X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-145-20303

Well Details

Well ID: 34-145-20303
Loading map...
Country: United States
State: Ohio
County: Scioto
Municipality: Madison Township
Operator Name: CONLEY JAMES D
Well Pad ID:
Farm/Lease Name: ISON LUTHER & MATILDA
License Status: Domestic Well
License Date: 1983-01-12
Spud Date: 1983-03-28
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1983-03-30
Well Total Depth: 1114.00 ft
Configuration: Vertical
Latitude: 38.930000
Longitude: -82.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 1862 CONLEY JAMES D
CO 1982-05-18 85 MAJ GeoDate 5/18/82
Oil and Gas 1982-05-18 Issued Date 5/18/82 Expired Date 11/15/82 Acres 0010000 Tool Type RTA Proposed Formation OHIO SHALE Proposed Depth 00000 Proposed Drill Depth 00000
CO 1983-01-12 1862 CONLEY JAMES D GeoDate 1/12/83
Oil and Gas 1983-01-12 Issued Date 1/12/83 Expired Date 7/11/83 Acres 0010000 Tool Type RTA Proposed Formation OHIO SHALE Proposed Depth 01114 Proposed Drill Depth 01114
Original Spud 1983-03-28 R.I. 1-21-84
Completed 1983-03-30 R.I. 1-21-84
Reached Total Depth 1983-03-30 R.I. 1-21-84
Construction Permit Expires 1983-07-11 R.I. 1-21-84
Completion Report Received 1983-10-19 R.I. 1-21-84
Record Last Modified 2017-02-15 R.I. 1-21-84

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 624 0
624 0
624 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 NONE

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1014381101 2013-2-11 0:00: PW No Violations 0.50
-2042527890 2016-2-29 0:00: PW No Violations 1.50
-2131626824 2013-2-11 0:00: PW No Violations 0.50
-556000052 2019-2-5 0:00:0 PW No Violations 0.20
-900660419 2013-2-11 0:00: PW No Violations 1.50
0000PL5696 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0243773624 2018-08-30 Production Wells No Violations My inspection revealed the well had a pvc pipe covering the well. I removed the pipe to inspect the well and found what appeared to be surface casing at the surface. The was what appeared to be 5.5 inch diameter casing with a swage to 2 inch diameter. The casing and swage were to rusty to measure or even see if there was a valve on the swage. Water was seen leaking out of the surface casing. There was a scald area approximately 5 feet by 14 feet. The scald area was covered in deer tracks. The original violations for pollution and contamination and lack of a legible identification have not been resolved. At 11:24 AM I called the phone number listed for contact and found that number has been disconnected.
0556000052 2019-02-05 Production Wells No Violations My inspection revealed the well did not have legible identification. I will attempt to contact the owner of the well regarding bringing this well into compliance.
0900660419 2013-02-11 Production Wells No Violations Accompanied Morgan Button MRI 2 on inspection. No identification. Wellhead not visible at the surface. A tractor tire and rim has been placed over the well. Fluid was observed below the rim approximately 12 down.
1014381101 2013-02-11 Production Wells No Violations FOLLOW UP TO NOV # 1595893386 Well identification sign is missing at wellhead. According to 1501:9-9-05(A)10/1509:23 the well identification sign shall include owners name, county, township, well name and number, permit number for the well, and emergency contact number. There is no tank battery associated with this well. Refer to inspectors report # -2131626824 for further information on the compliance concerning the leak at this well.
1073431691 2015-09-23 Production Wells No Violations Follow up to notice 2131626824 issued to DM well by Morgan Button. Violations not resolved. I spoke with the landowner about correcting the issue and told her Id be back in two months to check.
1313545698 2006-04-20 Production Wells No Violations Can see the casing head at ground level but well head removed; post stuck in hole with tractor tire surrounding it.
1471099012 2014-04-23 Production Wells No Violations Compliance notice follow-up. The well is not in compliance, there is no legible identification.
1595893386 2013-02-11 Production Wells Violations Noted Well identification sign is missing at wellhead. According to 1501:9-9-05(A)10/1509:23 the well identification sign shall include owners name, county, township, well name and number, permit number for the well, and emergency contact number. There is no tank battery associated with this well. Refer to inspectors report # -2131626824 for further information on the compliance concerning the leak at this well.
1683213550 2015-12-07 Production Wells No Violations Follow up to notice 2131626824 issued to DM well by Morgan Button. Violations not resolved. I spoke with the landowner about correcting the issue, she mentioned her son would be repairing the well and I gave her my contact information to have him call me and discuss remediation of the violation.
1827570266 2013-02-11 Production Wells No Violations FOLLOW UP TO NOV # -2131626824 There is a 8-5/8 inch inside diameter casing ending at the surface with a approximately 2-inch production tubing rising about four feet above the ground surface. For production tubing protection a thick gauged PVC pipe was placed over the tubing rising another foot above the top of the tubing. Gas and brine was observed leaking out of the top of the tubing. Brine was flowing from under the PVC pipe and flowing from the wellhead. There is a brine scald area 12-feet long and 2-feet wide coming from the pipe. Low concentration Quantab (30-600ppm) measurement was above 600 ppm but confirmed chloride containing fluid was coming from the well head. According to 1501:9-9-05(A)1/1509:20 the well is insufficiently equipped to prevent the escape of gas and brine is contaminating the ground surface. Repairs must be implemented to mitigate this problem. Well must be sufficiently equipped to prevent pollution and contamination. All contaminated soil must be removed and disposed of properly. The scald area impacted by brine shall be seeded and mulched and steps shall be taken to encourage vegetative growth, There is no tank battery associated with this well.
2042527890 2016-02-29 Production Wells No Violations FOLLOW UP TO NOV # -213162682. There was a logging crew in the area loading and dragging logs. I could not get to well at this time.
2131626824 2013-02-11 Production Wells Violations Noted There is a 8-5/8 inch inside diameter casing ending at the surface with a approximately 2-inch production tubing rising about four feet above the ground surface. For production tubing protection a thick gauged PVC pipe was placed over the tubing rising another foot above the top of the tubing. Gas and brine was observed leaking out of the top of the tubing. Brine was flowing from under the PVC pipe and flowing from the wellhead. There is a brine scald area 12-feet long and 2-feet wide coming from the pipe. Low concentration Quantab (30-600ppm) measurement was above 600 ppm but confirmed chloride containing fluid was coming from the well head. According to 1501:9-9-05(A)1/1509:20 the well is insufficiently equipped to prevent the escape of gas and brine is contaminating the ground surface. Repairs must be implemented to mitigate this problem. Well must be sufficiently equipped to prevent pollution and contamination. All contaminated soil must be removed and disposed of properly. The scald area impacted by brine shall be seeded and mulched and steps shall be taken to encourage vegetative growth, There is no tank battery associated with this well.
243773624 2018-8-30 0:00: PW No Violations 0.70
PL5696 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1595893386 US-OH-115614 2013-02-22 Failure to legibly identify well
2131626824 US-OH-121843 2013-02-22 Well operation causing pollution and contamination
2131626824 US-OH-121844 2013-02-22 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[5]

References