If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-24471 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.86,"lon":-81.43,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Seneca Township | |
Operator Name: ANTERO RESOURCES CORPORATION | |
Well Pad ID: US-OH-000650 | |
Farm/Lease Name: NEUHART WEST UNIT | |
License Status: Producing | |
License Date: 2014-09-29 | |
Spud Date: 2014-02-20 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2014-12-12 | |
Well Total Depth: 16990.00 ft | |
Configuration: Horizontal | |
Latitude: 39.860000 | |
Longitude: -81.430000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-01-23 | Proposed Formations:POINT PLEASANT, Issued Date:1/23/2014, Expired Date:1/23/2016 12:00:00 PM, Drilling unit acres:586.617, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2014-04-25 | CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
APP | 2014-09-29 | Proposed Formations:POINT PLEASANT, Issued Date:9/29/2014, Expired Date:9/28/2016 12:00:00 PM, Drilling unit acres:381.987, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-12-12 | |
Correction to Well | 2015-01-23 | CHANGE IN SURFACE, TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORINDATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE INCREASED. |
Completion Report Received | 2015-05-13 | |
Construction Permit Expires | 2016-09-28 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2015-05-13 | 8723 | 16908 | 0 |
8723 | 16908 | 0 | |
8723 | 16908 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 01/02/2015 | 01/19/2015 | 7722 | 12,437,500.0 | 578501 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SI-1100 | U.S. Well Services | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 40 | 0.0058 | 6679.87 |
2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00165 | 1906.42 | ||||
Acrylic polymer | 52255-49-9 | 5 | 0.00064 | 738.924 | ||||
bis (hexamethylene) tramine penta
(methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.00148 | 1699.53 | ||||
Di Water | 7732-18-5 | 80 | 0.01026 | 11822.8 | ||||
Potassium salt of diethylene triamine
penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.00173 | 1995.09 | ||||
Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00151 | 1743.86 | ||||
hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.0016 | 1847.31 | ||||
LGC-15 | U.S. Well Services | Gelling Agents | Petroleum Distillates | 64742-47-8 | 60 | 0.0343 | 39512.8 | |
Suspending agent (solid) | 14808-60-7 | 3 | 0.00554 | 6380.95 | ||||
Surfactant | 68439-51-0 | 3 | 0.00217 | 2503.3 | ||||
Guar Gum | 9000-30-0 | 50 | 0.03621 | 41721.6 | ||||
HCL Acid (12.6%-18.0%) | U.S. Well Services | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 18 | 0.07694 | 88636.9 | |
Water | 7732-18-5 | 87.5 | 0.32209 | 371071 | ||||
Sand | U.S. Well Services | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 9.37344 | 10,798,800.0 | |
AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Coco amine | 61791-14-8 | 5 | 0.00003000 | 39.1313 | |
Polyethylene polyamine | 68603-67-8 | 10 | 0.00007000 | 85.6635 | ||||
Diethylene Glycol | 111-46-6 | 30 | 0.00025 | 285.573 | ||||
Methenamine | 100-97-0 | 20 | 0.0002 | 226.281 | ||||
Hydrogen Chloride | 7647-01-0 | 10 | 0.00009000 | 98.6789 | ||||
K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.0039 | 4488.92 | |
Deionized Water | 7732-18-5 | 28 | 0.00223 | 2564.05 | ||||
AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00157 | 1805 | |
Water | Antero Resources | Base Fluid | Water | 7732-18-5 | 100 | 90.0374 | 103,729,000.0 | |
WFRA-405 | U.S. Well Services | Friction Reducer | Petroleum Distillates | 64742-47-8 | 40 | 0.0208 | 23962.5 | |
Crystalline Salt | 12125-02-9 | 5 | 0.00323 | 3720.89 | ||||
Anionic Polyacrylamide | Proprietary | 40 | 0.02584 | 29767.1 | ||||
Ethoxylated alcohol blend | Proprietary | 5 | 0.00323 | 3720.89 | ||||
Water | 7732-18-5 | 40 | 0.02584 | 29767.1 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-01-02 | H2O | 15 | 6147 Bbl | 236925 | US Well Services Inc | STAGE 1/47
60 SHOTS STAGES 2-46 SEE IMAGES |
2020-01-19 | H2O | 1 | 5594 Bbl | 235000 | US Well Services Inc | STAGE 47/47
60 SHOTS |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | 725836 | 77920 | 306 |
2016 | ANTERO RESOURCES CORPORATION | 360955 | 31641 | 359 |
2017 | ANTERO RESOURCES CORPORATION | 222552 | 17267 | 365 |
2018 | ANTERO RESOURCES CORPORATION | 159637 | 13922 | 341 |
2019 | ANTERO RESOURCES CORPORATION | 40027 | 3334 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | Brine | 23425 | 306 |
2016 | ANTERO RESOURCES CORPORATION | Brine | 4078 | 359 |
2017 | ANTERO RESOURCES CORPORATION | Brine | 2505 | 365 |
2018 | ANTERO RESOURCES CORPORATION | Brine | 2392 | 341 |
2019 | ANTERO RESOURCES CORPORATION | Brine | 771 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1036891940 | 2014-12-9 0:00: | CS | No Violations | |
-205244327 | 2017-6-7 0:00:0 | PW | No Violations | 0.10 |
-2115233097 | 2014-2-21 0:00: | CS | No Violations | 3.50 |
-614690860 | 2015-4-2 0:00:0 | PL | No Violations | 0.30 |
-653810785 | 2019-9-13 0:00: | PW | No Violations | 0.50 |
-738320155 | 2016-3-21 0:00: | PW | No Violations | 0.50 |
0201810431 | 2017-11-07 | Production Wells | No Violations | The purpose of my inspection was a status check on a production well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. The production equipment consisted of eighteen 400 barrel tanks within a lined steel containment, six gas production units within a lined steel containment, one vent scrubber, two compressors, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current and the identification was located at the wellhead. |
