X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-24603

Well Details

Well ID: 34-121-24603
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Beaver Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-001330
Farm/Lease Name: BRION UNIT
License Status: Producing
License Date: 2016-04-08
Spud Date: 2016-03-10
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2016-05-10
Well Total Depth: 15886.00 ft
Configuration: Horizontal
Latitude: 39.880000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-02-26 Proposed Formations:POINT PLEASANT, Issued Date:2/26/2016, Expired Date:2/25/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2016-04-08 Proposed Formations:POINT PLEASANT, Issued Date:4/8/2016, Expired Date:4/8/2018 12:00:00 PM, Drilling unit acres:260.889, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2016-05-10
Correction to Well 2016-12-30 CHANGE TARGET/TAKEPOINT PER AS-DRILLED PLAT RCVD 11-28-16-ALE.
Completion Report Received 2017-01-13
Record Last Modified 2017-10-23
Construction Permit Expires 2018-04-08

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-01-13 8532 15794 0
8532 15794 0
8532 15794 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/27/2016 10/12/2016 8385 10,686,500.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFRA-405 U.S. Well Services, LLC Friction Reducer 2-Propenoic acid, polymer with 2 propenamide 9003-06-9 30 0.02985 30006.5
Hydrated light distillate (petroleum) 64742-47-8 30 0.02403 24155.2
K-BAC 1020 U.S. Well Services, LLC Anti-Bacterial Agent Deionized Water 7732-18-5 28 0.00247 2479.98
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00432 4341.74
AP One U.S. Well Services, LLC Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00111 1119
LGC-15 U.S. Well Services, LLC Gelling Agents Guar Gum 9000-30-0 50 0.02485 24984.5
Surfactant 68439-51-0 3 0.00149 1499.07
Suspending agent (solid) 14808-60-7 3 0.0038 3821.15
Petroleum Distillates 64742-47-8 60 0.02354 23661.8
SI-1100s U.S. Well Services, LLC Scale Inhibitor Copolymer of Maleic and Acrylic acid 52255-49-9 10 0.0015 1504.72
Hexamethylene tramine penta (methylene phosphonic acid) 34690-00-1 3 0.00049 497.323
Phosphino carboxylic acid polymer 71050-62-9 3 0.00049 497.323
Potassium salt of diethylene triamine

penta (methylene phosphonic acid)

15827-60-8 3 0.00051 516.45
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 11.0118 11,070,800.0
AI-302 U.S. Well Services, LLC Acid Corrosion Inhibitors Water 7732-18-5 95 0.00039 388.227
2-Propyn-1-olcompound with methyloxirane 38172-91-7 15 0.00006000 61.299
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 17.5 0.04126 41479
Water 7732-18-5 87.4 0.17746 178406
Water Antero Resources Carrier/Base Fluid Water 7732-18-5 100 88.6506 89,125,500.0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2016-10-12 H2O 0 5563 Bbl 265320 US Well Services Inc STAGE 42/42

60 SHOTS

2016-09-27 H2O 0 6391 Bbl 266180 US Well Services Inc STAGE 1/42

60 SHOTS STAGES 2-41 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 ANTERO RESOURCES CORPORATION 93295 484 31
2017 ANTERO RESOURCES CORPORATION 2418142 3229 365
2018 ANTERO RESOURCES CORPORATION 701880 249 365
2019 ANTERO RESOURCES CORPORATION 122110 125 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 ANTERO RESOURCES CORPORATION Brine 2263 31
2017 ANTERO RESOURCES CORPORATION Brine 35263 365
2018 ANTERO RESOURCES CORPORATION Brine 6656 365
2019 ANTERO RESOURCES CORPORATION Brine 1565 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1483938774 2016-3-10 0:00: CS No Violations 5.00
-1628505053 2017-10-24 0:00 PW No Violations 0.20
-58624532 2016-10-11 0:00 CT No Violations 1.10
-776486448 2019-8-20 0:00: PW No Violations 0.50
-798997328 2017-3-16 0:00: PW No Violations 0.10
-852945979 2016-4-13 0:00: CS No Violations 5.50
0058624532 2016-10-11 Completion Testing No Violations
0798997328 2017-03-16 Production Wells No Violations The pad is named Quintel and it consists of 10 wells. The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Annular pressure monitoring was present. The production equipment consisted of 10 sand traps, 10 gas production units, fourteen 400 barrel tanks, three compressors, and four combustors. Identification was present and production records were current.
0852945979 2016-04-13 Casing String Witnessed No Violations I am onsite to witness the surface casing installation and cementing operations. Patterson Drilling rig 342 drilled a 17.5 borehole to a depth of 1080. The drilling rig then installed 1074 of J-55 13.375 casing with power tong services provided by Wyoming Casing. Halliburton cemented the casing in place with 1010 sacks of HalCem with 39 barrels of cement circulating to surface. The casing integrity test was passed.
1030141679 2017-05-16 Production Wells No Violations The pad is named Quintel and it consists of 10 wells. The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Annular pressure monitoring was present. The production equipment consisted of 10 sand traps, 10 gas production units, fourteen 400 barrel tanks, three compressors, and four combustors. Identification was present and production records were current. Myers Well Services had four trucks on location hauling produced fluids from the tank battery. Dust suppression was recently applied on the lease road by Ramco.
1483938774 2016-03-10 Casing String Witnessed No Violations My inspection today finds Express Energy drilled 102 of 32 borehole and ran 100 of 26 weld casing. Express Energy cemented the casing in place with 330 sacks of class A cement. I witnessed good cement circulate to surface.
1583034543 2018-09-18 Preliminary Restoration No Violations The Quintel Pad consists of 10 wells and 1 conductor. The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead. Production valves were in the open position. Annular pressure monitoring was present and evaluated. The production equipment consisted of ten gas production units, fourteen 400 barrel tanks, three compressors, and two combustors. Identification was present and production records were current. Location meets 1509.72 (A) requirements.
1628505053 2017-10-24 Production Wells No Violations The purpose of my inspection was a status check on a production well. The pad is named Quintel and it consists of 10 wells. The well was equipped with a production tree style wellhead. Production valves were in the open position. Production and annular pressure monitoring was present. Gauges were covered with plastic today due to the wellheads being recently painted. The production equipment consisted of ten gas production units, fourteen 400 barrel tanks, three compressors, and four combustors. Identification was present and production records were current. A Myers Well Services truck was on location hauling produced fluids from the tank battery and Antero well tender was on location. The pipeline tie in was located on the West side of the pad. The identification was located at the wellhead and the production records were current.
1844986218 2016-06-17 Plug / Plug Back No Violations My inspection today finds the site meets the preliminary restoration requirements of 1509.072(A).

For data sources see[10]

References