Well Details

Well ID: 34-155-22669
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hartford Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: PEPE
License Status: Producing
License Date: 1984-10-18
Spud Date: 1985-01-11
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1985-01-17
Well Total Depth: 5012.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -80.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-10-18 Issued Date 10/18/84 Expired Date 4/16/85 Acres 0045000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05012 Proposed Drill Depth 05012
Original Spud 1985-01-11
Completed 1985-01-17
Reached Total Depth 1985-01-17
CO 1985-01-31 54 TITAN ENERGY CORP GeoDate 10/18/84
Completion Report Received 1985-02-12
Construction Permit Expires 1985-04-16
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4802 4880 0
4802 4880 0
2006-09-11 4820 4869 19
4820 4869 19
4802 4880 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 67500 Gal 70000
N2 0 168 Mscf 0
ACID 0 500 Gal 0 FRAC;H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 TITAN ENERGY CORP 2003.00 0.00 365
1990 TITAN ENERGY CORP 1082.00 58.00 365
1991 POWER GAS MARKETING & TRANS 1053.00 62.00 365
1992 TITAN ENERGY CORP 914.00 0.00 365
1993 TITAN ENERGY CORP 269.00 0.00 365
1994 TITAN ENERGY CORP 76.00 58.00 365
1997 TITAN ENERGY CORP 0.00 23.00 245
2000 BIG SKY ENERGY INC 668.00 77.00 365
2001 BIG SKY ENERGY INC 317.00 0.00 365
2002 BIG SKY ENERGY INC 1354.00 61.00 365
2003 BIG SKY ENERGY INC 1765.00 0.00 365
2004 BIG SKY ENERGY INC 1215.00 52.00 365
2005 BIG SKY ENERGY INC 1852.00 0.00 365
2006 BIG SKY ENERGY INC 2403.00 0.00 365
2007 BIG SKY ENERGY INC 2482.00 28.00 365
2008 BIG SKY ENERGY INC 3327.00 49.00 365
2009 BIG SKY ENERGY INC 1682.00 0.00 365
2010 BIG SKY ENERGY INC 1946.00 29.00 365
2011 BIG SKY ENERGY INC 2028.00 0.00 365
2012 BIG SKY ENERGY INC 843.00 0.00 366
2013 BIG SKY ENERGY INC 240.00 7.00 280
2014 BIG SKY ENERGY INC 97.00 0.00 365
2016 BIG SKY ENERGY INC 209.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 POWER GAS MARKETING & TRANS Brine 101 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 17 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 280
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1661180966 2016-4-11 0:00: PW No Violations
-1809094991 2013-3-20 0:00: PW No Violations 0.50
0000PL3656 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1363959664 2012-10-18 Production Wells No Violations My inspection found this well in production. The well was equipped with a 4 concoil unit. The tank battery contained one, rusty, 100 barrel production tank and one, rusty, 50 barrel brine tank. It was surrounded by a very weathered dike not capable of containment requirements. There was a pond within 25 to 30. There were weeds, small trees, and debris around the production and brine tank. There was a plug in the load line. The heat treated separator had the correct spacing from the tank battery. A stenciled identification sign was posted on the production tank with half of the required information. The lease road was in good, stable condition and shared with permit number 2-2668. According to our database, the last reported production was in 2010. I called Big Sky at 740-624-0434. I instructed Big Sky to remove the weeds and small trees from around the tank battery. Also, I told them to build the proper dike around the tank battery and separator.
1472828914 2016-09-02 Production Wells No Violations
1661180966 2016-04-11 Production Wells No Violations I was on location in reference to compliance notice 1809094991. My inspection found the well to be equipped with a concoil wellhead. The valves on the well are in the open position. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank. The heated separator is outside of the tank battery with the proper spacing. There is a domestic supply plumbed into the sales portion of the separator. The tank battery is over grown with brush. The identification sign is faded and needs to be updated. The brush needs to be removed from inside the tank battery and a dike needs built around the production and brine tank as requested per the previous compliance notice. The lease road is in stable condition and is being shared by permit 2-2668.
1807340725 2019-8-19 0:00: PW No Violations
1809094991 2013-03-20 Production Wells Violations Noted My inspection found the weeds and small trees still located around the tank battery. The dike I requested to be built around the tank battery and separator on 10/18/2012 was not built. I called Jamie Campbell at 440-858-7252. He said he did not remember that I requested a dike to be built. Jamie said that he would contact Bob Barr Jr. about the dike request. I informed Jamie that I was issuing a compliance notice. I took photos of the tank battery and separator to document their condition.
2088542046 2018-03-19 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1809094991. The well was equipped with a Concoyle plunger lift assembly and the annulus and flow line valves were closed. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open. The tank battery still needs the dike rebuilt around the production equipment. Signage was legible at the tank battery. The lease access was stable.
PL3656 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1809094991 US-OH-118075 2013-03-22 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]