0205244327 | 2017-06-07 | Production Wells | No Violations | The purpose of my inspection was a status check on a producing well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. Gauges present read 420 pounds per square inch on the casing and 230 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consists of eighteen 400 barrel tanks within a lined steel containment, six gas processing units within a lined steel containment, two compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current, the identification was located at the wellhead and gas production unit, and there were no violations present. |
0354725626 | 2014-03-10 | Drill / Deepen / Reopen | No Violations | I stopped at the rig to pick up the cement tickets for the surface string. I called Darren Rader with Antero and asked him to remove accumulated trash from the perimeter of the site. |
0614544866 | 2018-11-01 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 380 pounds per square inch, the 9.625-inch diameter casing had 420 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 6- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date. |
0614690860 | 2015-04-02 | Preliminary Restoration | No Violations | I am accompanied Inspector David Ball today. Our inspection finds the well appears capable of production with the production valves open. The tank battery is comprised of eighteen 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. The well site meets the preliminary restoration requirements. |
0648040932 | 2017-01-11 | Production Wells | No Violations | The purpose of my inspection today is a status check on a producing well. There are six wells on this pad; 3412124408, 3412124409, 3412124407, 3412124471, 3412124472, and 3412124428. During my inspection the well was equipped with a production tree style wellhead. The production valves are open. The production equipment consists of six gas processing units, eighteen 400 barrel tanks within containment, and two flare stacks. The production records are current, identification is located on the wellhead, and there are no violations present. |
0738320155 | 2016-03-21 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of ten 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds six production units. The production equipment is shared with five other wells on the pad. |
1036891940 | 2014-12-09 | Casing String Witnessed | No Violations | My inspection today finds the drilling rig is running 5.5 casing at a depth of 7220. Wyoming casing is providing the casing tong services. |
1115152785 | 2018-06-12 | Preliminary Restoration | No Violations | The purpose of my inspection was a status check on a preliminary restoration. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 860 pounds per square inch, 867 pounds per square inch on the production casing, 420 pounds per square inch on the 9.625 inch diameter intermediate casing, and 380 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of eighteen 400 barrel tanks, six gas production units, and two combustors. The identification was located at the wellhead. The area effected by the construction of the pad had been restored with no erosion present and vegetation coverage. The location has met the requirements for preliminary restoration written under 1509.072 (A). |
1280930945 | 2014-12-05 | Drill / Deepen / Reopen | No Violations | My inspection today finds the drilling rig, Patterson 332, is drilling 8.75 hole at a depth of 14,556. The anticipated total depth of the well is 17,600. |
1348531951 | 2014-03-05 | Drill / Deepen / Reopen | No Violations | My inspection finds the rig, Falcon 20, is rigging up. All producing wells on the pad are caged and shut in during the rig up process. |
136834401 | 2019-11-27 0:00 | PW | No Violations | 0.50 |
1394376823 | 2014-03-09 | Casing String Witnessed | No Violations | My inspection finds Falcon Drilling ran 401 of j-55 casing. Allied cementing circulated 848 sks of class A cement with 2% CaCl and .25 pps of Floseal per sk. I witnessed Allied weigh the cement twice with a pressurized cement scale. The first test weighed 15.7 ppg and the second weighed 15.6. There were 39 bbl of cement to surface. |
1424303163 | 2014-11-03 | Drill / Deepen / Reopen | No Violations | On November 2, 2014, 4:49 PM, I received a telephone call from Sam Myers of Antero Resources notifying me of a release of approximately 11 barrels of water based drilling fluid on containment. Mr. Myers also indicated that a small amount of the material was released over the site berm in the form of atomized mist. My inspection today of the site finds the spill on containment has been cleaned. I tested a small puddle, off site near the area of the release, with a low range Quantab and found the water to contain 193 parts per million total dissolved chlorides. |
201810431 | 2017-11-7 0:00: | PW | No Violations | 0.50 |
2115233097 | 2014-02-21 | Casing String Witnessed | No Violations | My inspection finds Express Energy Services drilled 100 of 30 hole. They then ran 100 of 26 casing. Express also cemented the casing in place with 330 sks of class A cement. I witnessed the cement at surface. |
354725626 | 2014-3-10 0:00: | DD | No Violations | 1.00 |
614544866 | 2018-11-1 0:00: | PW | No Violations | 0.50 |
648040932 | 2017-1-11 0:00: | PW | No Violations | 0.50 |
For data sources see[10]