34-121-24409

Well Details

Well ID: 34-121-24409
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Seneca Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000650
Farm/Lease Name: MILLIGAN UNIT
License Status: Producing
License Date: 2014-06-20
Spud Date: 2013-04-24
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2013-07-08
Well Total Depth: 13809.00 ft
Configuration: Horizontal
Latitude: 39.860000
Longitude: -81.430000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-02-15 Proposed Formations:POINT PLEASANT, Issued Date:2/15/2013, Expired Date:2/15/2015 12:00:00 PM, Drilling unit acres:505.549, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-03-01 CORRECTION TO LEASE NAME.
Reached Total Depth 2013-07-08
Correction to Well 2013-08-30 CORRECTION TO SURFACE AND TARGET INFORMATION (FOOTAGE & X, Y COORDINATES) FROM AS DRILLED SURVEY PLAT.
Correction to Well 2013-11-01 UNIT SIZE CHANGED TO 513.038 ACRES.
Completion Report Received 2014-01-27
APP 2014-06-20 Proposed Formations:POINT PLEASANT, Issued Date:6/20/2014, Expired Date:6/19/2016 12:00:00 PM, Drilling unit acres:513.038, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2016-06-19
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-02-03 7698 13724 0
7698 13724 0
7698 13724 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/17/2013 10/23/2013 7816 7,895,960.0 351993

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AP One U.S. Well Services, LLC Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00105 770
LGC-15 U.S. Well Services, LLC Gelling Agents Surfactant 68439-51-0 3 0.00262 1915.82
Petroleum Distillates 64742-47-8 60 0.04134 30239.8
Suspending agent (solid) 14808-60-7 3 0.00668 4883.45
Guar Gum 9000-30-0 50 0.04365 31930.3
SI-1000 U.S. Well Services, LLC Scale Inhibitor Anionic Copolymer Proprietary 0 0.00462 3382.91
Ethylene Glycol 107-21-1 20 0.00418 3057.88
Water 7732-18-5 30 0.00349 2550.01
AI-300 U.S. Well Services, LLC Acid Corrosion Inhibitors Triethyl Phosphate 78-40-0 3 0.00001000 6.22998
N,N-Dimethylformamide 68-12-2 15 0.00006000 44.2354
Ethylene Glycol 107-21-1 31 0.0002 143.114
Ethoxylated Nonylphenol 68412-54-4 5 0.00001000 10.3833
Cinnamaldehyde 104-55-2 5 0.00005000 38.806
Isopropyl Alcohol 67-63-0 3 0.00001000 4.94771
2-Butoxyethanol 111-76-2 7 0.00005000 33.8145
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.00005000 38.2806
Water 7732-18-5 20 0.00002000 13.1355
K-BAC 1020 U.S. Well Services, LLC Anti-Bacterial Agent 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00456 3331.94
Deionized Water 7732-18-5 28 0.0026 1903.19
HCL Acid (12.6%-18.0%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 87.5 0.07475 54676.5
Hydrogen Chloride 7641-01-1 18 0.01786 13060.4
Water Antero Resources Base Fluid Water 7732-18-5 100 90.031 65,852,300.0
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 9.68592 7,084,680.0
WFRA-405 U.S. Well Services, LLC Friction Reducer Anionic Polyacrylamide Proprietary 0 0.02463 18017.7
Crystalline Salt 12125-02-9 5 0.00308 2252.22
Ethoxylated alcohol blend Proprietary 5 0.00308 2252.22
Petroleum Distillates 64742-47-8 22 0.01983 14504.3
Water 7732-18-5 40 0.02463 18017.7

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-10-17 H2O 15 6623 Bbl 850 US Well Services Inc STAGE 1

