34-127-26530

Well Details

Well ID: 34-127-26530
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Harrison Township
Operator Name: SWINGLE DRILLING INC
Well Pad ID:
Farm/Lease Name: TAYLOR-CEMETERY UNIT
License Status: Producing
License Date: 1984-12-24
Spud Date: 1985-01-28
Spud Drilling Contractor: AZTEC DRLG
Final Drill Date: 1985-02-03
Well Total Depth: 3820.00 ft
Configuration: Vertical
Latitude: 39.760000
Longitude: -82.100000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-12-24 Issued Date 12/24/84 Expired Date 6/22/85 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03820 Proposed Drill Depth 03820
Original Spud 1985-01-28
Completed 1985-02-03
Reached Total Depth 1985-02-03
CO 1985-03-25 50 SWINGLE DRILLING INC GeoDate 12/24/84
Completion Report Received 1985-06-05
Construction Permit Expires 1985-06-22
Last Compliance Report 2018-04-19
Record Last Modified 2018-04-19

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3578 3634 0
3578 3634 0
3578 3634 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 33000 Gal 29000 2ND STG.
H2O 0 64000 Gal 29000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 SWINGLE DRILLING INC 3616.00 739.00 0
1986 SWINGLE DRILLING INC 2581.00 477.00 365
1993 SWINGLE DRILLING INC 4133.00 0.00 365
1995 SWINGLE DRILLING INC 2855.00 0.00 365
2000 SWINGLE DRILLING INC 774.00 74.00 365
2001 SWINGLE DRILLING INC 199.00 0.00 365
2002 SWINGLE DRILLING INC 81.00 63.00 365
2003 SWINGLE DRILLING INC 0.00 0.00 0
2004 SWINGLE DRILLING INC 0.00 0.00 0
2005 SWINGLE DRILLING INC 0.00 0.00 365
2006 SWINGLE DRILLING INC 28.00 0.00 180
2007 SWINGLE DRILLING INC 275.00 75.00 365
2008 SWINGLE DRILLING INC 0.00 63.00 365
2009 SWINGLE DRILLING INC 0.00 0.00 365
2010 SWINGLE DRILLING INC 0.00 0.00 0
2011 SWINGLE DRILLING INC 0.00 0.00 365
2012 SWINGLE DRILLING INC 0.00 0.00 0
2013 SWINGLE DRILLING INC 0.00 0.00 0
2014 SWINGLE DRILLING INC 0.00 0.00 365
2015 SWINGLE DRILLING INC 286.00 0.00 365
2016 SWINGLE DRILLING INC 10.00 0.00 365
2017 SWINGLE DRILLING INC 0.00 23.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 SWINGLE DRILLING INC Brine 60 0
1986 SWINGLE DRILLING INC Brine 48 365
1993 SWINGLE DRILLING INC Brine 0 365
1995 SWINGLE DRILLING INC Brine 0 365
2000 SWINGLE DRILLING INC Brine 0 365
2001 SWINGLE DRILLING INC Brine 0 365
2002 SWINGLE DRILLING INC Brine 0 365
2003 SWINGLE DRILLING INC Brine 0 0
2004 SWINGLE DRILLING INC Brine 0 0
2005 SWINGLE DRILLING INC Brine 0 365
2006 SWINGLE DRILLING INC Brine 0 180
2007 SWINGLE DRILLING INC Brine 0 365
2008 SWINGLE DRILLING INC Brine 0 365
2009 SWINGLE DRILLING INC Brine 0 365
2010 SWINGLE DRILLING INC Brine 0
2011 SWINGLE DRILLING INC Brine 0 365
2012 SWINGLE DRILLING INC Brine 0 0
2013 SWINGLE DRILLING INC Brine 0 0
2014 SWINGLE DRILLING INC Brine 0 365
2015 SWINGLE DRILLING INC Brine 0 365
2016 SWINGLE DRILLING INC Brine 0 365
2017 SWINGLE DRILLING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-104758264 2013-2-28 0:00: PW No Violations 0.50
-116162053 2019-3-29 0:00: PW No Violations 0.50
-431258800 2019-4-15 0:00: PW No Violations 0.50
-513035673 2016-3-9 0:00:0 AD No Violations
0000PL6667 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0104758264 2013-02-28 Production Wells No Violations This well is capable of production. It has a pumping unit on it with rods and tubing. The motor was missing so I talked with a Mark Swingle and he told me that someone stole the motor. They are getting gas off of the well to heat there office. They plan on either plugging the well or plugging it back when they lose there gas.
0113217304 2018-01-26 Production Wells No Violations I returned to this well today to do a follow-up inspection on it. At this time the well is no longer in violation. The well is being used for domestic gas. There are no violations at this time.
0116162053 2019-03-29 Production Wells Violations Noted I was on location to respond to a gas leak that was called in on this well. The leak is coming from the casing wellhead and is under the ground. I called Mark Swingle to see when he would be out but did not get an answer. Mark ended up calling me back over the weekend and he will get it fixed on Sunday. I will return to the well on Monday to check it.
0431258800 2019-04-15 Production Wells No Violations I was back on location today to follow-up on the gas leaking from the casing wellhead. Mark Swingle has connected the surface casing to the production line and is now selling the gas. The well is no longer leaking and is in compliance.
0454199171 2013-02-28 Annular Disposal No Violations The annular disposal is not hooked up on this well.
0513035673 2016-03-09 Annular Disposal Violations Noted Accompanied by Scott King during inspection. The inspection revealed well is idle, no production reported to the Division since 2008. The well owner/operator shall submit a written plugging schedule to (Justin Smith) at (5880 Memory Road Zanesville, Ohio 43701) within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. Identification faded at well and tank battery, Identification needs replace at well and tank battery in a legible manner.
0715595296 2017-12-05 Temporary Abandoned Annular Disposal No Violations I am on location today to check the annular disposal for Columbus. The annular disposal is not hooked up on this well at this time.
113217304 2018-1-26 0:00: PW No Violations 0.50
1210633977 2008-06-10 Annular Disposal No Violations No violations.
1239480340 2016-06-14 Production Wells No Violations I returned to this well to do a follow-up inspection on it. The well is still currently in violation.
1278802970 2007-01-09 Annular Disposal No Violations Checked AD hook up for Columbus, AD not in use.
1280i14659 2002-05-15 Annular Disposal No Violations A.D. NOT BEING USED.
1280i14659171 2002-5-15 0:00: AD No Violations
1400936153 2019-04-01 Production Wells No Violations I was back on location today to follow-up on the leak coming from the valve on the casing. Mark Swingle has been out and put a bull plug in the valve to stop the leaking. When I arrived on location the hole has filled back up with water and there were bubbles coming to the surface. I could not smell any gas but I did contact Mark to let him know it was still bubbling. He is going to come back out and put a gauge on the well to see how much pressure there is on it. If it has a lot of pressure he will tie it into his other line to sell the gas.
454199171 2013-2-28 0:00: AD No Violations 0.50
715595296 2017-12-5 0:00: TD No Violations 0.50
PL6667 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0116162053 US-OH-104290 2019-04-22 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
0513035673 US-OH-125601 2018-04-23 9-9-05(A)10 Failure to legibly identify well
0513035673 US-OH-125602 2018-04-23 NONE E Well shall be plugged