34-121-24436

Well Details

Well ID: 34-121-24436
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Beaver Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000626
Farm/Lease Name: DOLLISON UNIT
License Status: Producing
License Date: 2013-07-08
Spud Date: 2013-08-27
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2013-12-04
Well Total Depth: 14336.00 ft
Configuration: Horizontal
Latitude: 39.910000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-08 Proposed Formations:POINT PLEASANT, Issued Date:7/8/2013, Expired Date:7/8/2015 12:00:00 PM, Drilling unit acres:698.234, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-08-16 CHANGE IN PROPOSED TOTAL DEPTH.
Correction to Well 2013-11-01 CORRECTION TO TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 634.335 ACRES. SPACING VARIANCE GRANTED.
Reached Total Depth 2013-12-04
Correction to Well 2014-01-17 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. QUAD CHANGED TO QUAKER CITY.
Completion Report Received 2014-10-27
Construction Permit Expires 2015-07-08
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-11-03 8140 14184 0
8140 14184 0
8140 14184 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/14/2014 02/24/2014 7744 9,400,270.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 100 Mesh US Silica Propppant Sand 14808-60-7 100 1.2677 0
20/40 White US Silica Propppant Sand 14808-60-7 100 2.9237 0
Beta M-4.0 PfP Guar Gel Guar Gum 9000-30-0 50 0.04252 0
Surfactant 154518-36-2 1 0.00085 0
Petroleum Distillate 64742-47-8 55 0.04677 0
Clay 1302-78-9 5 0.00425 0
Plexaid 673 Chemplex Scale Inhibitor Methyl Alcohol 67-56-1 25 0.00393 0
Sodium Salt of Phosphonodimethylated Diamine Proprietary 5 0.00079 0
Water 7732-18-5 85 0.01335 0
Ferriplex 66 Chemplex Iron Control Acetic Acid 64-19-7 50 0.00022 0
Water 7732-18-5 35 0.00016 0
Citric Acid 77-92-9 30 0.00013 0
Plexcide 15G Chemplex Biocide Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.00076 0
Ethanol 64-17-5 3 0.00076 0
Glutaraldehyde 111-30-8 14 0.00355 0
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.00076 0
Water 7732-18-5 90 0.02285 0
Sodium Persulfate Chemplex Breaker Sodium Persulfate 7775-27-1 100 0.00123 0
Plexhib 256 Chemplex Corrosion thiourea-formaldehyde copolymer 68527-49-1 30 0.00021 0
Alcohol Ethoxylate Surfactants Proprietary 30 0.00021 0
Propargyl Alcohol 107-19-7 8 0.00006000 0
n-olefins Proprietary 10 0.00007000 0
Methyl Alcohol 67-56-1 70 0.00049 0
40/70 White US Silica Propppant Sand 14808-60-7 100 4.9144 0
Plexslick 953 Chemplex Friction Reducer Alcohol Ethoxylate Surfactants Proprietary 8 0.00492 0
Hydrotreated Petroleum Distillate 64742-47-8 30 0.01844 0
Polyacrylamide-co-acrylic acid 9003-06-9 32 0.01967 0
Water 7732-18-5 35 0.02152 0
Freshwater Antero Resources Water Water 7732-18-5 100 90.709 0
Plexbreak 145 Chemplex Non-emulsifier Diethanolamine 111-42-2 5 0.00004000 0
Methyl Alcohol 67-56-1 15 0.00012 0
Ethylene Glycol Monobutyl Ether 111-76-2 15 0.00012 0
Water 732-18-5 66 0.00052 0
Cocamide Diethanolamine Salt 68603-42-9 10 0.00008000 0
Hydrochloric Acid 10-15% Reagent Acid Hydrchloric Acid 7647-01-0 15 0.03424 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-02-24 H2O 15 4464 Bbl 239649 Go Frac LLC STAGE 35/35
2014-02-14 H2O 15 4221 Bbl 228065 Go Frac LLC STAGE 1/35

