X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23751

Well Details

Well ID: 34-155-23751
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bazetta Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: MASTERS
License Status: Producing
License Date: 2005-11-25
Spud Date: 2006-02-21
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2006-03-04
Well Total Depth: 5040.00 ft
Configuration: Directional
Latitude: 41.300000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-11-05 Proposed Formations:CLINTON, Issued Date:11/5/2002, Expired Date:11/5/2003 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2003-10-20 Proposed Formations:CLINTON, Issued Date:10/20/2003, Expired Date:10/19/2004 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2004-09-14 Proposed Formations:CLINTON, Issued Date:9/14/2004, Expired Date:9/14/2005 6:00:00 AM, Drilling unit acres:40.36, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-11-25 Proposed Formations:CLINTON, Issued Date:11/25/2005, Expired Date:11/25/2006 6:00:00 AM, Drilling unit acres:40.36, Proposed Well Type:OG, Proposed Well Class:
Original Spud 2006-02-21 RBDMS Rec
Completed 2006-03-04 RBDMS Rec
Reached Total Depth 2006-03-04 RBDMS Rec
Completion Report Received 2006-03-28 RBDMS Rec
Correction to Well 2006-04-21 CHANGE IN TARGET LOCATION: SHOULD BE 1348'SL & 186'WL OF LOT 47; X= 2,480,736; Y= 604,241. CHANGE IN UNIT SIZE T 40.99 ACRES. CHANGE IN QUAD TO "CORTLAND".
Construction Permit Expires 2006-11-25 RBDMS Rec
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-15 4864 4924 95
2006-06-15 4961 4970 19
4864 4924 95
4961 4970 19
4864 4924 95

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1600 Bbl 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 M & M ROYALTY LTD 13641.00 127.00 365
2007 M & M ROYALTY LTD 72637.00 250.00 365
2008 M & M ROYALTY LTD 57952.00 136.00 365
2009 M & M ROYALTY LTD 46518.00 132.00 365
2010 M & M ROYALTY LTD 39950.00 115.00 365
2011 M & M ROYALTY LTD 34409.00 62.00 365
2012 M & M ROYALTY LTD 18727.00 0.00 366
2013 M & M ROYALTY LTD 18651.00 71.00 365
2014 M & M ROYALTY LTD 17814.00 64.00 365
2015 SOUND ENERGY CO INC 10922.00 0.00 305
2016 SOUND ENERGY CO INC 18224.00 47.00 365
2017 SOUND ENERGY CO INC 16686.00 68.00 365
2018 SOUND ENERGY CO INC 17836.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 M & M ROYALTY LTD Brine 70 365
2007 M & M ROYALTY LTD Brine 55 365
2008 M & M ROYALTY LTD Brine 60 365
2009 M & M ROYALTY LTD Brine 55 365
2010 M & M ROYALTY LTD Brine 0 365
2011 M & M ROYALTY LTD Brine 30 365
2012 M & M ROYALTY LTD Brine 0 366
2013 M & M ROYALTY LTD Brine 0 365
2014 M & M ROYALTY LTD Brine 29 365
2015 SOUND ENERGY CO INC Brine 0 305
2016 SOUND ENERGY CO INC Brine 0 365
2017 SOUND ENERGY CO INC Brine 0 365
2018 SOUND ENERGY CO INC Brine 50 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1232658554 2006-2-22 0:00: DD No Violations
-1290662043 2017-6-19 0:00: UP No Violations 0.50
-1657680219 2020-7-29 0:00: UP No Violations
-42152427 2008-8-21 0:00: PL No Violations
-695947471 2011-6-29 0:00: PW No Violations
-801846750 2008-2-14 0:00: PW No Violations
0042152427 2008-08-21 Preliminary Restoration No Violations no violations .
0695947471 2011-06-29 Production Wells No Violations There were no violations at the time of inspection.
0801846750 2008-02-14 Production Wells No Violations no violations .
1130358083 2013-04-10 UrbanProduction Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery contained one, 100 barrel production tank, one, 50 barrel brine tank, and a separator. There was a plug on the load line. There were identification signs at the tank battery and well. The dike was in good condition and capable of containment requirements. A locked chain link fence surrounded the tank battery and well. The proper urban safety equipment was installed on the production tank. The lease road was in good condition and was shared with a Summit Petroleum well; permit number 2-3522.
1232658554 2006-02-22 Drill / Deepen / Reopen Violations Noted Inspection showed there was no fence around drilling pits , also HB stipulations were not posted with drilling permit . Remedial work completed within 2 hours , Violations RESOLVED .
1290662043 2017-06-19 UrbanProduction Wells No Violations I found a new charcoal filter has been installed on the production tank per my request. The chain link fence around the tank battery is secure with a lock.
1405351241 2014-07-11 UrbanProduction Wells No Violations I was on location for a status check inspection. I found during my inspection the well in production with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and a separator. There was a dike surrounding the tank battery. Identification signs were posted at the well and tank battery. There was a plug on the load line. There was a 7 day production chart inside the separator. Locked, chain link fences surrounded the tank battery and well. Safety equipment was installed on the production tank. The lease road was well maintained with crushed limestone.
1713980249 2017-05-02 UrbanProduction Wells No Violations

-up lines have plugs, but no locks. There are locked chain link fences surrounding the well and tank battery. There is landscaping at the tank battery and well. The access road is in good repair.

I spoke with Sound Energy and told them to: Replace the Activated Charcoal Filter. -up lines

A follow-up inspection will be conducted by 5/26/2017.

The equipment on site:



Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1232658554 US-OH-106249 2006-03-19 Failure to comply with permit conditions

For data sources see[9]

References