Well Details

Well ID: 34-121-24427
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Seneca Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000520
Farm/Lease Name: SCHEETZ UNIT
License Status: Producing
License Date: 2013-06-10
Spud Date: 2013-10-01
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2013-12-01
Well Total Depth: 16046.00 ft
Configuration: Horizontal
Latitude: 39.860000
Longitude: -81.420000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-06-10 Proposed Formations:POINT PLEASANT, Issued Date:6/10/2013, Expired Date:6/10/2015 12:00:00 PM, Drilling unit acres:640, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2013-12-01
Correction to Well 2013-12-06 CHANGE IN PROPOSED TOTAL DEPTH.
Correction to Well 2014-01-03 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 428.049 ACRES.
Completion Report Received 2014-05-27
Construction Permit Expires 2015-06-10
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-06-12 10000 15956 0
10000 15956 0
10000 15956 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 01/10/2014 01/21/2014 7402 8,946,880.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Plexaid 673 Chemplex Scale Inhibitor Methyl Alcohol 67-56-1 25 0.00393 0
Water 7732-18-5 85 0.01335 0
Sodium Salt of Phosphonodimethylated Diamine Proprietary 5 0.00079 0
Freshwater Antero Resources Water Water 7732-18-5 100 90.709 0
Plexcide 15G Chemplex Biocide Water 7732-18-5 90 0.02285 0
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.00076 0
Glutaraldehyde 111-30-8 14 0.00355 0
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.00076 0
Ethanol 64-17-5 3 0.00076 0
40/70 White US Silica Propppant Sand 14808-60-7 100 4.9144 0
Beta M-4.0 PQS Guar Gel Clay 1302-78-9 5 0.00425 0
Guar Gum 9000-30-0 50 0.04252 0
Petroleum Distillate 64742-47-8 55 0.04677 0
Surfactant 154518-36-2 1 0.00085 0
20/40 White US Silica Propppant Sand 14808-60-7 100 2.9237 0
Hydrochloric Acid 10-15% Reagent Acid Hydrchloric Acid 7647-01-0 15 0.03424 0
Plexslick 953 Chemplex Friction Reducer Alcohol Ethoxylate Surfactants Proprietary 8 0.00492 0
Hydrotreated Petroleum Distillate 64742-47-8 30 0.01844 0
Water 7732-18-5 35 0.02152 0
Polyacrylamide-co-acrylic acid 9003-06-9 32 0.01967 0
Sodium Persulfate Chemplex Breaker Sodium Persulfate 7775-27-1 100 0.00123 0
100 Mesh US Silica Propppant Sand 14808-60-7 100 1.2677 0
Plexhib 256 Chemplex Corrosion n-olefins Proprietary 10 0.00007000 0
Alcohol Ethoxylate Surfactants Proprietary 30 0.00021 0
Methyl Alcohol 67-56-1 70 0.00049 0
thiourea-formaldehyde copolymer 68527-49-1 30 0.00021 0
Propargyl Alcohol 107-19-7 8 0.00006000 0
Plexbreak 145 Chemplex Non-emulsifier Water 732-18-5 66 0.00052 0
Ethylene Glycol Monobutyl Ether 111-76-2 15 0.00012 0
Diethanolamine 111-42-2 5 0.00004000 0
Cocamide Diethanolamine Salt 68603-42-9 10 0.00008000 0
Methyl Alcohol 67-56-1 15 0.00012 0
Ferriplex 66 Chemplex Iron Control Water 7732-18-5 35 0.00016 0
Acetic Acid 64-19-7 50 0.00022 0
Citric Acid 77-92-9 30 0.00013 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-01-17 H2O 15 3842 Bbl 143693 Go Frac LLC STAGE 22