STAGES 2-34 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 ANTERO RESOURCES CORPORATION 1205276 36037 271
2015 ANTERO RESOURCES CORPORATION 1044793 13641 365
2016 ANTERO RESOURCES CORPORATION 513260 4893 361
2017 ANTERO RESOURCES CORPORATION 361312 2489 365
2018 ANTERO RESOURCES CORPORATION 230056 573 333
2019 ANTERO RESOURCES CORPORATION 53623 145 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 ANTERO RESOURCES CORPORATION Brine 5351 271
2015 ANTERO RESOURCES CORPORATION Brine 17715 365
2016 ANTERO RESOURCES CORPORATION Brine 5063 361
2017 ANTERO RESOURCES CORPORATION Brine 3289 365
2018 ANTERO RESOURCES CORPORATION Brine 1141 333
2019 ANTERO RESOURCES CORPORATION Brine 402 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1486321491 2013-10-21 0:00 CS No Violations 4.00
-1730508642 2014-5-16 0:00: PW No Violations 0.10
-1798438408 2018-6-12 0:00: PW No Violations 0.20
-1909323711 2018-3-5 0:00:0 PW No Violations 0.20
-610280216 2018-3-8 0:00:0 PW No Violations 0.20
-683636919 2017-1-20 0:00: PW No Violations 0.50
-767192811 2013-8-28 0:00: CS No Violations 3.00
-836444505 2018-4-20 0:00: PW No Violations 0.20
-962093222 2015-6-16 0:00: PW No Violations 0.20
-994101880 2014-4-30 0:00: PW No Violations 0.10
0574541030 2015-02-11 Preliminary Restoration No Violations My inspection today finds the well site meets the preliminary restoration requirements. The tank battery is comprised of eight 500 barrel tanks set inside a liquid tight plastic liner.
0610280216 2018-03-08 Production Wells No Violations The purpose of my inspection was a status check on a cut slope slip failure. The pad name is Roe and there are a total of 7 wells. The slip occurred in the cut slope of the pad in the Northwest corner where the eight 400 barrel tanks and two vapor recovery towers were located. That equipment had been removed in order for Antero to take remedial action on the slope failure. The remaining production equipment and wellheads were outside the area of concern. ODNR Division of Oil and Gas Engineering Section is currently working with Antero Resources with planning the material modification to repair the slope.
0683636919 2017-01-20 Production Wells No Violations The purpose of my inspection is a status check on a producing well. The pad name is Roe and there are a total of 7 wells on this pad. During my inspection the well was equipped with a production tree style wellhead. The production equipment for this well consists of eight 400 barrel tanks within containment, and seven gas processing units. The vapor recovery system consists of two compressors and three Cimarron combustors. The production records are current, the identification is located at the wellhead, and there are no violations present.
0767192811 2013-08-28 Casing String Witnessed No Violations On site to witness cementing of conductor casing, Allied cementing pumped336 sacks of cement and they had good returns and they left 2.5 inside of bottom of cellar to ensure that there will be no ground water contamination.
0836444505 2018-04-20 Production Wells No Violations During my inspection contractors for Antero Resources were on location running lines to the combustors. The production equipment had been relocated due to a slip near the old orientation of the production equipment on the north side of the pad.
0962093222 2015-06-16 Production Wells No Violations The well is equipped in a manner consistent with being capable of production. All drainage sumps on the location are closed. No violations were noted during the inspection.
0994101880 2014-04-30 Production Wells No Violations My inspection finds the diesel spill that took place during the completion phase is still causing some sheen on top of the water in the sump. The company is hauling all water off site to be disposed of or recycled. I have asked the company to remove all contaminated stone and soil. The tank battery is comprised of eight 400 bbl tanks set in a containment system.
0994415861 2018-07-16 Production Wells No Violations The purpose of my inspection today was to witness Antero re-assembling the Grissom 1H plunger lift system. The well was equipped with a plunger lift system with valves in the open position. A pressure gauge was present on all casing strings. Accompanied by Antero Production Superintendent during my inspection.
1078012218 2013-11-27 Drill / Deepen / Reopen No Violations My inspection today finds the rig has completed the BOP pressure test. They are running drill pipe in the hole to begin drilling the 8.5 section.
1129304378 2020-4-28 0:00: PW No Violations 0.20
1171915293 2013-12-03 Casing String Witnessed No Violations My inspection today finds the drilling rig is running 5.5 casing at a depth of 7888. Allied will be cementing the casing in place later tonight.
1280317832 2018-03-21 Production Wells No Violations The purpose of my inspection was a status check. The pad is named Roe and there are a total of 7 wells. During my inspection construction equipment was on location to make repairs to the slips located on the cut slope and fill slopes of the pad. Antero is actively working with ODNR Division of Oil and Gas Engineering section to make necessary slip repairs. The slips do not oppose any threat to the wells and the wells are under continuous pressure monitoring.
1383316000 2013-10-31 Drill / Deepen / Reopen No Violations My inspection today finds Patterson Drilling rig 342 is currently drilling 12.25 hole at 6352.
140328265 2019-10-10 0:00 PW No Violations 0.50
1486321491 2013-10-21 Casing String Witnessed No Violations My inspection today finds the drilling rig, Patterson 342, ran 388 of 18.625 casing. Allied cemented the casing in place with class A cement.
1630127591 2017-05-09 Production Wells No Violations The purpose of my inspection was a status check on a producing well. The pad is named Roe and there are a total of 7 wells on this pad. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges present read 310 pounds per square inch on the casing and 170 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment for this well consists of eight 400 barrel tanks, seven gas processing units, two compressors, and two Cimarron combustors. The pipeline tie in is located on the west side of the pad. The production records are current, the identification is located at the wellhead, and there are no violations present.
1710542102 2013-10-21 Drill / Deepen / Reopen No Violations My inspection today finds the rig has drilled to 380 and is preparing to pull the drill pipe. The permits are posted and safety equipment is present.
1730508642 2014-05-16 Production Wells No Violations The well is equipped to be capable of production. The well is produced into eight 400 bbl tanks set in liquid tight containment. The GPS data was updated to enhance accuracy.
1798438408 2018-06-12 Production Wells No Violations Prior inspection found contractors for Antero relocating and reassembling production equipment due to a slip in the cut slope of the North side if the pad. During my inspection today, the tank battery had been moved and reset within steel containment and the vapor recovery system had been connected. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 566 pounds per square inch, 613 pounds per square inch on the production casing, 470 pounds per square inch on the 9.625 inch diameter intermediate casing, and 150 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of four 400 barrel tanks, seven gas production units, and two combustors. The identification was located at the wellhead.
1909323711 2018-03-05 Production Wells No Violations
574541030 2015-2-11 0:00: PL No Violations
994415861 2018-7-16 0:00: PW No Violations 0.10

For data sources see[10]