Well Details

Well ID: 34-121-24493
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Marion Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000901
Farm/Lease Name: KAHRIG UNIT
License Status: Producing
License Date: 2014-05-14
Spud Date: 2014-06-06
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-07-16
Well Total Depth: 18606.00 ft
Configuration: Horizontal
Latitude: 39.810000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-05-14 Proposed Formations:POINT PLEASANT, Issued Date:5/14/2014, Expired Date:5/13/2016 12:00:00 PM, Drilling unit acres:492.086, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2014-07-16
Correction to Well 2015-01-30 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE INCREASED.
Completion Report Received 2015-10-23
Construction Permit Expires 2016-05-13
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2015-10-23 9378 0
9378 0
9378 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/20/2015 05/01/2015 8212 13,928,500.0 614914

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 8.86246 11,370,400.0
AI-301 U.S. Well Services Acid Corrosion Inhibitors Methenamine 100-97-0 20 0.00019 239.592
Coco amine 61791-14-8 5 0.00003000 41.4331
Hydrogen Chloride 7647-01-0 10 0.00008000 104.484
Diethylene Glycol 111-46-6 30 0.00024 302.372
Polyethylene polyamine 68603-67-8 10 0.00007000 90.7025
WFRA-405 U.S. Well Services Friction Reducer Petroleum Distillates 64742-47-8 20 0.01075 13791.3
Water 7732-18-5 40 0.02671 34264.1
Ethoxylated alcohol blend Proprietary 5 0.00334 4283.01
Anionic Polyacrylamide Proprietary 40 0.02671 34264.1
Sodium Chloride 7647-14-5 20 0.01335 17132
LGC-15 U.S. Well Services Gelling Agents Suspending agent (solid) 14808-60-7 3 0.00718 9217.22
Guar Gum 9000-30-0 50 0.04697 60266.4
Surfactant 68439-51-0 3 0.00282 3615.99
Petroleum Distillates 64742-47-8 60 0.04449 57075.8
Water Antero Resources Base Fluid Water 7732-18-5 100 90.5414 116,163,000.0
SI-1100 U.S. Well Services Scale Inhibitor 2-Phosphonobutane 1,2,4 tricarboxylic salt 37971-36-1 10 0.00165 2112.99
bis (hexamethylene) tramine penta

(methylene phosphonic acid) - phosphate acid

40623-75-4 10 0.00147 1883.67
Potassium salt of diethylene triamine

penta (methylene phosphonic acid)

15827-60-8 10 0.00172 2211.27
Di Water 7732-18-5 80 0.01021 13103.8
Copolymer of Maleic and Acrylic acid 26677-99-6 10 0.00151 1932.81
Acrylic polymer 52255-49-9 5 0.00064 818.988
hexamethylenediamine tetra (methylene phosphonic acid) 38820-59-6 10 0.0016 2047.47
Ethylene Glycol 107-21-1 40 0.00577 7403.65
AP One U.S. Well Services Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00197 2525
HCL Acid (12.6%-18.0%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 18 0.07329 94035.2
Water 7732-18-5 87.5 0.30684 393671
K-BAC 1020 U.S. Well Services Anti-Bacterial Agent Deionized Water 7732-18-5 28 0.00239 3061.45
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00418 5359.72

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-04-23 H2O 0 6514 Bbl 235500 US Well Services Inc