60 SHOTS

2013-10-18 H2O 15 6945 Bbl 289090 US Well Services Inc STAGE 5

60 SHOTS

2013-10-21 H2O 15 7482 Bbl 287130 US Well Services Inc STAGE 16

60 SHOTS

2013-10-20 H2O 15 7057 Bbl 288190 US Well Services Inc STAGE 11

60 SHOTS

2013-10-22 H2O 15 7272 Bbl 262190 US Well Services Inc STAGE 22

60 SHOTS

2013-10-20 H2O 15 6885 Bbl 285300 US Well Services Inc STAGE 14

60 SHOTS

2013-10-23 H2O 15 6555 Bbl 281520 US Well Services Inc STAGE 26

60 SHOTS

2013-10-19 H2O 15 6905 Bbl 289260 US Well Services Inc STAGE 10

60 SHOTS

2013-10-18 H2O 15 6907 Bbl 268980 US Well Services Inc STAGE 6

60 SHOTS

2013-10-18 H2O 15 7038 Bbl 287820 US Well Services Inc STAGE 3

60 SHOTS

2013-10-17 H2O 15 7072 Bbl 290640 US Well Services Inc STAGE 2

60 SHOTS

2013-10-21 H2O 15 7526 Bbl 286990 US Well Services Inc STAGE 17

60 SHOTS

2013-10-19 H2O 15 7700 Bbl 268030 US Well Services Inc STAGE 8

60 SHOTS

2013-10-20 H2O 15 6760 Bbl 288250 US Well Services Inc STAGE 15

60 SHOTS

0 0 0
2013-10-18 H2O 15 6977 Bbl 286870 US Well Services Inc STAGE 4

60 SHOTS

2013-10-21 H2O 15 7594 Bbl 287020 US Well Services Inc STAGE 18

60 SHOTS

2013-10-21 H2O 15 6725 Bbl 287590 US Well Services Inc STAGE 19

60 SHOTS

2013-10-23 H2O 15 6679 Bbl 287120 US Well Services Inc STAGE 24

60 SHOTS

2013-10-20 H2O 15 7087 Bbl 213290 US Well Services Inc STAGE 12

60 SHOTS

2013-10-23 H2O 15 6640 Bbl 287010 US Well Services Inc STAGE 25

60 SHOTS

2013-10-23 H2O 15 6630 Bbl 284400 US Well Services Inc STAGE 27

60 SHOTS

2013-10-22 H2O 15 6703 Bbl 287050 US Well Services Inc STAGE 21

60 SHOTS

2013-10-19 H2O 15 6902 Bbl 287950 US Well Services Inc STAGE 9

60 SHOTS

2013-10-22 H2O 15 7260 Bbl 269810 US Well Services Inc STAGE 20

60 SHOTS

2013-10-20 H2O 15 6575 Bbl 240920 US Well Services Inc STAGE 13

60 SHOTS

2013-10-23 H2O 15 6747 Bbl 288820 US Well Services Inc STAGE 23

60 SHOTS

2013-10-19 H2O 15 6753 Bbl 102585 US Well Services Inc STAGE 7

60 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 ANTERO RESOURCES CORPORATION 0 880 0
2014 ANTERO RESOURCES CORPORATION 716708 62022 348
2015 ANTERO RESOURCES CORPORATION 251136 13372 364
2016 ANTERO RESOURCES CORPORATION 187865 10712 359
2017 ANTERO RESOURCES CORPORATION 146173 5527 365
2018 ANTERO RESOURCES CORPORATION 121939 3704 340
2019 ANTERO RESOURCES CORPORATION 28573 946 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 ANTERO RESOURCES CORPORATION Brine 0 0
2014 ANTERO RESOURCES CORPORATION Brine 7764 348
2015 ANTERO RESOURCES CORPORATION Brine 6484 364
2016 ANTERO RESOURCES CORPORATION Brine 2108 359
2017 ANTERO RESOURCES CORPORATION Brine 1424 365
2018 ANTERO RESOURCES CORPORATION Brine 791 340
2019 ANTERO RESOURCES CORPORATION Brine 223 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1025027733 2018-6-12 0:00: PW No Violations 0.20
-1145363041 2016-3-21 0:00: PW No Violations 1.00
-1212271577 2014-1-28 0:00: PL No Violations 1.00
-12947543 2017-11-7 0:00: PW No Violations 0.50
-133634714 2013-6-26 0:00: DD No Violations 2.50
-1658479373 2017-6-7 0:00:0 PW No Violations 0.10
-1678703212 2018-11-1 0:00: PW No Violations 0.50
-1680264343 2014-3-31 0:00: PW No Violations 0.40
-1906748746 2015-4-2 0:00:0 PL No Violations 0.20
-1923670241 2013-11-21 0:00 CT No Violations
-2017153861 2019-11-27 0:00 PW No Violations 0.50
0012947543 2017-11-07 Production Wells No Violations The purpose of my inspection was a status check on a production well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. The production equipment consisted of eighteen 400 barrel tanks within a lined steel containment, six gas production units within a lined steel containment, one vent scrubber, two compressors, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current and the identification was located at the wellhead.
0133634714 2013-06-26 Drill / Deepen / Reopen No Violations My inspection today finds the well was struck by lightning at 7:00 pm last night. The lightning burnt out a module in the top drive. The top drive has been repaired and the rig is currently drilling at a depth of 6350. A review of the site indicates that the operator can remove the super silt fence around the location.
