, 3412124429, and 3412124427. During my inspection the well was equipped with a production tree style wellhead. The production valves are open. The production equipment consists of five gas processing units, eight 400 barrel tanks within containment, and two flare stacks. The production records are current, identification is located on the wellhead, and there are no violations present. |
0565116061 | 2012-11-11 | Drill / Deepen / Reopen | No Violations | My inspection today finds the well operator is having a bond log performed by RWS. After bond logging they determined and I concurred that perforating at 675 would be a good point to perforate and attempt to squeeze cement. Allied attempted to circulate, but the well began to pressure up after 1.5 bbl. And did not circulate. The rig crew is again running the 1 tubing to a depth of 350. Cemented back to surface. A total of 75 sks of cement were used. |
0606387470 | 2017-06-07 | Production Wells | No Violations | The purpose of my inspection was a status check on a producing well. The pad is named Wayne and there are a total of five wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. Gauges present read 340 pounds per square inch on the casing and 160 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consists of eight 400 barrel tanks within a lined steel containment, five gas production units within a lined steel containment, one compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current, the identification is located at the wellhead and gas production unit, and there are no violations present. |
0655665267 | 2018-11-01 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.375-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 450 pounds per square inch, the 9.625-inch diameter casing had 225 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 8 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was midstream equipment on the Northern Corner of the pad. There was secondary containment around the production fluid tanks. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date. |
0700645020 | 2016-03-21 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. |
0826561782 | 2014-03-31 | Production Wells | No Violations | My inspection finds the well appears capable of production. Identification is posted in accordance with 1501.9-9-05(A)10. The tank battery is comprised of twenty 400 bbl tanks located in secondary containment. The tanks are shared by four other wells on the site. The road is well maintained. |
0888863642 | 2014-03-07 | Preliminary Restoration | No Violations | My inspection finds the well site meets the requirements for 1509.072 preliminary restoration. Identification is posted in accordance with 1501.9-9-05(A)10. The tank battery is comprised of twenty 400 bbl tanks located in secondary containment. The road is well maintained. |
0902373149 | 2015-01-29 | Production Wells | No Violations | My inspection today finds the well is produced with a plunger lift system. The tank battery consists of eight 400 barrel tanks set in a liquid tight containment. The production facilities are shared by four other wells on the pad. No violations were noted. |
0931504403 | 2013-08-29 | Production Wells | No Violations | My inspection today finds the spill clean up is progressing. There have been 75 tons of soil removed and hauled to land fill. All heavy oil has been removed. |
1023643750 | 2013-09-09 | Production Wells | No Violations | My inspection today finds the operator is hauling in soil to replace the contaminated soil that was hauled out. |
1352256419 | 2012-11-05 | Drill / Deepen / Reopen | No Violations | I am on site to witness the cementing of the 13.375 casing. The casing string is ran to a depth of 1847. Allied Well Service is on site to pump the cement. At 37 bbl of displacement the pressure jumped to 1600 psi, and continued to climb to 2000 psi. Total cement displaced was 71 bbl. I instructed the company man Delph Martinez to drill out the cement in the pipe, and prepare to find the cement top on the back side of the pipe. |
1352392200 | 2012-11-08 | Drill / Deepen / Reopen | No Violations | I received a call from Delf Martinez of Antero stating that the rig crew had drilled out the cement, and they were ready to pull a bond log. When I arrived the rig crew was having trouble pulling the pipe. RWS wire line services bond logged the well from 1800 to surface. The cement top was at 1160 from surface. The rig crew attempted to run 1 tubing down the back side of the 13.375 tubing to facilitate cementing. The pipe stopped at 350 from surface. |
1352679466 | 2012-11-09 | Drill / Deepen / Reopen | No Violations | I received a call from Delf with Antero, stating that they would be ready to attempt to cement the surface string in an hour. Upon arrival I found the perforators waiting on equipment. I spoke to Delf about their plans. They intended to perforate again and try to squeeze cement again. |
1357872796 | 2012-11-19 | Drill / Deepen / Reopen | No Violations | My inspection today finds the drilling rig at a depth of 4200. |
1377601991 | 2013-08-25 | Production Wells | No Violations | At 5:37 Sam Meyers called and stated that there had been a spill at the site. My inspection found that condensate was released onto the ground outside of containment. The condensate ran down the sites main drainage ditch and appears to have stopped approximately 40 from Opossum Run. Meyers Trucking is onsite to clean and contain. I estimate 5 bbl of contaminate was released. |
1378308091 | 2013-09-03 | Production Wells | No Violations | My inspection today finds the spill clean up is done. The operator will be hauling in clean dirt to replace the soil that was removed. |
1404368977 | 2019-9-13 0:00: | PW | No Violations | 0.50 |
1562404634 | 2018-06-12 | Production Wells | No Violations | The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 260 pounds per square inch, 280 pounds per square inch on the production casing, 0 pounds per square inch on the 9.625 inch diameter intermediate casing, and 0 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of eight 400 barrel tanks, five gas production units, two combustors, and a Triethylene Glycol Dehydration Unit. The Triethylene Glycol Dehydration Unit had an inlet separator, a Glycol contact tower, a horizontal scrubber, and a reboiler. The identification was located at the wellhead. |
1690785011 | 2013-08-26 | Production Wells | No Violations | My inspection today finds the spill has not migrated any further toward the stream. Meyers is onsite to continue cleaning the condensate. Hull Environmental is testing the soil to find the limits of contamination. Ryan Environmental will begin removing soil once the limits have been found. |
2062164990 | 2016-07-13 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. The 9.625 casing head is equipped with a 600 psi gauge and reads 260 psi. |
2130379715 | 2015-04-02 | Production Wells | No Violations | I am accompanied Inspector David Ball today. Our inspection finds the well appears capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. |
310040068 | 2012-12-3 0:00: | DD | No Violations | |
411050660 | 2012-12-4 0:00: | DD | No Violations | 1.00 |
422691971 | 2019-11-27 0:00 | PW | No Violations | 0.50 |
606387470 | 2017-6-7 0:00:0 | PW | No Violations | 0.10 |
700645020 | 2016-3-21 0:00: | PW | No Violations | 1.00 |
846262461 | 2020-7-7 0:00:0 | PW | No Violations | |
888863642 | 2014-3-7 0:00:0 | PL | No Violations | 0.40 |
902373149 | 2015-1-29 0:00: | PW | No Violations | 0.50 |
For data sources see[10]