60 SHOTS

2014-01-19 H2O 15 5080 Bbl 239778 Go Frac LLC STAGE 28

60 SHOTS

2014-01-14 H2O 15 4350 Bbl 238944 Go Frac LLC STAGE 11

60 SHOTS

2014-01-13 H2O 15 4377 Bbl 243052 Go Frac LLC STAGE 10

60 SHOTS

2014-01-20 H2O 15 4864 Bbl 243537 Go Frac LLC STAGE 31

60 SHOTS

2014-01-15 H2O 15 4434 Bbl 243570 Go Frac LLC STAGE 15

60 SHOTS

2014-01-12 H2O 15 4401 Bbl 242282 Go Frac LLC STAGE 6

60 SHOTS

2014-01-12 H2O 15 4349 Bbl 235104 Go Frac LLC STAGE 7

60 SHOTS

2014-01-16 H2O 15 4534 Bbl 241543 Go Frac LLC STAGE 21

60 SHOTS

2014-01-20 H2O 15 4351 Bbl 244150 Go Frac LLC STAGE 32

60 SHOTS

2014-01-13 H2O 15 4437 Bbl 239828 Go Frac LLC STAGE 8

60 SHOTS

2014-01-14 H2O 15 4419 Bbl 241724 Go Frac LLC STAGE 14

60 SHOTS

2014-01-14 H2O 15 4408 Bbl 242607 Go Frac LLC STAGE 13

60 SHOTS

2014-01-17 H2O 15 4507 Bbl 243311 Go Frac LLC STAGE 25

60 SHOTS

2014-01-15 H2O 15 4511 Bbl 241602 Go Frac LLC STAGE 18

60 SHOTS

2014-01-15 H2O 15 4593 Bbl 262676 Go Frac LLC STAGE 17

60 SHOTS

2014-01-20 H2O 15 4428 Bbl 244381 Go Frac LLC STAGE 29

60 SHOTS

2014-01-17 H2O 15 4478 Bbl 183502 Go Frac LLC STAGE 23

60 SHOTS

2014-01-16 H2O 15 4526 Bbl 242661 Go Frac LLC STAGE 20

60 SHOTS

2014-01-12 H2O 15 4465 Bbl 243127 Go Frac LLC STAGE 4

60 SHOTS

2014-01-14 H2O 15 4384 Bbl 242416 Go Frac LLC STAGE 12

60 SHOTS

2014-01-19 H2O 15 4486 Bbl 245382 Go Frac LLC STAGE 27

60 SHOTS

2014-01-19 H2O 15 4472 Bbl 241699 Go Frac LLC STAGE 26

60 SHOTS

2014-01-21 H2O 15 4363 Bbl 244437 Go Frac LLC STAGE 33

60 SHOTS

2014-01-17 H2O 15 4473 Bbl 241902 Go Frac LLC STAGE 24

60 SHOTS

2014-01-16 H2O 15 4172 Bbl 194268 Go Frac LLC STAGE 19

60 SHOTS

2014-01-11 H2O 15 3866 Bbl 170460 Go Frac LLC STAGE 3

60 SHOTS

2014-01-20 H2O 15 4852 Bbl 230896 Go Frac LLC STAGE 30

60 SHOTS

2014-01-10 H2O 15 3924 Bbl 241325 Go Frac LLC STAGE 1

60 SHOTS

2014-01-12 H2O 15 4175 Bbl 184402 Go Frac LLC STAGE 5

60 SHOTS

2014-01-21 H2O 15 4656 Bbl 219530 Go Frac LLC STAGE 34

60 SHOTS

2014-01-11 H2O 15 6172 Bbl 242264 Go Frac LLC STAGE 2

60 SHOTS

2014-01-15 H2O 15 4390 Bbl 244124 Go Frac LLC STAGE 16

60 SHOTS

2014-01-13 H2O 15 4360 Bbl 241960 Go Frac LLC STAGE 9

60 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 ANTERO RESOURCES CORPORATION 759989 73399 309
2015 ANTERO RESOURCES CORPORATION 298729 21167 364
2016 ANTERO RESOURCES CORPORATION 204155 10739 326
2017 ANTERO RESOURCES CORPORATION 174239 9236 363
2018 ANTERO RESOURCES CORPORATION 118252 8815 344
2019 ANTERO RESOURCES CORPORATION 26660 1979 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 ANTERO RESOURCES CORPORATION Brine 27037 309
2015 ANTERO RESOURCES CORPORATION Brine 3615 364
2016 ANTERO RESOURCES CORPORATION Brine 1931 326
2017 ANTERO RESOURCES CORPORATION Brine 1835 363
2018 ANTERO RESOURCES CORPORATION Brine 2350 344
2019 ANTERO RESOURCES CORPORATION Brine 429 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1317197109 2013-10-10 0:00 DD No Violations 1.00
-1318523816 2017-1-11 0:00: PW No Violations 0.10
-1504067592 2020-7-7 0:00:0 PW No Violations 0.30
-1579191763 2016-7-14 0:00: PW No Violations 0.50
-1642404589 2013-12-10 0:00 DD No Violations 2.00
-1826724708 2019-9-13 0:00: PW No Violations 0.50
-259719860 2013-10-2 0:00: CS No Violations 2.00
-370474653 2016-3-21 0:00: PW No Violations 0.50
-729544416 2017-11-7 0:00: PW No Violations 0.50
-864035787 2018-6-12 0:00: PW No Violations 0.20
0088555133 2017-06-07 Production Wells No Violations The purpose of my inspection was a status check on a producing well. The pad is named Wayne and there are a total of five wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. Gauges present read 380 pounds per square inch on the casing and 180 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consists of eight 400 barrel tanks within a lined steel containment, five gas production units within a lined steel containment, one compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current, the identification is located at the wellhead and gas production unit, and there are no violations present.
0258043049 2014-03-31 Production Wells No Violations My inspection finds the well appears capable of production. Identification is posted in accordance with 1501.9-9-05(A)10. The tank battery is comprised of twenty 400 bbl tanks located in secondary containment. The tanks are shared by four other wells on the site. The road is well maintained.
0259719860 2013-10-02 Casing String Witnessed No Violations My inspection today finds Express ran 100 of 26 casing. Allied cemented the casing in place with 60 bbl of class A cement. Good returns to surface.
0370474653 2016-03-21 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad.
0410296972 2014-03-07 Preliminary Restoration No Violations My inspection finds the well site meets the requirements for 1509.072 preliminary restoration. Identification is posted in accordance with 1501.9-9-05(A)10. The tank battery is comprised of twenty 400 bbl tanks located in secondary containment.
