Well Details

Well ID: 34-121-24497
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Beaver Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000817
Farm/Lease Name: CARL UNIT
License Status: Producing
License Date: 2014-06-02
Spud Date: 2014-06-03
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-11-29
Well Total Depth: 16120.00 ft
Configuration: Horizontal
Latitude: 39.900000
Longitude: -81.320000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-06-02 Proposed Formations:POINT PLEASANT, Issued Date:6/2/2014, Expired Date:6/1/2016 12:00:00 PM, Drilling unit acres:454.155, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2014-11-29
Correction to Well 2015-01-30 UPDATE TO UNIT SIZE. CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2015-08-20
Construction Permit Expires 2016-06-01
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/28/2015 05/09/2015 7769 11,344,300.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFR-6W C&J Well Services Friction Reducer Anionic Water-Soluble Polymer Emulsion Proprietary 100 0.063938 0
LSG-100L C&J Well Services Gelling Agents Petroleum Distillates 64742-47-8 70 0.038454 0
Acid Inhibitor 2 (AI-2) C&J Well Services Acid Corrosion Inhibitors 2-Butoxyethanol 111-76-2 20 0.000141 0
Isopropyl Alcohol 67-63-0 20 0.000141 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00007000 0
Proprietary Proprietary 15 0.000105 0
Propargyl Alcohol 107-19-7 20 0.000141 0
AQUCAR DB 20 C&J Well Services Biocides Dibromoacetonitrile 3252-43-5 3 0.000414 0
Polyethylene glycol 25322-68-3 54.5 0.007519 0
Sodium bromide 7647-15-6 4 0.000552 0
2,2-Dibromo-3-nitrilo-propionamide (DBNPA) 10222-01-2 20 0.002759 0
Super TSC 2 LT C&J Well Services Paraffin & Scale Additives Bis(hexamethylene triaminepenta
(methylenephosphonic acid))
Proprietary 10 0.001672 0
Water ANTERO RESOURCES Water Water 7732-18-5 100 89.4463 0
Other Ingredients C&J Well Services Other Ingredients Water 7732-18-5 40 0.025575 0
Proprietary Proprietary 0.99 0.00000700 0
2-Propenamide as residual 79-06-1 0.1 0.00006400 0
guar gum 9000-30-0 50 0.027467 0
Glycol Ethers 111-46-6 40 0.000281 0
Ethoxylated alcohols Proprietary 4 0.002558 0
Water 7732-18-5 100 0.000212 0
Copolymer Proprietary 100 0.063938 0
Sodium Hydroxide 1310-73-2 1 0.000167 0
Monobromo-3-nitrilopropionamide 1113-55-9 1 0.000138 0
Proprietary Proprietary 0.02 0 0
Proprietary Proprietary 1 0.00000400 0
Crystalline Silica (in the form of quartz) 14808-60-7 2 0.001099 0
Isoparaffinic Solvent 64742-47-8 26 0.016624 0
Organophylic Clay 68953-58-2 0 0 0
Sugar 57-50-1 100 0.000423 0
Ethylene Glycol 107-21-1 4 0.002558 0
Water 7732-18-5 48 0.000337 0
Water 7732-18-5 32 0.004415 0
Surfactant 68439-51-0 2 0.001099 0
Proprietary Proprietary 100 0.000423 0
Cured Acrylic Resin Proprietary 22 0.000216 0
2,2-Dibromomalonamide 73003-80-2 1 0.000138 0
Water 7732-18-5 90 0.015052 0
Surfactant Blend Proprietary 3 0.001918 0
EB-4L C&J Well Services Gel Breakers Ethylene Glycol 107-21-1 40 0.000169 0
OB-2 LT C&J Well Services Gel Breakers Talc 14807-96-6 1 0.00001000 0
Ammonium Persulfate 7727-54-0 85 0.000836 0
Super GREEN SOLV-M C&J Well Services Paraffin & Scale Additives Aliphatic Hydrocarbons Proprietary 95 0.000462 0
Dodecane Proprietary 14 0.00006800 0
Tridecane Proprietary 9 0.00004400 0
tetradecane Proprietary 11 0.00005300 0
Undecane Proprietary 8 0.00003900 0
HCl Acid (12.5-18.0%), 22 Baume C&J Well Services Bulk Acid Hydrochloric Acid 7647-01-0 18 0.067059 0
Water 7732-18-5 87.5 0.325982 0
Sand C&J Well Services Sand - Bulk - West Virginia Titanium Oxide 13463-67-7 0.1 0.004105 0
Crystalline Silica, quartz 14808-60-7 99.9 4.52415 0
Aluminum Oxide 1344-28-1 1.1 0.045156 0
Titanium Oxide 13463-67-7 0.1 0.004529 0
Crystalline Silica, quartz 14808-60-7 99.9 1.39393 0
Iron Oxide 1309-37-1 0.1 0.001395 0
Titanium Oxide 13463-67-7 0.1 0.001395 0
Crystalline Silica, quartz 14808-60-7 99.9 4.10103 0
Aluminum Oxide 1344-28-1 1.1 0.049815 0
Iron Oxide 1309-37-1 0.1 0.004105 0
Aluminum Oxide 1344-28-1 1.1 0.015349 0
Iron Oxide 1309-37-1 0.1 0.004529 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION 1017143 45160 184
2016 ANTERO RESOURCES CORPORATION 899667 9047 359
2017 ANTERO RESOURCES CORPORATION 439333 3190 365
2018 ANTERO RESOURCES CORPORATION 238060 1322 342
2019 ANTERO RESOURCES CORPORATION 66584 389 90