1025027733 2018-06-12 Production Wells No Violations The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 202 pounds per square inch, 370 pounds per square inch on the production casing, 0 pounds per square inch on the 9.625 inch diameter intermediate casing, and 170 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of eighteen 400 barrel tanks, six gas production units, and two combustors. The identification was located at the wellhead.
1145363041 2016-03-21 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production with a tubing plunger lift system. The tank battery is comprised of eighteen 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds six production units. The production equipment is shared with five other wells on the pad.
1212271577 2014-01-28 Preliminary Restoration No Violations My inspection finds the preliminary restoration requirements have been met. The tank battery consists of eighteen 400 bbl tanks that are shared with three other wells.
1411378611 2013-06-24 Drill / Deepen / Reopen No Violations My inspection today finds Patterson is drilling at a depth of 5149.
1456236498 2013-07-01 Drill / Deepen / Reopen No Violations My inspection today finds the rig (Patterson 343) is drilling 8.5 hole at a depth of 7020 building the curve section of the well.
1458879711 2013-06-11 Casing String Witnessed No Violations I am onsite to witness surface casing cementing operations. Patterson rig 343 ran 565 of 18.625 casing. Superior Well Service cemented the casing in place with 470 bbl of class A cement. 176 bbl of cement circulated to surface.
1475985360 2013-06-19 Production Wells No Violations My inspection today finds that the drilling rig is currently drilling 12.25 hole at a depth of 2411. I reviewed the BOP test results.
1563560518 2017-01-11 Production Wells No Violations The purpose of my inspection today is a status check on a producing well. There are six wells on this pad; 3412124408, 3412124409, 3412124407, 3412124471, 3412124472, and 3412124428. During my inspection the well was equipped with a production tree style wellhead. The production valves are open. The production equipment consists of six gas processing units, eighteen 400 barrel tanks within containment, and two flare stacks. The production records are current, identification is located on the wellhead, and there are no violations present.
1652983689 2013-06-11 Drill / Deepen / Reopen No Violations My inspection today finds that the rig has drilled a 24 hole to a depth of 565. They are preparing to run 560 of 18.625 casing.
1658479373 2017-06-07 Production Wells No Violations The purpose of my inspection was a status check on a producing well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. Gauges present read 285 pounds per square inch on the casing and 209 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consists of eighteen 400 barrel tanks within a lined steel containment, six gas processing units within a lined steel containment, two compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current, the identification was located at the wellhead and gas production unit, and there were no violations present.
1678703212 2018-11-01 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 150 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 6- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. There was a small gas leak below the B section of the well head, I contacted Zac Cornish an Environmental Technician with Antero and made him aware of the problem. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date.
1680264343 2014-03-31 Production Wells No Violations My inspection finds well is in production. The tank battery consists of eighteen 400 bbl tanks that are shared with three other wells. The identification is posted as required. The well site is being prepared for a drilling rig.
1906748746 2015-04-02 Preliminary Restoration No Violations I am accompanied Inspector David Ball today. Our inspection finds the well appears capable of production with the production valves open. The tank battery is comprised of eighteen 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. The well site meets the preliminary restoration requirements.
1923670241 2013-11-21 Completion Testing No Violations My inspection today finds the service rig has drilled out the kill plug at 5001 and is running tubing to the first plug.
1985738344 2019-9-13 0:00: PW No Violations 0.50

For data sources see[10]