0729544416 2017-11-07 Production Wells No Violations The purpose of my inspection was a status check on a producing well. The pad is named Wayne and there are a total of five wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. The production equipment consists of eight 400 barrel tanks within a lined steel containment, five gas production units within a lined steel containment, one compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current and the identification is located at the wellhead.
0864035787 2018-06-12 Production Wells No Violations The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 165 pounds per square inch, 320 pounds per square inch on the production casing, 0 pounds per square inch on the 9.625 inch diameter intermediate casing, and 0 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of eight 400 barrel tanks, five gas production units, two combustors, and a Triethylene Glycol Dehydration Unit. The Triethylene Glycol Dehydration Unit had an inlet separator, a Glycol contact tower, a horizontal scrubber, and a reboiler. The identification was located at the wellhead.
1111373064 2018-11-01 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.375-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 100 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 8 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was midstream equipment on the Northern Corner of the pad. There was secondary containment around the production fluid tanks. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date.
1317197109 2013-10-10 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is at a depth of 179. The top drive on the rig is broke down.
1318523816 2017-01-11 Production Wells No Violations The purpose of my inspection today is a status check on a producing well. There are five wells on this pad; 3412124400, 3412124387, 3412124389, 3412124429, and 3412124427. During my inspection the well was equipped with a production tree style wellhead. The production valves are open. The production equipment consists of five gas processing units, eight 400 barrel tanks within containment, and two flare stacks. The production records are current, identification is located on the wellhead, and there are no violations present.
1384783441 2013-11-18 Drill / Deepen / Reopen No Violations My inspection today finds the cement job on the 9.625 lost circulation at 340 bbl of 520 bbl total displacement. A bond log will be performed to determine the cement top.
1385134033 2013-11-11 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is currently drilling a 12.25 hole at a depth of 2894. I asked the company man to install jersey barriers around the production facilities.
1413406749 2013-11-18 Drill / Deepen / Reopen No Violations My inspection today finds the cement top on the 9.625 casing is at 2150. The cement appears to adequate to isolate potential flow zones.
1517493116 2015-04-02 Production Wells No Violations I am accompanied Inspector David Ball today. Our inspection finds the well appears capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad.
1579191763 2016-07-14 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production with the production valves open. The tank battery is comprised of eight 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. The 9.625 casing head is equipped with a 600 psi gauge and reads 590 psi.
1618427257 2013-12-16 Drill / Deepen / Reopen No Violations The rig is preparing to move. I am onsite to ensure that the producing wells are shut in during the rig move.
1642404589 2013-12-10 Drill / Deepen / Reopen No Violations My inspection today finds Patterson Drilling is drilling an 8.5 hole at a depth of 13856. I have asked the company to review their electrical grounding practices.
1666371859 2013-11-05 Casing String Witnessed No Violations My inspection today finds the rig ran 370 of 18.625 casing. Allied circulated 730 sks of class A cement into place. 50 bbl cement returns to surface.
1832558999 2013-11-07 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is drilling 17.5 hole at a depth of 1638. There is a significant amount of rain water accumulated on site.
1862032708 2015-01-29 Production Wells No Violations My inspection today finds the well is produced with a plunger lift system. The tank battery consists of eight 400 barrel tanks set in a liquid tight containment. The production facilities are shared by four other wells on the pad. No violations were noted.
258043049 2014-3-31 0:00: PW No Violations 0.30
410296972 2014-3-7 0:00:0 PL No Violations
705399414 2019-11-27 0:00 PW No Violations 0.50
88555133 2017-6-7 0:00:0 PW No Violations 0.10

For data sources see[10]

References