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION Brine 13504 184
2016 ANTERO RESOURCES CORPORATION Brine 6858 359
2017 ANTERO RESOURCES CORPORATION Brine 3288 365
2018 ANTERO RESOURCES CORPORATION Brine 1916 342
2019 ANTERO RESOURCES CORPORATION Brine 532 90

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1419692932 2014-11-17 0:00 DD No Violations 1.00
-1813566774 2019-12-5 0:00: PW No Violations 0.50
-1932395252 2017-1-25 0:00: PW No Violations 0.10
-65430217 2014-6-13 0:00: CS No Violations 3.00
-699812004 2015-8-3 0:00:0 PL No Violations 0.50
-736721283 2016-1-13 0:00: PW No Violations 0.30
-980603213 2017-8-7 0:00:0 PW No Violations 0.20
0065430217 2014-06-13 Casing String Witnessed No Violations I am onsite to witness the surface casing cementing operations. Falcon rig 27 drilled 380 of 24 hole and ran 367 of 18.625 inch 87.5 pound casing. Allied Oil and Gas Services circulated 757 sacks of class A cement into place. The cement mix water tested at 101 ppm chlorides on a low range Quantab.
0699812004 2015-08-03 Preliminary Restoration No Violations My inspection today finds the well site meets the preliminary restoration requirements of 1509.072(A). The well is produced into a tank battery comprised of fourteen 400 barrel tanks set inside of a plastic lined steel containment.
0736721283 2016-01-13 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of fourteen 400 barrel tanks set inside of a plastic lined, liquid tight steel containment system. There are four incinerators set at the location. Seven other wells are located on the pad and share the production equipment. The ground is covered by three inches of snow at the time of inspection.
0980603213 2017-08-07 Production Wells No Violations The purpose of my inspection today was a status check on a production well. The pad was named Ervin and it consisted of 8 wells. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. The production casing had a gauge present reading 243 pounds per square inch and the production tubing had a gauge present reading 168 pounds per square inch. The production equipment consisted of fourteen 400 barrel tanks, 8 gas production units, 4 compressors, and 2 combustors. The natural gas pipeline tie in was located on the south side of the pad. The identification was located on the well and the 400 barrel tank.
1095806256 2015-07-10 Production Wells No Violations Status check inspection as a follow up to a on site accident that occurred on 07-08-2015. Upon inspection on this day I met with Anteros HSE representative Chris Warnock and Myers Well Service Regional Safety officer John Moore who indicated the employee of Myers Well Service was injured when a 3 line used in the production fluid transfer process was attempted to be disconnected from the water truck while under pressure causing the line to release from its connection and struck the employee in the face causing lacerations and fractures to the face. The line was free from fluid and no well bore related product was released. The company(Antero) has implemented a safety stand down until the incident can be investigated and corrections can be made to further avoid any future incidents. Addressing the well location a total of 8 wells were found on site and in production with a total of 14 production tanks present with a total capacity of 400 barrels each. All tanks were found inside of a poly lined metal construction containment dike area. Also on site there is a total of 8 gas processing units one supporting each existing well on the location. With proper well identification posted at the well head. Myers Well Service Ohio UIC # 25-427 water trucks were on location along with Ohio Oil Gathering hauling production fluid from the site.
1402937165 2014-06-16 Casing String Witnessed No Violations My inspection today finds Falcon rig 27 drilled a 17.5 hole to a depth of 1905. The rig crew ran 1870 of 13.625 casing. Allied cemented the casing in place with 1427 sacks of class A cement. I witnessed 22 barrels of cement to surface.
1419692932 2014-11-17 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig, Patterson 340, is building the bottom hole assembly to begin drilling the 8.75 curve and lateral.
1932395252 2017-01-25 Production Wells No Violations The purpose of my inspection is a status check on a producing well. The pad name is Ervin Pad and there are a total of 8 wells on this pad. During my inspection the well was equipped with a production tree style wellhead. The production equipment for this well consists of 14 400 barrel tanks within containment, and eight gas processing units. The vapor recovery system consists of two compressors and four Cimarron combustors. The production records are current, the identification is located at the wellhead, and there are no violations present.
2055553061 2015-06-03 Completion Testing No Violations My inspection today finds the service contractor, Fortis, has drilled out 32 completion plugs and are currently drilling plug number 33. Fire extinguishers are located around location as required.

For data sources see[8]