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION 1149387 9966 184
2016 ANTERO RESOURCES CORPORATION 1822958 3764 366
2017 ANTERO RESOURCES CORPORATION 843071 344 364
2018 ANTERO RESOURCES CORPORATION 538816 267 365
2019 ANTERO RESOURCES CORPORATION 104777 80 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION Brine 23803 184
2016 ANTERO RESOURCES CORPORATION Brine 14377 366
2017 ANTERO RESOURCES CORPORATION Brine 5848 364
2018 ANTERO RESOURCES CORPORATION Brine 3879 365
2019 ANTERO RESOURCES CORPORATION Brine 664 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1064333892 2018-2-2 0:00:0 PW No Violations 0.50
-1113977220 2019-8-13 0:00: PW No Violations 0.50
-1356113579 2017-11-20 0:00 PW No Violations 0.50
-1470229432 2014-6-17 0:00: DD No Violations
-2130937444 2015-11-16 0:00 PW No Violations 4.00
-216051084 2015-12-18 0:00 PW No Violations 2.00
-277619499 2017-1-18 0:00: PW No Violations 0.50
-283994270 2014-6-7 0:00:0 CS No Violations
-593262483 2015-11-17 0:00 PW No Violations 1.00
-857259462 2016-6-17 0:00: PW No Violations 0.50
0216051084 2015-12-18 Production Wells No Violations My inspection today finds the well has been returned to production. All of the equipment that was damaged in the fire has been removed from location. The drainage sumps have been cleaned and tested. The previous compliance notice has been resolved.
0277619499 2017-01-18 Production Wells No Violations The purpose of my inspection is a status check on a producing well. The pad name is Warner and there are a total of 7 wells on this pad. During my inspection the well was equipped with a production tree style wellhead. The production equipment for this well consists of ten 400 barrel tanks within containment, and seven gas processing units. The vapor recovery system consists of two compressors and three Cimarron combustors. The production records are current, the identification is located at the wellhead, and there are no violations present.
0283994270 2014-06-07 Casing String Witnessed No Violations My inspection finds the 30 conductor hole was drilled to a depth of 100. One hundred feet of 26 casing was welded together and ran to bottom. Express Well Services cemented the casing in place with 230 sks of class A cement.
0369539035 2015-04-23 Completion Testing No Violations My inspection today finds U.S. Well Service is providing hydraulic stimulation services. Sixty perforations were placed between 16,263 and 16,410. All volumes and pressures were recorded in the stimulation report.
0593262483 2015-11-17 Production Wells Violations Noted I am onsite to meet with Antero personnel to determine the source of the fire and the extent of the environmental impact. Mike Stellfox is onsite for the Fire Marshalls office. After examining the area I determined an area approximately 120 by 25 has areas of visible pooling of glycol on the surface of the ground. According to the company the entire pad was cement solidified and there are no under drains around the location. A 2 XXL heavy wall pipe nipple at the base of the high pressure shut off valve (motor valve) was found with a large wash out in the side of it. Antero personnel believe the pipe failure may be due to sand in the system. The company has submitted a plan to remove impacted soils and recover all free product.
0607918819 2014-06-10 Drill / Deepen / Reopen No Violations I am accompanied by Brandon Trigg. Our inspection today finds the drilling rig, Patterson 343, is drilling 17.5 hole at a depth of 940. The anticipated total depth for this string is 1860.
0857259462 2016-06-17 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery consists of twelve 400 barrel tanks set inside of a plastic lined steel containment system. Additionally, there are seven production units (GPUs) also set inside of a plastic lined steel containment system. Three Cimarron combustors and two compressors make up the vapor recovery system. A Meyers Well Service truck is on location hauling brine at the time of inspection.
1064333892 2018-02-02 Production Wells No Violations Status check following a nearby pipeline mechanical issue that is not owned by Antero. The purpose of my inspection today was a status check on a production well. The pad was named Warner and it consisted of 7 wells. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. The production equipment consisted of ten 400 barrel tanks, 7 gas production units, one vent scrubber, and 2 combustors. The natural gas pipeline tie in was located on the Northwest side of the pad with no issues present. The identification was located on the wellhead and production records were current.
1149208119 2015-12-07 Production Wells No Violations My inspection today finds the well is back in production. The production units has been replaced and the wellheads pressure tested. The drainage sumps are still closed. I requested the disposal manifests and the wellhead pressure test. The site is staffed by a Warrior employee 24 hours a day.
1304546357 2017-08-10 Production Wells No Violations The purpose of my inspection today was a status check on a production well. The pad was named Warner and it consisted of 7 wells. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. The production casing had a gauge present reading 404 pounds per square inch and the production tubing had a gauge present reading 208 pounds per square inch. The production equipment consisted of tin 400 barrel tanks, 7 gas production units, and 2 combustors. The natural gas pipeline tie in was located on the Northwest side of the pad. The identification was located on the wellhead.
1356113579 2017-11-20 Production Wells No Violations The purpose of my inspection today was a status check on a production well. The pad was named Warner and it consisted of 7 wells. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. The production equipment consisted of ten 400 barrel tanks, 7 gas production units, one vent scrubber, and 2 combustors. The natural gas pipeline tie in was located on the Northwest side of the pad. The identification was located on the wellhead and production records were current.
1402302417 2014-06-09 Casing String Witnessed No Violations My inspection today finds Patterson Drilling drilled 380 of 24 hole. The rig ran 376 of 18.625 casing. Allied cemented the casing in place with 726 sks of class A cement. I witnessed 60 barrels of cement return to surface.
1447889973 2015-11-18 Production Wells No Violations I am accompanied by Scott King and Trisha Cartmell. My inspection finds that all standing glycol has been removed. 3200 gallons of glycol were recovered from the production units. All wells on the pad remain shut in at this time. Once insurance adjusters are able to inspect the site the damaged units will be removed and repairs will resume.
1448064759 2015-11-20 Production Wells No Violations My inspection today finds the well is shut in. Well Service Group is on site and rebuilding the containment around the four productions units that were not affected by the fire. No glycol is visible on the ground. All drainage sumps are still closed and locked.
1470229432 2014-06-17 Drill / Deepen / Reopen No Violations Patterson rig 343 is drilling 12.25 hole at a depth of 6250. The location is well vegetated and erosion controls are in place.
1999691521 2015-07-30 Preliminary Restoration No Violations My inspection today finds the well site meets the preliminary restoration requirements of 1509.072(A). Well Service Group is onsite removing matting boards. The well has not been connected to production pipelines. The lease road has recently been treated with a dust suppression product.
2130937444 2015-11-16 Production Wells No Violations At 9:40 pm I received a call from Scott King stating that multiple fires were reported at the well site. The Caldwell VFD, Summerfield VFD and Quaker City VFD were on site upon my arrival at 10:15 pm. The fire was out at the time of my arrival. I found the production units for the Kahrig 3H, Daily 1H and the Daily 2H were damaged by fire. I walked the perimeter of location and checked the drainage sumps. The drainage sumps were closed and access to the valves was locked. Antero shut the sump last drain sump at 9:54 pm. Antero staffed the location with two security personnel to secure the well pad. At 11:03 I notified Sam Myers and Arron Goddard that Antero is in violation of 1509.22(A).
369539035 2015-4-23 0:00: CT No Violations 4.00
607918819 2014-6-10 0:00: DD No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0593262483 US-OH-126677 2016-02-19 Well operation causing pollution and contamination

For data sources see[10]